A New Proton CT Scanner

The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the li...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2016-01
Hauptverfasser: Uzunyan, S A, Blazey, G, Boi, S, Coutrakon, G, Dyshkant, A, Erdelyi, B, Hedin, D, Johnson, E, Krider, J, Rykalin, V, Zutshi, V, d, R, Sellberg, G, Rauch, J E, Roman, M, Rubinov, P, Wilson, P, Naimuddin, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Uzunyan, S A
Blazey, G
Boi, S
Coutrakon, G
Dyshkant, A
Erdelyi, B
Hedin, D
Johnson, E
Krider, J
Rykalin, V
Zutshi, V
d, R
Sellberg, G
Rauch, J E
Roman, M
Rubinov, P
Wilson, P
Naimuddin, M
description The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm\(^2\), for imaging an adult head phantom and reconstructing more accurate RSP values.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2078362846</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2078362846</sourcerecordid><originalsourceid>FETCH-proquest_journals_20783628463</originalsourceid><addsrcrecordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQQd1TwSy1XCCjKL8nPU3AOUQhOTszLSy3iYWBNS8wpTuWF0twMym6uIc4eugVF-YWlqcUl8Vn5pUV5QKl4IwNzC2MzIwsTM2PiVAEAxw4oxg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2078362846</pqid></control><display><type>article</type><title>A New Proton CT Scanner</title><source>Free E- Journals</source><creator>Uzunyan, S A ; Blazey, G ; Boi, S ; Coutrakon, G ; Dyshkant, A ; Erdelyi, B ; Hedin, D ; Johnson, E ; Krider, J ; Rykalin, V ; Zutshi, V ; d, R ; Sellberg, G ; Rauch, J E ; Roman, M ; Rubinov, P ; Wilson, P ; Naimuddin, M</creator><creatorcontrib>Uzunyan, S A ; Blazey, G ; Boi, S ; Coutrakon, G ; Dyshkant, A ; Erdelyi, B ; Hedin, D ; Johnson, E ; Krider, J ; Rykalin, V ; Zutshi, V ; d, R ; Sellberg, G ; Rauch, J E ; Roman, M ; Rubinov, P ; Wilson, P ; Naimuddin, M</creatorcontrib><description>The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm\(^2\), for imaging an adult head phantom and reconstructing more accurate RSP values.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Attenuation coefficients ; Computed tomography ; Dosage ; Protons ; Scanners</subject><ispartof>arXiv.org, 2016-01</ispartof><rights>2016. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>782,786</link.rule.ids></links><search><creatorcontrib>Uzunyan, S A</creatorcontrib><creatorcontrib>Blazey, G</creatorcontrib><creatorcontrib>Boi, S</creatorcontrib><creatorcontrib>Coutrakon, G</creatorcontrib><creatorcontrib>Dyshkant, A</creatorcontrib><creatorcontrib>Erdelyi, B</creatorcontrib><creatorcontrib>Hedin, D</creatorcontrib><creatorcontrib>Johnson, E</creatorcontrib><creatorcontrib>Krider, J</creatorcontrib><creatorcontrib>Rykalin, V</creatorcontrib><creatorcontrib>Zutshi, V</creatorcontrib><creatorcontrib>d, R</creatorcontrib><creatorcontrib>Sellberg, G</creatorcontrib><creatorcontrib>Rauch, J E</creatorcontrib><creatorcontrib>Roman, M</creatorcontrib><creatorcontrib>Rubinov, P</creatorcontrib><creatorcontrib>Wilson, P</creatorcontrib><creatorcontrib>Naimuddin, M</creatorcontrib><title>A New Proton CT Scanner</title><title>arXiv.org</title><description>The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm\(^2\), for imaging an adult head phantom and reconstructing more accurate RSP values.</description><subject>Attenuation coefficients</subject><subject>Computed tomography</subject><subject>Dosage</subject><subject>Protons</subject><subject>Scanners</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQQd1TwSy1XCCjKL8nPU3AOUQhOTszLSy3iYWBNS8wpTuWF0twMym6uIc4eugVF-YWlqcUl8Vn5pUV5QKl4IwNzC2MzIwsTM2PiVAEAxw4oxg</recordid><startdate>20160104</startdate><enddate>20160104</enddate><creator>Uzunyan, S A</creator><creator>Blazey, G</creator><creator>Boi, S</creator><creator>Coutrakon, G</creator><creator>Dyshkant, A</creator><creator>Erdelyi, B</creator><creator>Hedin, D</creator><creator>Johnson, E</creator><creator>Krider, J</creator><creator>Rykalin, V</creator><creator>Zutshi, V</creator><creator>d, R</creator><creator>Sellberg, G</creator><creator>Rauch, J E</creator><creator>Roman, M</creator><creator>Rubinov, P</creator><creator>Wilson, P</creator><creator>Naimuddin, M</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20160104</creationdate><title>A New Proton CT Scanner</title><author>Uzunyan, S A ; Blazey, G ; Boi, S ; Coutrakon, G ; Dyshkant, A ; Erdelyi, B ; Hedin, D ; Johnson, E ; Krider, J ; Rykalin, V ; Zutshi, V ; d, R ; Sellberg, G ; Rauch, J E ; Roman, M ; Rubinov, P ; Wilson, P ; Naimuddin, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_20783628463</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Attenuation coefficients</topic><topic>Computed tomography</topic><topic>Dosage</topic><topic>Protons</topic><topic>Scanners</topic><toplevel>online_resources</toplevel><creatorcontrib>Uzunyan, S A</creatorcontrib><creatorcontrib>Blazey, G</creatorcontrib><creatorcontrib>Boi, S</creatorcontrib><creatorcontrib>Coutrakon, G</creatorcontrib><creatorcontrib>Dyshkant, A</creatorcontrib><creatorcontrib>Erdelyi, B</creatorcontrib><creatorcontrib>Hedin, D</creatorcontrib><creatorcontrib>Johnson, E</creatorcontrib><creatorcontrib>Krider, J</creatorcontrib><creatorcontrib>Rykalin, V</creatorcontrib><creatorcontrib>Zutshi, V</creatorcontrib><creatorcontrib>d, R</creatorcontrib><creatorcontrib>Sellberg, G</creatorcontrib><creatorcontrib>Rauch, J E</creatorcontrib><creatorcontrib>Roman, M</creatorcontrib><creatorcontrib>Rubinov, P</creatorcontrib><creatorcontrib>Wilson, P</creatorcontrib><creatorcontrib>Naimuddin, M</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Uzunyan, S A</au><au>Blazey, G</au><au>Boi, S</au><au>Coutrakon, G</au><au>Dyshkant, A</au><au>Erdelyi, B</au><au>Hedin, D</au><au>Johnson, E</au><au>Krider, J</au><au>Rykalin, V</au><au>Zutshi, V</au><au>d, R</au><au>Sellberg, G</au><au>Rauch, J E</au><au>Roman, M</au><au>Rubinov, P</au><au>Wilson, P</au><au>Naimuddin, M</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>A New Proton CT Scanner</atitle><jtitle>arXiv.org</jtitle><date>2016-01-04</date><risdate>2016</risdate><eissn>2331-8422</eissn><abstract>The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm\(^2\), for imaging an adult head phantom and reconstructing more accurate RSP values.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2016-01
issn 2331-8422
language eng
recordid cdi_proquest_journals_2078362846
source Free E- Journals
subjects Attenuation coefficients
Computed tomography
Dosage
Protons
Scanners
title A New Proton CT Scanner
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T20%3A39%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=A%20New%20Proton%20CT%20Scanner&rft.jtitle=arXiv.org&rft.au=Uzunyan,%20S%20A&rft.date=2016-01-04&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2078362846%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2078362846&rft_id=info:pmid/&rfr_iscdi=true