A Video-Based Method for Objectively Rating Ataxia
For many movement disorders, such as Parkinson's disease and ataxia, disease progression is visually assessed by a clinician using a numerical disease rating scale. These tests are subjective, time-consuming, and must be administered by a professional. This can be problematic where specialists...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2017-09 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Jaroensri, Ronnachai Zhao, Amy Guha Balakrishnan Lo, Derek Schmahmann, Jeremy Guttag, John Durand, Fredo |
description | For many movement disorders, such as Parkinson's disease and ataxia, disease progression is visually assessed by a clinician using a numerical disease rating scale. These tests are subjective, time-consuming, and must be administered by a professional. This can be problematic where specialists are not available, or when a patient is not consistently evaluated by the same clinician. We present an automated method for quantifying the severity of motion impairment in patients with ataxia, using only video recordings. We consider videos of the finger-to-nose test, a common movement task used as part of the assessment of ataxia progression during the course of routine clinical checkups. Our method uses neural network-based pose estimation and optical flow techniques to track the motion of the patient's hand in a video recording. We extract features that describe qualities of the motion such as speed and variation in performance. Using labels provided by an expert clinician, we train a supervised learning model that predicts severity according to the Brief Ataxia Rating Scale (BARS). The performance of our system is comparable to that of a group of ataxia specialists in terms of mean error and correlation, and our system's predictions were consistently within the range of inter-rater variability. This work demonstrates the feasibility of using computer vision and machine learning to produce consistent and clinically useful measures of motor impairment. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2076167205</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2076167205</sourcerecordid><originalsourceid>FETCH-proquest_journals_20761672053</originalsourceid><addsrcrecordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQwclQIy0xJzdd1SixOTVHwTS3JyE9RSMsvUvBPykpNLsksS82pVAhKLMnMS1dwLEmsyEzkYWBNS8wpTuWF0twMym6uIc4eugVF-YWlqcUl8Vn5pUV5QKl4IwNzM0OgVQamxsSpAgBn5DLo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2076167205</pqid></control><display><type>article</type><title>A Video-Based Method for Objectively Rating Ataxia</title><source>Freely Accessible Journals</source><creator>Jaroensri, Ronnachai ; Zhao, Amy ; Guha Balakrishnan ; Lo, Derek ; Schmahmann, Jeremy ; Guttag, John ; Durand, Fredo</creator><creatorcontrib>Jaroensri, Ronnachai ; Zhao, Amy ; Guha Balakrishnan ; Lo, Derek ; Schmahmann, Jeremy ; Guttag, John ; Durand, Fredo</creatorcontrib><description>For many movement disorders, such as Parkinson's disease and ataxia, disease progression is visually assessed by a clinician using a numerical disease rating scale. These tests are subjective, time-consuming, and must be administered by a professional. This can be problematic where specialists are not available, or when a patient is not consistently evaluated by the same clinician. We present an automated method for quantifying the severity of motion impairment in patients with ataxia, using only video recordings. We consider videos of the finger-to-nose test, a common movement task used as part of the assessment of ataxia progression during the course of routine clinical checkups. Our method uses neural network-based pose estimation and optical flow techniques to track the motion of the patient's hand in a video recording. We extract features that describe qualities of the motion such as speed and variation in performance. Using labels provided by an expert clinician, we train a supervised learning model that predicts severity according to the Brief Ataxia Rating Scale (BARS). The performance of our system is comparable to that of a group of ataxia specialists in terms of mean error and correlation, and our system's predictions were consistently within the range of inter-rater variability. This work demonstrates the feasibility of using computer vision and machine learning to produce consistent and clinically useful measures of motor impairment.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Ataxia ; Computer vision ; Feature extraction ; Impairment ; Machine learning ; Mathematical models ; Neural networks ; Optical flow (image analysis) ; Parkinson's disease</subject><ispartof>arXiv.org, 2017-09</ispartof><rights>2017. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>776,780</link.rule.ids></links><search><creatorcontrib>Jaroensri, Ronnachai</creatorcontrib><creatorcontrib>Zhao, Amy</creatorcontrib><creatorcontrib>Guha Balakrishnan</creatorcontrib><creatorcontrib>Lo, Derek</creatorcontrib><creatorcontrib>Schmahmann, Jeremy</creatorcontrib><creatorcontrib>Guttag, John</creatorcontrib><creatorcontrib>Durand, Fredo</creatorcontrib><title>A Video-Based Method for Objectively Rating Ataxia</title><title>arXiv.org</title><description>For many movement disorders, such as Parkinson's disease and ataxia, disease progression is visually assessed by a clinician using a numerical disease rating scale. These tests are subjective, time-consuming, and must be administered by a professional. This can be problematic where specialists are not available, or when a patient is not consistently evaluated by the same clinician. We present an automated method for quantifying the severity of motion impairment in patients with ataxia, using only video recordings. We consider videos of the finger-to-nose test, a common movement task used as part of the assessment of ataxia progression during the course of routine clinical checkups. Our method uses neural network-based pose estimation and optical flow techniques to track the motion of the patient's hand in a video recording. We extract features that describe qualities of the motion such as speed and variation in performance. Using labels provided by an expert clinician, we train a supervised learning model that predicts severity according to the Brief Ataxia Rating Scale (BARS). The performance of our system is comparable to that of a group of ataxia specialists in terms of mean error and correlation, and our system's predictions were consistently within the range of inter-rater variability. This work demonstrates the feasibility of using computer vision and machine learning to produce consistent and clinically useful measures of motor impairment.</description><subject>Ataxia</subject><subject>Computer vision</subject><subject>Feature extraction</subject><subject>Impairment</subject><subject>Machine learning</subject><subject>Mathematical models</subject><subject>Neural networks</subject><subject>Optical flow (image analysis)</subject><subject>Parkinson's disease</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQwclQIy0xJzdd1SixOTVHwTS3JyE9RSMsvUvBPykpNLsksS82pVAhKLMnMS1dwLEmsyEzkYWBNS8wpTuWF0twMym6uIc4eugVF-YWlqcUl8Vn5pUV5QKl4IwNzM0OgVQamxsSpAgBn5DLo</recordid><startdate>20170907</startdate><enddate>20170907</enddate><creator>Jaroensri, Ronnachai</creator><creator>Zhao, Amy</creator><creator>Guha Balakrishnan</creator><creator>Lo, Derek</creator><creator>Schmahmann, Jeremy</creator><creator>Guttag, John</creator><creator>Durand, Fredo</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20170907</creationdate><title>A Video-Based Method for Objectively Rating Ataxia</title><author>Jaroensri, Ronnachai ; Zhao, Amy ; Guha Balakrishnan ; Lo, Derek ; Schmahmann, Jeremy ; Guttag, John ; Durand, Fredo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_20761672053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Ataxia</topic><topic>Computer vision</topic><topic>Feature extraction</topic><topic>Impairment</topic><topic>Machine learning</topic><topic>Mathematical models</topic><topic>Neural networks</topic><topic>Optical flow (image analysis)</topic><topic>Parkinson's disease</topic><toplevel>online_resources</toplevel><creatorcontrib>Jaroensri, Ronnachai</creatorcontrib><creatorcontrib>Zhao, Amy</creatorcontrib><creatorcontrib>Guha Balakrishnan</creatorcontrib><creatorcontrib>Lo, Derek</creatorcontrib><creatorcontrib>Schmahmann, Jeremy</creatorcontrib><creatorcontrib>Guttag, John</creatorcontrib><creatorcontrib>Durand, Fredo</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jaroensri, Ronnachai</au><au>Zhao, Amy</au><au>Guha Balakrishnan</au><au>Lo, Derek</au><au>Schmahmann, Jeremy</au><au>Guttag, John</au><au>Durand, Fredo</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>A Video-Based Method for Objectively Rating Ataxia</atitle><jtitle>arXiv.org</jtitle><date>2017-09-07</date><risdate>2017</risdate><eissn>2331-8422</eissn><abstract>For many movement disorders, such as Parkinson's disease and ataxia, disease progression is visually assessed by a clinician using a numerical disease rating scale. These tests are subjective, time-consuming, and must be administered by a professional. This can be problematic where specialists are not available, or when a patient is not consistently evaluated by the same clinician. We present an automated method for quantifying the severity of motion impairment in patients with ataxia, using only video recordings. We consider videos of the finger-to-nose test, a common movement task used as part of the assessment of ataxia progression during the course of routine clinical checkups. Our method uses neural network-based pose estimation and optical flow techniques to track the motion of the patient's hand in a video recording. We extract features that describe qualities of the motion such as speed and variation in performance. Using labels provided by an expert clinician, we train a supervised learning model that predicts severity according to the Brief Ataxia Rating Scale (BARS). The performance of our system is comparable to that of a group of ataxia specialists in terms of mean error and correlation, and our system's predictions were consistently within the range of inter-rater variability. This work demonstrates the feasibility of using computer vision and machine learning to produce consistent and clinically useful measures of motor impairment.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2017-09 |
issn | 2331-8422 |
language | eng |
recordid | cdi_proquest_journals_2076167205 |
source | Freely Accessible Journals |
subjects | Ataxia Computer vision Feature extraction Impairment Machine learning Mathematical models Neural networks Optical flow (image analysis) Parkinson's disease |
title | A Video-Based Method for Objectively Rating Ataxia |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T19%3A49%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=A%20Video-Based%20Method%20for%20Objectively%20Rating%20Ataxia&rft.jtitle=arXiv.org&rft.au=Jaroensri,%20Ronnachai&rft.date=2017-09-07&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2076167205%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2076167205&rft_id=info:pmid/&rfr_iscdi=true |