Indirect Sliding Mode Control of Power Converters Via Double Integral Sliding Surface
The steady-state regulation error in power converters that use the conventional hysteresis-modulation-based sliding mode controller can be suppressed through the incorporation of an additional integral term of the state variables into the controller. However, it is found that with the indirect type...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 2008-03, Vol.23 (2), p.600-611 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The steady-state regulation error in power converters that use the conventional hysteresis-modulation-based sliding mode controller can be suppressed through the incorporation of an additional integral term of the state variables into the controller. However, it is found that with the indirect type of sliding mode controller (derived based on the equivalent control approach), the same approach of integral sliding mode control is ineffective in alleviating the converter's steady-state error. Moreover, the error increases as the converter's switching frequency decreases. This paper presents an in-depth study of the phenomenon and offers a solution to the problem. Specifically, it is proposed that an additional double-integral term of the controlled variables to be adopted for constructing the sliding surface of indirect sliding mode controllers. Simulation and experimental results are provided for verification. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2007.915624 |