Initial results of a truly pixelated APD-based PET scanner for high-resolution preclinical imaging
Objectives: The LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using fully pixelated detectors and highly integrated parallel front-end processing electronics based on time-to-digital conversion in a dual-threshold Time-over-Threshold (ToT) scheme....
Gespeichert in:
Veröffentlicht in: | The Journal of nuclear medicine (1978) 2017-05, Vol.58, p.91 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | 91 |
container_title | The Journal of nuclear medicine (1978) |
container_volume | 58 |
creator | Gaudin, Emilie Thibaudeau, Christian Arpin, Louis Leroux, Jean-Daniel Beaudoin, Jean-Franois Cadorette, Jules Njejimana, Larissa Samson, Arnaud Bouchard, Jonathan Koua, Konin Fontaine, Réjean Lecomte, Roger |
description | Objectives: The LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using fully pixelated detectors and highly integrated parallel front-end processing electronics based on time-to-digital conversion in a dual-threshold Time-over-Threshold (ToT) scheme. The key objectives of this work are (a) to investigate the detector physical characteristics in this ToT scheme, (b) to assess the imaging performance of the mouse scanner version following the NEMA NU 4-2008 standard, and (c) to demonstrate its unique capability for in vivo imaging in small animals. Methods: The basic detector element uses a 4 x 8 array of 1.12 x 1.12 mm2 Lu1.9Y0.1SiO5:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4 x 8 pixelated monolithic APD array at a pitch of 1.2 mm. Four detector arrays are mounted on an interposer carrying two custom flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was embedded on-chip to encode time and energy information using the dual-threshold ToT scheme. The self-contained 128-channel front-end module was designed as a generic OEM component for ultra-high resolution imaging of small to medium-size animals. The LabPET II mouse scanner consists of 48 front-end modules forming a 78.8-mm diameter by 50.4-mm axial length cylinder, with 32 rings of 192 pixel detectors per ring. The energy, time and intrinsic spatial resolution of the detectors were measured as a function of APD bias and ToT thresholds. Imaging performance data include spatial resolution, absolute sensitivity, count rates, scatter and random fractions, and image quality with phantoms. Images of mice and small rats were obtained using 18F-, 11C-, 64Cu- and 89Zr-based tracers in various static, dynamic and gated imaging protocols. Results: ToT spectra show clearly resolved 511 keV photopeak and Compton edge for each individual pixel. After correction for nonlinear ToT response, energy resolution is typically 22 ± 2% FWHM. Average coincidence time resolution between opposing 128-channel modules is typically 3.3 ± 0.6 ns FWHM. The measured intrinsic spatial resolution obtained by sweeping a 0.3-mm diameter 22Na point source midway between opposite coincident detector arrays was 0.82 ± 0.02 mm FWHM and 1.54 ± 0.05 mm FWTM at a pitch of 1.21 ± 0.01 mm, confirming accurate and distortion-free position measurement, in sharp co |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2039865776</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2039865776</sourcerecordid><originalsourceid>FETCH-proquest_journals_20398657763</originalsourceid><addsrcrecordid>eNqNjMsKwjAURIMoWB__cMF1ILUkjUvxge5cuC9pTeuVmNQ8QP_eLvwAVzNw5syIZDkvOOVClGOSsVzklHPGp2QWwoMxJqSUGanPFiMqA16HZGIA14KC6JP5QI9vbVTUN9he9rRWYWiXwxVCo6zVHlrn4Y7dnQ6uMymis9B73Ri02AyX-FQd2m5BJq0yQS9_OSer4-G6O9Heu1fSIVYPl7wdULVmxUYKXpai-G_1BXlJRsw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2039865776</pqid></control><display><type>article</type><title>Initial results of a truly pixelated APD-based PET scanner for high-resolution preclinical imaging</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Gaudin, Emilie ; Thibaudeau, Christian ; Arpin, Louis ; Leroux, Jean-Daniel ; Beaudoin, Jean-Franois ; Cadorette, Jules ; Njejimana, Larissa ; Samson, Arnaud ; Bouchard, Jonathan ; Koua, Konin ; Fontaine, Réjean ; Lecomte, Roger</creator><creatorcontrib>Gaudin, Emilie ; Thibaudeau, Christian ; Arpin, Louis ; Leroux, Jean-Daniel ; Beaudoin, Jean-Franois ; Cadorette, Jules ; Njejimana, Larissa ; Samson, Arnaud ; Bouchard, Jonathan ; Koua, Konin ; Fontaine, Réjean ; Lecomte, Roger</creatorcontrib><description>Objectives: The LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using fully pixelated detectors and highly integrated parallel front-end processing electronics based on time-to-digital conversion in a dual-threshold Time-over-Threshold (ToT) scheme. The key objectives of this work are (a) to investigate the detector physical characteristics in this ToT scheme, (b) to assess the imaging performance of the mouse scanner version following the NEMA NU 4-2008 standard, and (c) to demonstrate its unique capability for in vivo imaging in small animals. Methods: The basic detector element uses a 4 x 8 array of 1.12 x 1.12 mm2 Lu1.9Y0.1SiO5:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4 x 8 pixelated monolithic APD array at a pitch of 1.2 mm. Four detector arrays are mounted on an interposer carrying two custom flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was embedded on-chip to encode time and energy information using the dual-threshold ToT scheme. The self-contained 128-channel front-end module was designed as a generic OEM component for ultra-high resolution imaging of small to medium-size animals. The LabPET II mouse scanner consists of 48 front-end modules forming a 78.8-mm diameter by 50.4-mm axial length cylinder, with 32 rings of 192 pixel detectors per ring. The energy, time and intrinsic spatial resolution of the detectors were measured as a function of APD bias and ToT thresholds. Imaging performance data include spatial resolution, absolute sensitivity, count rates, scatter and random fractions, and image quality with phantoms. Images of mice and small rats were obtained using 18F-, 11C-, 64Cu- and 89Zr-based tracers in various static, dynamic and gated imaging protocols. Results: ToT spectra show clearly resolved 511 keV photopeak and Compton edge for each individual pixel. After correction for nonlinear ToT response, energy resolution is typically 22 ± 2% FWHM. Average coincidence time resolution between opposing 128-channel modules is typically 3.3 ± 0.6 ns FWHM. The measured intrinsic spatial resolution obtained by sweeping a 0.3-mm diameter 22Na point source midway between opposite coincident detector arrays was 0.82 ± 0.02 mm FWHM and 1.54 ± 0.05 mm FWTM at a pitch of 1.21 ± 0.01 mm, confirming accurate and distortion-free position measurement, in sharp contrast to light-sharing detectors designed for high-resolution PET which are prone to edge distortion. After correction for source size and annihilation photon non-colinearity, the detector geometric resolution is estimated to 0.73 mm FWHM. The system absolute sensitivity is 3% and the maximum noise equivalent count rate (NECR) reaches 367 kcps at 6.5 MBq/cc. Imaging results demonstrate that the 0.8 mm hot spots of a Derenzo phantom can be clearly resolved and that tiny bone structures of the skull, ribs and spine can be delineated in Na18F mouse scans. Cardiac-gated images were obtained in both rats and mice using a high-uptake 18F-labeled metabolic tracer (e.g., 18F-FDG), as well as a high first-pass extraction and rapid washout perfusion tracer (e.g., 11C-acetate). Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed. The small-bore version of the scanner dedicated to mouse and small rat imaging was shown to achieve distortion-free spatial resolution approaching the physical limit of PET.</description><identifier>ISSN: 0161-5505</identifier><identifier>EISSN: 1535-5667</identifier><language>eng</language><publisher>New York: Society of Nuclear Medicine</publisher><subject>Acetic acid ; Acidity ; Animals ; Application specific integrated circuits ; Arrays ; Cylinders ; Data processing ; Detectors ; Distortion ; Electronics ; Energy resolution ; Fluorine isotopes ; High resolution ; Image quality ; Image resolution ; In vivo methods and tests ; Integrated circuits ; Mice ; Modules ; Nuclear medicine ; Perfusion ; Photopeak ; Physical characteristics ; Physical properties ; Pixels ; Positron emission tomography ; Rats ; Rodents ; Scanners ; Scintillation counters ; Sensitivity ; Signal processing ; Sodium channels ; Spatial resolution ; Spine ; Tomography ; Tracers</subject><ispartof>The Journal of nuclear medicine (1978), 2017-05, Vol.58, p.91</ispartof><rights>Copyright Society of Nuclear Medicine May 1, 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Gaudin, Emilie</creatorcontrib><creatorcontrib>Thibaudeau, Christian</creatorcontrib><creatorcontrib>Arpin, Louis</creatorcontrib><creatorcontrib>Leroux, Jean-Daniel</creatorcontrib><creatorcontrib>Beaudoin, Jean-Franois</creatorcontrib><creatorcontrib>Cadorette, Jules</creatorcontrib><creatorcontrib>Njejimana, Larissa</creatorcontrib><creatorcontrib>Samson, Arnaud</creatorcontrib><creatorcontrib>Bouchard, Jonathan</creatorcontrib><creatorcontrib>Koua, Konin</creatorcontrib><creatorcontrib>Fontaine, Réjean</creatorcontrib><creatorcontrib>Lecomte, Roger</creatorcontrib><title>Initial results of a truly pixelated APD-based PET scanner for high-resolution preclinical imaging</title><title>The Journal of nuclear medicine (1978)</title><description>Objectives: The LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using fully pixelated detectors and highly integrated parallel front-end processing electronics based on time-to-digital conversion in a dual-threshold Time-over-Threshold (ToT) scheme. The key objectives of this work are (a) to investigate the detector physical characteristics in this ToT scheme, (b) to assess the imaging performance of the mouse scanner version following the NEMA NU 4-2008 standard, and (c) to demonstrate its unique capability for in vivo imaging in small animals. Methods: The basic detector element uses a 4 x 8 array of 1.12 x 1.12 mm2 Lu1.9Y0.1SiO5:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4 x 8 pixelated monolithic APD array at a pitch of 1.2 mm. Four detector arrays are mounted on an interposer carrying two custom flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was embedded on-chip to encode time and energy information using the dual-threshold ToT scheme. The self-contained 128-channel front-end module was designed as a generic OEM component for ultra-high resolution imaging of small to medium-size animals. The LabPET II mouse scanner consists of 48 front-end modules forming a 78.8-mm diameter by 50.4-mm axial length cylinder, with 32 rings of 192 pixel detectors per ring. The energy, time and intrinsic spatial resolution of the detectors were measured as a function of APD bias and ToT thresholds. Imaging performance data include spatial resolution, absolute sensitivity, count rates, scatter and random fractions, and image quality with phantoms. Images of mice and small rats were obtained using 18F-, 11C-, 64Cu- and 89Zr-based tracers in various static, dynamic and gated imaging protocols. Results: ToT spectra show clearly resolved 511 keV photopeak and Compton edge for each individual pixel. After correction for nonlinear ToT response, energy resolution is typically 22 ± 2% FWHM. Average coincidence time resolution between opposing 128-channel modules is typically 3.3 ± 0.6 ns FWHM. The measured intrinsic spatial resolution obtained by sweeping a 0.3-mm diameter 22Na point source midway between opposite coincident detector arrays was 0.82 ± 0.02 mm FWHM and 1.54 ± 0.05 mm FWTM at a pitch of 1.21 ± 0.01 mm, confirming accurate and distortion-free position measurement, in sharp contrast to light-sharing detectors designed for high-resolution PET which are prone to edge distortion. After correction for source size and annihilation photon non-colinearity, the detector geometric resolution is estimated to 0.73 mm FWHM. The system absolute sensitivity is 3% and the maximum noise equivalent count rate (NECR) reaches 367 kcps at 6.5 MBq/cc. Imaging results demonstrate that the 0.8 mm hot spots of a Derenzo phantom can be clearly resolved and that tiny bone structures of the skull, ribs and spine can be delineated in Na18F mouse scans. Cardiac-gated images were obtained in both rats and mice using a high-uptake 18F-labeled metabolic tracer (e.g., 18F-FDG), as well as a high first-pass extraction and rapid washout perfusion tracer (e.g., 11C-acetate). Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed. The small-bore version of the scanner dedicated to mouse and small rat imaging was shown to achieve distortion-free spatial resolution approaching the physical limit of PET.</description><subject>Acetic acid</subject><subject>Acidity</subject><subject>Animals</subject><subject>Application specific integrated circuits</subject><subject>Arrays</subject><subject>Cylinders</subject><subject>Data processing</subject><subject>Detectors</subject><subject>Distortion</subject><subject>Electronics</subject><subject>Energy resolution</subject><subject>Fluorine isotopes</subject><subject>High resolution</subject><subject>Image quality</subject><subject>Image resolution</subject><subject>In vivo methods and tests</subject><subject>Integrated circuits</subject><subject>Mice</subject><subject>Modules</subject><subject>Nuclear medicine</subject><subject>Perfusion</subject><subject>Photopeak</subject><subject>Physical characteristics</subject><subject>Physical properties</subject><subject>Pixels</subject><subject>Positron emission tomography</subject><subject>Rats</subject><subject>Rodents</subject><subject>Scanners</subject><subject>Scintillation counters</subject><subject>Sensitivity</subject><subject>Signal processing</subject><subject>Sodium channels</subject><subject>Spatial resolution</subject><subject>Spine</subject><subject>Tomography</subject><subject>Tracers</subject><issn>0161-5505</issn><issn>1535-5667</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqNjMsKwjAURIMoWB__cMF1ILUkjUvxge5cuC9pTeuVmNQ8QP_eLvwAVzNw5syIZDkvOOVClGOSsVzklHPGp2QWwoMxJqSUGanPFiMqA16HZGIA14KC6JP5QI9vbVTUN9he9rRWYWiXwxVCo6zVHlrn4Y7dnQ6uMymis9B73Ri02AyX-FQd2m5BJq0yQS9_OSer4-G6O9Heu1fSIVYPl7wdULVmxUYKXpai-G_1BXlJRsw</recordid><startdate>20170501</startdate><enddate>20170501</enddate><creator>Gaudin, Emilie</creator><creator>Thibaudeau, Christian</creator><creator>Arpin, Louis</creator><creator>Leroux, Jean-Daniel</creator><creator>Beaudoin, Jean-Franois</creator><creator>Cadorette, Jules</creator><creator>Njejimana, Larissa</creator><creator>Samson, Arnaud</creator><creator>Bouchard, Jonathan</creator><creator>Koua, Konin</creator><creator>Fontaine, Réjean</creator><creator>Lecomte, Roger</creator><general>Society of Nuclear Medicine</general><scope>4T-</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>NAPCQ</scope><scope>P64</scope></search><sort><creationdate>20170501</creationdate><title>Initial results of a truly pixelated APD-based PET scanner for high-resolution preclinical imaging</title><author>Gaudin, Emilie ; Thibaudeau, Christian ; Arpin, Louis ; Leroux, Jean-Daniel ; Beaudoin, Jean-Franois ; Cadorette, Jules ; Njejimana, Larissa ; Samson, Arnaud ; Bouchard, Jonathan ; Koua, Konin ; Fontaine, Réjean ; Lecomte, Roger</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_20398657763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Acetic acid</topic><topic>Acidity</topic><topic>Animals</topic><topic>Application specific integrated circuits</topic><topic>Arrays</topic><topic>Cylinders</topic><topic>Data processing</topic><topic>Detectors</topic><topic>Distortion</topic><topic>Electronics</topic><topic>Energy resolution</topic><topic>Fluorine isotopes</topic><topic>High resolution</topic><topic>Image quality</topic><topic>Image resolution</topic><topic>In vivo methods and tests</topic><topic>Integrated circuits</topic><topic>Mice</topic><topic>Modules</topic><topic>Nuclear medicine</topic><topic>Perfusion</topic><topic>Photopeak</topic><topic>Physical characteristics</topic><topic>Physical properties</topic><topic>Pixels</topic><topic>Positron emission tomography</topic><topic>Rats</topic><topic>Rodents</topic><topic>Scanners</topic><topic>Scintillation counters</topic><topic>Sensitivity</topic><topic>Signal processing</topic><topic>Sodium channels</topic><topic>Spatial resolution</topic><topic>Spine</topic><topic>Tomography</topic><topic>Tracers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gaudin, Emilie</creatorcontrib><creatorcontrib>Thibaudeau, Christian</creatorcontrib><creatorcontrib>Arpin, Louis</creatorcontrib><creatorcontrib>Leroux, Jean-Daniel</creatorcontrib><creatorcontrib>Beaudoin, Jean-Franois</creatorcontrib><creatorcontrib>Cadorette, Jules</creatorcontrib><creatorcontrib>Njejimana, Larissa</creatorcontrib><creatorcontrib>Samson, Arnaud</creatorcontrib><creatorcontrib>Bouchard, Jonathan</creatorcontrib><creatorcontrib>Koua, Konin</creatorcontrib><creatorcontrib>Fontaine, Réjean</creatorcontrib><creatorcontrib>Lecomte, Roger</creatorcontrib><collection>Docstoc</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Nursing & Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>The Journal of nuclear medicine (1978)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gaudin, Emilie</au><au>Thibaudeau, Christian</au><au>Arpin, Louis</au><au>Leroux, Jean-Daniel</au><au>Beaudoin, Jean-Franois</au><au>Cadorette, Jules</au><au>Njejimana, Larissa</au><au>Samson, Arnaud</au><au>Bouchard, Jonathan</au><au>Koua, Konin</au><au>Fontaine, Réjean</au><au>Lecomte, Roger</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Initial results of a truly pixelated APD-based PET scanner for high-resolution preclinical imaging</atitle><jtitle>The Journal of nuclear medicine (1978)</jtitle><date>2017-05-01</date><risdate>2017</risdate><volume>58</volume><spage>91</spage><pages>91-</pages><issn>0161-5505</issn><eissn>1535-5667</eissn><abstract>Objectives: The LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using fully pixelated detectors and highly integrated parallel front-end processing electronics based on time-to-digital conversion in a dual-threshold Time-over-Threshold (ToT) scheme. The key objectives of this work are (a) to investigate the detector physical characteristics in this ToT scheme, (b) to assess the imaging performance of the mouse scanner version following the NEMA NU 4-2008 standard, and (c) to demonstrate its unique capability for in vivo imaging in small animals. Methods: The basic detector element uses a 4 x 8 array of 1.12 x 1.12 mm2 Lu1.9Y0.1SiO5:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4 x 8 pixelated monolithic APD array at a pitch of 1.2 mm. Four detector arrays are mounted on an interposer carrying two custom flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was embedded on-chip to encode time and energy information using the dual-threshold ToT scheme. The self-contained 128-channel front-end module was designed as a generic OEM component for ultra-high resolution imaging of small to medium-size animals. The LabPET II mouse scanner consists of 48 front-end modules forming a 78.8-mm diameter by 50.4-mm axial length cylinder, with 32 rings of 192 pixel detectors per ring. The energy, time and intrinsic spatial resolution of the detectors were measured as a function of APD bias and ToT thresholds. Imaging performance data include spatial resolution, absolute sensitivity, count rates, scatter and random fractions, and image quality with phantoms. Images of mice and small rats were obtained using 18F-, 11C-, 64Cu- and 89Zr-based tracers in various static, dynamic and gated imaging protocols. Results: ToT spectra show clearly resolved 511 keV photopeak and Compton edge for each individual pixel. After correction for nonlinear ToT response, energy resolution is typically 22 ± 2% FWHM. Average coincidence time resolution between opposing 128-channel modules is typically 3.3 ± 0.6 ns FWHM. The measured intrinsic spatial resolution obtained by sweeping a 0.3-mm diameter 22Na point source midway between opposite coincident detector arrays was 0.82 ± 0.02 mm FWHM and 1.54 ± 0.05 mm FWTM at a pitch of 1.21 ± 0.01 mm, confirming accurate and distortion-free position measurement, in sharp contrast to light-sharing detectors designed for high-resolution PET which are prone to edge distortion. After correction for source size and annihilation photon non-colinearity, the detector geometric resolution is estimated to 0.73 mm FWHM. The system absolute sensitivity is 3% and the maximum noise equivalent count rate (NECR) reaches 367 kcps at 6.5 MBq/cc. Imaging results demonstrate that the 0.8 mm hot spots of a Derenzo phantom can be clearly resolved and that tiny bone structures of the skull, ribs and spine can be delineated in Na18F mouse scans. Cardiac-gated images were obtained in both rats and mice using a high-uptake 18F-labeled metabolic tracer (e.g., 18F-FDG), as well as a high first-pass extraction and rapid washout perfusion tracer (e.g., 11C-acetate). Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed. The small-bore version of the scanner dedicated to mouse and small rat imaging was shown to achieve distortion-free spatial resolution approaching the physical limit of PET.</abstract><cop>New York</cop><pub>Society of Nuclear Medicine</pub></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0161-5505 |
ispartof | The Journal of nuclear medicine (1978), 2017-05, Vol.58, p.91 |
issn | 0161-5505 1535-5667 |
language | eng |
recordid | cdi_proquest_journals_2039865776 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection |
subjects | Acetic acid Acidity Animals Application specific integrated circuits Arrays Cylinders Data processing Detectors Distortion Electronics Energy resolution Fluorine isotopes High resolution Image quality Image resolution In vivo methods and tests Integrated circuits Mice Modules Nuclear medicine Perfusion Photopeak Physical characteristics Physical properties Pixels Positron emission tomography Rats Rodents Scanners Scintillation counters Sensitivity Signal processing Sodium channels Spatial resolution Spine Tomography Tracers |
title | Initial results of a truly pixelated APD-based PET scanner for high-resolution preclinical imaging |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T22%3A36%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Initial%20results%20of%20a%20truly%20pixelated%20APD-based%20PET%20scanner%20for%20high-resolution%20preclinical%20imaging&rft.jtitle=The%20Journal%20of%20nuclear%20medicine%20(1978)&rft.au=Gaudin,%20Emilie&rft.date=2017-05-01&rft.volume=58&rft.spage=91&rft.pages=91-&rft.issn=0161-5505&rft.eissn=1535-5667&rft_id=info:doi/&rft_dat=%3Cproquest%3E2039865776%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2039865776&rft_id=info:pmid/&rfr_iscdi=true |