EFECTO DE LA ALTURA DEL MANGUITO EN UNIONES SOLDADAS EN CAÑERÍAS DE COBRE/BUSHING HEIGHT EFFECT IN SOLDERED COPPER PIPE JOINTS
Copper tubes were drilled with thermal flow drilling. Conventional HSS drills diameters were used to make pre drilling holes. Different height bushings were made. Two of the bushing heights were selected. The bushing circularity was measured. A ø 12,7 mm tube was welded perpendicularly on a ø 28,6 m...
Gespeichert in:
Veröffentlicht in: | Ingeniare : Revista Chilena de Ingenieria 2006-09, Vol.14 (3), p.245 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | spa |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Copper tubes were drilled with thermal flow drilling. Conventional HSS drills diameters were used to make pre drilling holes. Different height bushings were made. Two of the bushing heights were selected. The bushing circularity was measured. A ø 12,7 mm tube was welded perpendicularly on a ø 28,6 mm tube. A especial support device was designed and it was adapted to the Universal Test Machine, to determine the tensile stress of the brazing joint. The micro hardness and metallographic test were made in the brazing zone. As a conclusion the lower height bushing is enough to reach the maximum resistance. [PUBLICATION ABSTRACT] |
---|---|
ISSN: | 0718-3291 0718-3305 |