EFECTO DE LA ALTURA DEL MANGUITO EN UNIONES SOLDADAS EN CAÑERÍAS DE COBRE/BUSHING HEIGHT EFFECT IN SOLDERED COPPER PIPE JOINTS

Copper tubes were drilled with thermal flow drilling. Conventional HSS drills diameters were used to make pre drilling holes. Different height bushings were made. Two of the bushing heights were selected. The bushing circularity was measured. A ø 12,7 mm tube was welded perpendicularly on a ø 28,6 m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ingeniare : Revista Chilena de Ingenieria 2006-09, Vol.14 (3), p.245
Hauptverfasser: Carmona, Víctor, Vergara, Jorge D, Godoy, Juan Miguel R
Format: Artikel
Sprache:spa
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Copper tubes were drilled with thermal flow drilling. Conventional HSS drills diameters were used to make pre drilling holes. Different height bushings were made. Two of the bushing heights were selected. The bushing circularity was measured. A ø 12,7 mm tube was welded perpendicularly on a ø 28,6 mm tube. A especial support device was designed and it was adapted to the Universal Test Machine, to determine the tensile stress of the brazing joint. The micro hardness and metallographic test were made in the brazing zone. As a conclusion the lower height bushing is enough to reach the maximum resistance. [PUBLICATION ABSTRACT]
ISSN:0718-3291
0718-3305