Peculiarities of Changes in the Desired Signal of a Magnetic Anisometer under Rotation of Its Attachable Sensor

The way the rotation and speed of the sensor in a permanent-magnet anisometer affect its readings when inspecting the stress-strained state of ferromagnetic articles has been studied. Regularities of changes in the longitudinal and transverse magnetic-field strength components during sensor rotation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Russian journal of nondestructive testing 2018, Vol.54 (1), p.65-69
Hauptverfasser: Zakharov, V. A., Molin, S. M., Len’kov, S. V., Kolyasev, V. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The way the rotation and speed of the sensor in a permanent-magnet anisometer affect its readings when inspecting the stress-strained state of ferromagnetic articles has been studied. Regularities of changes in the longitudinal and transverse magnetic-field strength components during sensor rotation have been revealed. A degree to which both components depend on the rotation speed has been demonstrated.
ISSN:1061-8309
1608-3385
DOI:10.1134/S1061830918010102