A novel sensor to measure the biased pulse magnetic response in steel stay cable for the detection of surface and internal flaws

•Biased pulse magnetic response in steel stay cable are measured for flaws assessment.•The novel sensor possess the characters of flexibility and low power consumption.•Both the surface notches and internal broken wire flaws in the cable is detectable. A new type of sensor is designed to measure the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. A. Physical. 2018-01, Vol.269, p.218-226
Hauptverfasser: Liu, Xiucheng, Xiao, Junwu, Wu, Bin, He, Cunfu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 226
container_issue
container_start_page 218
container_title Sensors and actuators. A. Physical.
container_volume 269
creator Liu, Xiucheng
Xiao, Junwu
Wu, Bin
He, Cunfu
description •Biased pulse magnetic response in steel stay cable are measured for flaws assessment.•The novel sensor possess the characters of flexibility and low power consumption.•Both the surface notches and internal broken wire flaws in the cable is detectable. A new type of sensor is designed to measure the biased pulse magnetic response in a large-diameter steel stay cable for the assessment of both surface and internal flaws. The sensor deploys two parallel-connected flexible flat coils (FFC) fed with a biased pulse current as the electromagnet for cable magnetization. A tunnel magneto-resistive (TMR) device and two series-connected sensing coils are used to measure the surface magnetic flux leakage (MFL) and the main-flux variation in the defective cable, respectively. A comparative study between the weak and near-saturated magnetization states of a defective cable is performed by finite element simulation tools to investigate the flaw detection ability of both the surface MFL and main-flux measurement methods With the optimized implementation plan and installation locations of the magnetic sensing elements, a prototype of the sensor and a biased pulse current supply is developed for proof-of-concept experiments. The MFL induced by a surface wire notch with the minimal size of 2mm in width and 1mm in depth can be detected by the TMR device with a lift-off distance of 8mm to the notch. To achieve the quantitative evaluation of multiple internal broken wires (MIBW), main-flux measurements are applied to reveal the effect of the MIBW flaws on the estimated magnetic induction intensity of the cable. The approximate linear dependency of the magnetic induction intensity on the loss rate of the cross-section area can be concluded at the rising and falling edges of the pulsed current. The maximum magnetic induction intensity may act as the feature parameter to characterize the extent of the MIBW flaws with the high accuracy. Compared with the traditional yoke magnetizing sensor, the novel sensor utilizing the FFCs improves the detection flexibility and decreases the weight. The application of the biased pulse current not only reduces the power consumption for coil heating during long-term inspection but also allows the sensor to detect both the surface and internal flaws in the cables.
doi_str_mv 10.1016/j.sna.2017.11.005
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2010776073</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0924424717313250</els_id><sourcerecordid>2010776073</sourcerecordid><originalsourceid>FETCH-LOGICAL-c325t-fc51b49489f1a80a8829d2eaa81e95a40b6e093ae73caff21c5920802a4c00dc3</originalsourceid><addsrcrecordid>eNp9kEFrGzEQhUVooG6SH9CboOfdjKRda5eejGmSgqGX9izG2lEqs5YcSU7JLT-9WtxzTwPD-x6Pj7HPAloBYn1_aHPAVoLQrRAtQH_FVmLQqlGwHj-wFYyyazrZ6Y_sU84HAFBK6xV73_AQX2nmmUKOiZfIj4T5nIiX38T3HjNN_HSeM_EjPgcq3vJE-RRD_fjAc6GFLvjGLe5n4m5pqehEhWzxMfDoeC10aIljmCpUKAWcuZvxT75l1w5r-92_e8N-PXz7uX1qdj8ev283u8Yq2ZfG2V7su7EbRidwABwGOU6SEAdBY48d7NcEo0LSyqJzUth-lDCAxM4CTFbdsC-X3lOKL2fKxRzieZmRTbUGWq9Bq5oSl5RNMedEzpySP2J6MwLMItocTBW9INoIYaroyny9MFTnv3pKJltPwdLkUzVgpuj_Q_8FcPaHiA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2010776073</pqid></control><display><type>article</type><title>A novel sensor to measure the biased pulse magnetic response in steel stay cable for the detection of surface and internal flaws</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Liu, Xiucheng ; Xiao, Junwu ; Wu, Bin ; He, Cunfu</creator><creatorcontrib>Liu, Xiucheng ; Xiao, Junwu ; Wu, Bin ; He, Cunfu</creatorcontrib><description>•Biased pulse magnetic response in steel stay cable are measured for flaws assessment.•The novel sensor possess the characters of flexibility and low power consumption.•Both the surface notches and internal broken wire flaws in the cable is detectable. A new type of sensor is designed to measure the biased pulse magnetic response in a large-diameter steel stay cable for the assessment of both surface and internal flaws. The sensor deploys two parallel-connected flexible flat coils (FFC) fed with a biased pulse current as the electromagnet for cable magnetization. A tunnel magneto-resistive (TMR) device and two series-connected sensing coils are used to measure the surface magnetic flux leakage (MFL) and the main-flux variation in the defective cable, respectively. A comparative study between the weak and near-saturated magnetization states of a defective cable is performed by finite element simulation tools to investigate the flaw detection ability of both the surface MFL and main-flux measurement methods With the optimized implementation plan and installation locations of the magnetic sensing elements, a prototype of the sensor and a biased pulse current supply is developed for proof-of-concept experiments. The MFL induced by a surface wire notch with the minimal size of 2mm in width and 1mm in depth can be detected by the TMR device with a lift-off distance of 8mm to the notch. To achieve the quantitative evaluation of multiple internal broken wires (MIBW), main-flux measurements are applied to reveal the effect of the MIBW flaws on the estimated magnetic induction intensity of the cable. The approximate linear dependency of the magnetic induction intensity on the loss rate of the cross-section area can be concluded at the rising and falling edges of the pulsed current. The maximum magnetic induction intensity may act as the feature parameter to characterize the extent of the MIBW flaws with the high accuracy. Compared with the traditional yoke magnetizing sensor, the novel sensor utilizing the FFCs improves the detection flexibility and decreases the weight. The application of the biased pulse current not only reduces the power consumption for coil heating during long-term inspection but also allows the sensor to detect both the surface and internal flaws in the cables.</description><identifier>ISSN: 0924-4247</identifier><identifier>EISSN: 1873-3069</identifier><identifier>DOI: 10.1016/j.sna.2017.11.005</identifier><language>eng</language><publisher>Lausanne: Elsevier B.V</publisher><subject>Bias ; Biased pulse current ; Cables ; Coiling ; Coils ; Electrical equipment ; Finite element method ; Flaw assessment ; Inspection ; Magnetic flux ; Magnetic induction ; Magnetization ; Main-flux measurement ; Measurement methods ; Measurement techniques ; Nondestructive testing ; Power consumption ; Pulsed current ; Quantitative analysis ; Sensors ; Steel stay cable ; Studies ; Surface magnetic flux leakage ; Weight reduction</subject><ispartof>Sensors and actuators. A. Physical., 2018-01, Vol.269, p.218-226</ispartof><rights>2017 Elsevier B.V.</rights><rights>Copyright Elsevier BV Jan 1, 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c325t-fc51b49489f1a80a8829d2eaa81e95a40b6e093ae73caff21c5920802a4c00dc3</citedby><cites>FETCH-LOGICAL-c325t-fc51b49489f1a80a8829d2eaa81e95a40b6e093ae73caff21c5920802a4c00dc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.sna.2017.11.005$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,781,785,3551,27929,27930,46000</link.rule.ids></links><search><creatorcontrib>Liu, Xiucheng</creatorcontrib><creatorcontrib>Xiao, Junwu</creatorcontrib><creatorcontrib>Wu, Bin</creatorcontrib><creatorcontrib>He, Cunfu</creatorcontrib><title>A novel sensor to measure the biased pulse magnetic response in steel stay cable for the detection of surface and internal flaws</title><title>Sensors and actuators. A. Physical.</title><description>•Biased pulse magnetic response in steel stay cable are measured for flaws assessment.•The novel sensor possess the characters of flexibility and low power consumption.•Both the surface notches and internal broken wire flaws in the cable is detectable. A new type of sensor is designed to measure the biased pulse magnetic response in a large-diameter steel stay cable for the assessment of both surface and internal flaws. The sensor deploys two parallel-connected flexible flat coils (FFC) fed with a biased pulse current as the electromagnet for cable magnetization. A tunnel magneto-resistive (TMR) device and two series-connected sensing coils are used to measure the surface magnetic flux leakage (MFL) and the main-flux variation in the defective cable, respectively. A comparative study between the weak and near-saturated magnetization states of a defective cable is performed by finite element simulation tools to investigate the flaw detection ability of both the surface MFL and main-flux measurement methods With the optimized implementation plan and installation locations of the magnetic sensing elements, a prototype of the sensor and a biased pulse current supply is developed for proof-of-concept experiments. The MFL induced by a surface wire notch with the minimal size of 2mm in width and 1mm in depth can be detected by the TMR device with a lift-off distance of 8mm to the notch. To achieve the quantitative evaluation of multiple internal broken wires (MIBW), main-flux measurements are applied to reveal the effect of the MIBW flaws on the estimated magnetic induction intensity of the cable. The approximate linear dependency of the magnetic induction intensity on the loss rate of the cross-section area can be concluded at the rising and falling edges of the pulsed current. The maximum magnetic induction intensity may act as the feature parameter to characterize the extent of the MIBW flaws with the high accuracy. Compared with the traditional yoke magnetizing sensor, the novel sensor utilizing the FFCs improves the detection flexibility and decreases the weight. The application of the biased pulse current not only reduces the power consumption for coil heating during long-term inspection but also allows the sensor to detect both the surface and internal flaws in the cables.</description><subject>Bias</subject><subject>Biased pulse current</subject><subject>Cables</subject><subject>Coiling</subject><subject>Coils</subject><subject>Electrical equipment</subject><subject>Finite element method</subject><subject>Flaw assessment</subject><subject>Inspection</subject><subject>Magnetic flux</subject><subject>Magnetic induction</subject><subject>Magnetization</subject><subject>Main-flux measurement</subject><subject>Measurement methods</subject><subject>Measurement techniques</subject><subject>Nondestructive testing</subject><subject>Power consumption</subject><subject>Pulsed current</subject><subject>Quantitative analysis</subject><subject>Sensors</subject><subject>Steel stay cable</subject><subject>Studies</subject><subject>Surface magnetic flux leakage</subject><subject>Weight reduction</subject><issn>0924-4247</issn><issn>1873-3069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kEFrGzEQhUVooG6SH9CboOfdjKRda5eejGmSgqGX9izG2lEqs5YcSU7JLT-9WtxzTwPD-x6Pj7HPAloBYn1_aHPAVoLQrRAtQH_FVmLQqlGwHj-wFYyyazrZ6Y_sU84HAFBK6xV73_AQX2nmmUKOiZfIj4T5nIiX38T3HjNN_HSeM_EjPgcq3vJE-RRD_fjAc6GFLvjGLe5n4m5pqehEhWzxMfDoeC10aIljmCpUKAWcuZvxT75l1w5r-92_e8N-PXz7uX1qdj8ev283u8Yq2ZfG2V7su7EbRidwABwGOU6SEAdBY48d7NcEo0LSyqJzUth-lDCAxM4CTFbdsC-X3lOKL2fKxRzieZmRTbUGWq9Bq5oSl5RNMedEzpySP2J6MwLMItocTBW9INoIYaroyny9MFTnv3pKJltPwdLkUzVgpuj_Q_8FcPaHiA</recordid><startdate>20180101</startdate><enddate>20180101</enddate><creator>Liu, Xiucheng</creator><creator>Xiao, Junwu</creator><creator>Wu, Bin</creator><creator>He, Cunfu</creator><general>Elsevier B.V</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20180101</creationdate><title>A novel sensor to measure the biased pulse magnetic response in steel stay cable for the detection of surface and internal flaws</title><author>Liu, Xiucheng ; Xiao, Junwu ; Wu, Bin ; He, Cunfu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c325t-fc51b49489f1a80a8829d2eaa81e95a40b6e093ae73caff21c5920802a4c00dc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Bias</topic><topic>Biased pulse current</topic><topic>Cables</topic><topic>Coiling</topic><topic>Coils</topic><topic>Electrical equipment</topic><topic>Finite element method</topic><topic>Flaw assessment</topic><topic>Inspection</topic><topic>Magnetic flux</topic><topic>Magnetic induction</topic><topic>Magnetization</topic><topic>Main-flux measurement</topic><topic>Measurement methods</topic><topic>Measurement techniques</topic><topic>Nondestructive testing</topic><topic>Power consumption</topic><topic>Pulsed current</topic><topic>Quantitative analysis</topic><topic>Sensors</topic><topic>Steel stay cable</topic><topic>Studies</topic><topic>Surface magnetic flux leakage</topic><topic>Weight reduction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liu, Xiucheng</creatorcontrib><creatorcontrib>Xiao, Junwu</creatorcontrib><creatorcontrib>Wu, Bin</creatorcontrib><creatorcontrib>He, Cunfu</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. A. Physical.</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Liu, Xiucheng</au><au>Xiao, Junwu</au><au>Wu, Bin</au><au>He, Cunfu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A novel sensor to measure the biased pulse magnetic response in steel stay cable for the detection of surface and internal flaws</atitle><jtitle>Sensors and actuators. A. Physical.</jtitle><date>2018-01-01</date><risdate>2018</risdate><volume>269</volume><spage>218</spage><epage>226</epage><pages>218-226</pages><issn>0924-4247</issn><eissn>1873-3069</eissn><abstract>•Biased pulse magnetic response in steel stay cable are measured for flaws assessment.•The novel sensor possess the characters of flexibility and low power consumption.•Both the surface notches and internal broken wire flaws in the cable is detectable. A new type of sensor is designed to measure the biased pulse magnetic response in a large-diameter steel stay cable for the assessment of both surface and internal flaws. The sensor deploys two parallel-connected flexible flat coils (FFC) fed with a biased pulse current as the electromagnet for cable magnetization. A tunnel magneto-resistive (TMR) device and two series-connected sensing coils are used to measure the surface magnetic flux leakage (MFL) and the main-flux variation in the defective cable, respectively. A comparative study between the weak and near-saturated magnetization states of a defective cable is performed by finite element simulation tools to investigate the flaw detection ability of both the surface MFL and main-flux measurement methods With the optimized implementation plan and installation locations of the magnetic sensing elements, a prototype of the sensor and a biased pulse current supply is developed for proof-of-concept experiments. The MFL induced by a surface wire notch with the minimal size of 2mm in width and 1mm in depth can be detected by the TMR device with a lift-off distance of 8mm to the notch. To achieve the quantitative evaluation of multiple internal broken wires (MIBW), main-flux measurements are applied to reveal the effect of the MIBW flaws on the estimated magnetic induction intensity of the cable. The approximate linear dependency of the magnetic induction intensity on the loss rate of the cross-section area can be concluded at the rising and falling edges of the pulsed current. The maximum magnetic induction intensity may act as the feature parameter to characterize the extent of the MIBW flaws with the high accuracy. Compared with the traditional yoke magnetizing sensor, the novel sensor utilizing the FFCs improves the detection flexibility and decreases the weight. The application of the biased pulse current not only reduces the power consumption for coil heating during long-term inspection but also allows the sensor to detect both the surface and internal flaws in the cables.</abstract><cop>Lausanne</cop><pub>Elsevier B.V</pub><doi>10.1016/j.sna.2017.11.005</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0924-4247
ispartof Sensors and actuators. A. Physical., 2018-01, Vol.269, p.218-226
issn 0924-4247
1873-3069
language eng
recordid cdi_proquest_journals_2010776073
source ScienceDirect Journals (5 years ago - present)
subjects Bias
Biased pulse current
Cables
Coiling
Coils
Electrical equipment
Finite element method
Flaw assessment
Inspection
Magnetic flux
Magnetic induction
Magnetization
Main-flux measurement
Measurement methods
Measurement techniques
Nondestructive testing
Power consumption
Pulsed current
Quantitative analysis
Sensors
Steel stay cable
Studies
Surface magnetic flux leakage
Weight reduction
title A novel sensor to measure the biased pulse magnetic response in steel stay cable for the detection of surface and internal flaws
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T11%3A50%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20novel%20sensor%20to%20measure%20the%20biased%20pulse%20magnetic%20response%20in%20steel%20stay%20cable%20for%20the%20detection%20of%20surface%20and%20internal%20flaws&rft.jtitle=Sensors%20and%20actuators.%20A.%20Physical.&rft.au=Liu,%20Xiucheng&rft.date=2018-01-01&rft.volume=269&rft.spage=218&rft.epage=226&rft.pages=218-226&rft.issn=0924-4247&rft.eissn=1873-3069&rft_id=info:doi/10.1016/j.sna.2017.11.005&rft_dat=%3Cproquest_cross%3E2010776073%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2010776073&rft_id=info:pmid/&rft_els_id=S0924424717313250&rfr_iscdi=true