Examination of Systematic Bench Errors for Calibration of a Strain-Gauge Balance

We present a schematic diagram of the automated calibration stand 6GS-40M intended for calibration of an intra- and out-of-model six-component strain-gauge balance. The basic features of the stand construction are stated and its elastic model is constructed. The main sources of the occurrence of sys...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement techniques 2017-11, Vol.60 (8), p.763-770
Hauptverfasser: Bol’shakova, A. A., Volobuev, V. S., Gorbushin, A. R., Petronevich, V. V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We present a schematic diagram of the automated calibration stand 6GS-40M intended for calibration of an intra- and out-of-model six-component strain-gauge balance. The basic features of the stand construction are stated and its elastic model is constructed. The main sources of the occurrence of systematic errors in weights are considered. A technique for calculating the movement of the origin of the stand during the calibration of the balance is described. A technique for calculating loads in the Earth coordinate system is described by recording the equation of equilibrium of forces for an arbitrary position of the calibration device in space.
ISSN:0543-1972
1573-8906