Life cycle climate performance evaluation (LCCP) on cooling and heating systems in South Korea
•A new LCCP model is developed and applied to selected Korean cities.•Application of heat pumps can reduce total CO2 emissions up to 9.6% (vs. gas boiler).•Application of heat pumps with R290 reduces total CO2 emissions up to 22.3%.•Vapor injection cycle with R290 can reduce the emission up to 35%....
Gespeichert in:
Veröffentlicht in: | Applied thermal engineering 2017-06, Vol.120, p.88-98 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 98 |
---|---|
container_issue | |
container_start_page | 88 |
container_title | Applied thermal engineering |
container_volume | 120 |
creator | Choi, Seyoung Oh, Jinwoo Hwang, Yunho Lee, Hoseong |
description | •A new LCCP model is developed and applied to selected Korean cities.•Application of heat pumps can reduce total CO2 emissions up to 9.6% (vs. gas boiler).•Application of heat pumps with R290 reduces total CO2 emissions up to 22.3%.•Vapor injection cycle with R290 can reduce the emission up to 35%.
In this study, a life cycle climate performance (LCCP) of cooling and heating systems is developed and evaluated for South Korean weather conditions. While a heat pump is widely used for both space cooling and heating in United States, the heat pump is only used for space cooling and a gas boiler is used instead for space heating in South Korea. Therefore, LCCP evaluation method is extended with the gas boiler. The evaluation results show that the use of the heat pump for space heating can reduce CO2 emissions by 11–17%. Moreover, various low global warming potential (GWP) refrigerants, cycle options and weather conditions are applied and evaluated. Low GWP refrigerants reduce the direct emissions by decreasing the charging amount compared to R410A. In case of using R290, total CO2 emissions are reduced by 19–22%. The vapor injection cycle with a flash tank with R410A improves energy efficiency and it reduces CO2 emissions by 7–10%. Applying the VI cycle with R32 or R290, the total emissions are reduced by 27–35%. |
doi_str_mv | 10.1016/j.applthermaleng.2017.03.105 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1932187340</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1359431116334512</els_id><sourcerecordid>1932187340</sourcerecordid><originalsourceid>FETCH-LOGICAL-c399t-d01f1d2d33bc18bd9d9191b993db913bd8040b3e2dc1e191af1593bca452f443</originalsourceid><addsrcrecordid>eNqNkFFLwzAUhYsoOKf_IaAP-tCa27RbA77IcCoWFNyzIU1ut5SuqUk72L83Y7745kty4Jx7LveLohugCVCY3TeJ7Pt22KDbyha7dZJSmCeUBTc_iSZQzFmcz-jsNGiW8zhjAOfRhfcNpZAW82wSfZWmRqL2qg1va7ZyQNKjq22o7BQS3Ml2lIOxHbktF4uPOxKUsrY13ZrITpMNBjdov_cDbj0xHfm047Ahb9ahvIzOatl6vPr9p9Fq-bRavMTl-_Pr4rGMFeN8iDWFGnSqGasUFJXmmgOHinOmKw6s0gXNaMUw1QowOLKGnIeszPK0zjI2ja6Ptb2z3yP6QTR2dF3YKICz9AAioyH1cEwpZ713WIvehYvdXgAVB6CiEX-BigNQQVlw8zC-PI5jOGRn0AmvDAZI2jhUg9DW_K_oB6lLh9I</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1932187340</pqid></control><display><type>article</type><title>Life cycle climate performance evaluation (LCCP) on cooling and heating systems in South Korea</title><source>Elsevier ScienceDirect Journals</source><creator>Choi, Seyoung ; Oh, Jinwoo ; Hwang, Yunho ; Lee, Hoseong</creator><creatorcontrib>Choi, Seyoung ; Oh, Jinwoo ; Hwang, Yunho ; Lee, Hoseong</creatorcontrib><description>•A new LCCP model is developed and applied to selected Korean cities.•Application of heat pumps can reduce total CO2 emissions up to 9.6% (vs. gas boiler).•Application of heat pumps with R290 reduces total CO2 emissions up to 22.3%.•Vapor injection cycle with R290 can reduce the emission up to 35%.
In this study, a life cycle climate performance (LCCP) of cooling and heating systems is developed and evaluated for South Korean weather conditions. While a heat pump is widely used for both space cooling and heating in United States, the heat pump is only used for space cooling and a gas boiler is used instead for space heating in South Korea. Therefore, LCCP evaluation method is extended with the gas boiler. The evaluation results show that the use of the heat pump for space heating can reduce CO2 emissions by 11–17%. Moreover, various low global warming potential (GWP) refrigerants, cycle options and weather conditions are applied and evaluated. Low GWP refrigerants reduce the direct emissions by decreasing the charging amount compared to R410A. In case of using R290, total CO2 emissions are reduced by 19–22%. The vapor injection cycle with a flash tank with R410A improves energy efficiency and it reduces CO2 emissions by 7–10%. Applying the VI cycle with R32 or R290, the total emissions are reduced by 27–35%.</description><identifier>ISSN: 1359-4311</identifier><identifier>EISSN: 1873-5606</identifier><identifier>DOI: 10.1016/j.applthermaleng.2017.03.105</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Boilers ; Carbon dioxide ; Chilled water systems ; Climate change ; Climatology ; Cooling systems ; Energy management ; Heat pump ; Heating ; Heating systems ; LCCP ; Life cycle assessment ; Life cycle engineering ; Power efficiency ; Pumps ; Refrigerants ; Space cooling (buildings) ; Space heating ; Studies ; Systems analysis ; Vapor injection cycle ; Weather</subject><ispartof>Applied thermal engineering, 2017-06, Vol.120, p.88-98</ispartof><rights>2017 Elsevier Ltd</rights><rights>Copyright Elsevier BV Jun 25, 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c399t-d01f1d2d33bc18bd9d9191b993db913bd8040b3e2dc1e191af1593bca452f443</citedby><cites>FETCH-LOGICAL-c399t-d01f1d2d33bc18bd9d9191b993db913bd8040b3e2dc1e191af1593bca452f443</cites><orcidid>0000-0002-0439-0179</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1359431116334512$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Choi, Seyoung</creatorcontrib><creatorcontrib>Oh, Jinwoo</creatorcontrib><creatorcontrib>Hwang, Yunho</creatorcontrib><creatorcontrib>Lee, Hoseong</creatorcontrib><title>Life cycle climate performance evaluation (LCCP) on cooling and heating systems in South Korea</title><title>Applied thermal engineering</title><description>•A new LCCP model is developed and applied to selected Korean cities.•Application of heat pumps can reduce total CO2 emissions up to 9.6% (vs. gas boiler).•Application of heat pumps with R290 reduces total CO2 emissions up to 22.3%.•Vapor injection cycle with R290 can reduce the emission up to 35%.
In this study, a life cycle climate performance (LCCP) of cooling and heating systems is developed and evaluated for South Korean weather conditions. While a heat pump is widely used for both space cooling and heating in United States, the heat pump is only used for space cooling and a gas boiler is used instead for space heating in South Korea. Therefore, LCCP evaluation method is extended with the gas boiler. The evaluation results show that the use of the heat pump for space heating can reduce CO2 emissions by 11–17%. Moreover, various low global warming potential (GWP) refrigerants, cycle options and weather conditions are applied and evaluated. Low GWP refrigerants reduce the direct emissions by decreasing the charging amount compared to R410A. In case of using R290, total CO2 emissions are reduced by 19–22%. The vapor injection cycle with a flash tank with R410A improves energy efficiency and it reduces CO2 emissions by 7–10%. Applying the VI cycle with R32 or R290, the total emissions are reduced by 27–35%.</description><subject>Boilers</subject><subject>Carbon dioxide</subject><subject>Chilled water systems</subject><subject>Climate change</subject><subject>Climatology</subject><subject>Cooling systems</subject><subject>Energy management</subject><subject>Heat pump</subject><subject>Heating</subject><subject>Heating systems</subject><subject>LCCP</subject><subject>Life cycle assessment</subject><subject>Life cycle engineering</subject><subject>Power efficiency</subject><subject>Pumps</subject><subject>Refrigerants</subject><subject>Space cooling (buildings)</subject><subject>Space heating</subject><subject>Studies</subject><subject>Systems analysis</subject><subject>Vapor injection cycle</subject><subject>Weather</subject><issn>1359-4311</issn><issn>1873-5606</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqNkFFLwzAUhYsoOKf_IaAP-tCa27RbA77IcCoWFNyzIU1ut5SuqUk72L83Y7745kty4Jx7LveLohugCVCY3TeJ7Pt22KDbyha7dZJSmCeUBTc_iSZQzFmcz-jsNGiW8zhjAOfRhfcNpZAW82wSfZWmRqL2qg1va7ZyQNKjq22o7BQS3Ml2lIOxHbktF4uPOxKUsrY13ZrITpMNBjdov_cDbj0xHfm047Ahb9ahvIzOatl6vPr9p9Fq-bRavMTl-_Pr4rGMFeN8iDWFGnSqGasUFJXmmgOHinOmKw6s0gXNaMUw1QowOLKGnIeszPK0zjI2ja6Ptb2z3yP6QTR2dF3YKICz9AAioyH1cEwpZ713WIvehYvdXgAVB6CiEX-BigNQQVlw8zC-PI5jOGRn0AmvDAZI2jhUg9DW_K_oB6lLh9I</recordid><startdate>20170625</startdate><enddate>20170625</enddate><creator>Choi, Seyoung</creator><creator>Oh, Jinwoo</creator><creator>Hwang, Yunho</creator><creator>Lee, Hoseong</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><orcidid>https://orcid.org/0000-0002-0439-0179</orcidid></search><sort><creationdate>20170625</creationdate><title>Life cycle climate performance evaluation (LCCP) on cooling and heating systems in South Korea</title><author>Choi, Seyoung ; Oh, Jinwoo ; Hwang, Yunho ; Lee, Hoseong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c399t-d01f1d2d33bc18bd9d9191b993db913bd8040b3e2dc1e191af1593bca452f443</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Boilers</topic><topic>Carbon dioxide</topic><topic>Chilled water systems</topic><topic>Climate change</topic><topic>Climatology</topic><topic>Cooling systems</topic><topic>Energy management</topic><topic>Heat pump</topic><topic>Heating</topic><topic>Heating systems</topic><topic>LCCP</topic><topic>Life cycle assessment</topic><topic>Life cycle engineering</topic><topic>Power efficiency</topic><topic>Pumps</topic><topic>Refrigerants</topic><topic>Space cooling (buildings)</topic><topic>Space heating</topic><topic>Studies</topic><topic>Systems analysis</topic><topic>Vapor injection cycle</topic><topic>Weather</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Choi, Seyoung</creatorcontrib><creatorcontrib>Oh, Jinwoo</creatorcontrib><creatorcontrib>Hwang, Yunho</creatorcontrib><creatorcontrib>Lee, Hoseong</creatorcontrib><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Applied thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Choi, Seyoung</au><au>Oh, Jinwoo</au><au>Hwang, Yunho</au><au>Lee, Hoseong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Life cycle climate performance evaluation (LCCP) on cooling and heating systems in South Korea</atitle><jtitle>Applied thermal engineering</jtitle><date>2017-06-25</date><risdate>2017</risdate><volume>120</volume><spage>88</spage><epage>98</epage><pages>88-98</pages><issn>1359-4311</issn><eissn>1873-5606</eissn><abstract>•A new LCCP model is developed and applied to selected Korean cities.•Application of heat pumps can reduce total CO2 emissions up to 9.6% (vs. gas boiler).•Application of heat pumps with R290 reduces total CO2 emissions up to 22.3%.•Vapor injection cycle with R290 can reduce the emission up to 35%.
In this study, a life cycle climate performance (LCCP) of cooling and heating systems is developed and evaluated for South Korean weather conditions. While a heat pump is widely used for both space cooling and heating in United States, the heat pump is only used for space cooling and a gas boiler is used instead for space heating in South Korea. Therefore, LCCP evaluation method is extended with the gas boiler. The evaluation results show that the use of the heat pump for space heating can reduce CO2 emissions by 11–17%. Moreover, various low global warming potential (GWP) refrigerants, cycle options and weather conditions are applied and evaluated. Low GWP refrigerants reduce the direct emissions by decreasing the charging amount compared to R410A. In case of using R290, total CO2 emissions are reduced by 19–22%. The vapor injection cycle with a flash tank with R410A improves energy efficiency and it reduces CO2 emissions by 7–10%. Applying the VI cycle with R32 or R290, the total emissions are reduced by 27–35%.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.applthermaleng.2017.03.105</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-0439-0179</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1359-4311 |
ispartof | Applied thermal engineering, 2017-06, Vol.120, p.88-98 |
issn | 1359-4311 1873-5606 |
language | eng |
recordid | cdi_proquest_journals_1932187340 |
source | Elsevier ScienceDirect Journals |
subjects | Boilers Carbon dioxide Chilled water systems Climate change Climatology Cooling systems Energy management Heat pump Heating Heating systems LCCP Life cycle assessment Life cycle engineering Power efficiency Pumps Refrigerants Space cooling (buildings) Space heating Studies Systems analysis Vapor injection cycle Weather |
title | Life cycle climate performance evaluation (LCCP) on cooling and heating systems in South Korea |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T18%3A04%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Life%20cycle%20climate%20performance%20evaluation%20(LCCP)%20on%20cooling%20and%20heating%20systems%20in%20South%20Korea&rft.jtitle=Applied%20thermal%20engineering&rft.au=Choi,%20Seyoung&rft.date=2017-06-25&rft.volume=120&rft.spage=88&rft.epage=98&rft.pages=88-98&rft.issn=1359-4311&rft.eissn=1873-5606&rft_id=info:doi/10.1016/j.applthermaleng.2017.03.105&rft_dat=%3Cproquest_cross%3E1932187340%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1932187340&rft_id=info:pmid/&rft_els_id=S1359431116334512&rfr_iscdi=true |