Effect of Tri-Staple™ Technology and Slow Firing on Secure Stapling Using an Endoscopic Linear Stapler
Aim: To evaluate the effect of Tri-staple™ technology and slow firing using the Endo-GIA™ endoscopic linear stapler. Methods: The cardiac and pyloric portions of porcine stomachs were divided using the endoscopic linear stapler with different reload types. A total of 8 min of waiting time was employ...
Gespeichert in:
Veröffentlicht in: | Digestive surgery 2015-01, Vol.32 (5), p.353-360 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 360 |
---|---|
container_issue | 5 |
container_start_page | 353 |
container_title | Digestive surgery |
container_volume | 32 |
creator | Hasegawa, Suguru Nakayama, Shinya Hida, Koya Kawada, Kenji Sakai, Yoshiharu |
description | Aim: To evaluate the effect of Tri-staple™ technology and slow firing using the Endo-GIA™ endoscopic linear stapler. Methods: The cardiac and pyloric portions of porcine stomachs were divided using the endoscopic linear stapler with different reload types. A total of 8 min of waiting time was employed during firing in the slow-firing group and no waiting time was employed in the normal-firing group. The shape of the staples was then evaluated. The length of the staple line and serosal laceration was also determined. Results: There was a moderate negative correlation between tissue thickness and secure staple formation. Tri-staple™ reloads (purple, black) offered more secure staple formation compared with Universal green reload. Although slow firing enhanced secure staple formation, its effect was greater when using green reload, compared with Tri-staple™ reloads. Significantly shorter staple line length and longer serosal laceration was observed in the thick tissue. Although the cartridge type did not influence lengths of the staple line or serosal laceration, both were better in the slow-firing group. Conclusions: Tri-staple™ reloads offered more secure staple formation compared with the Universal reload. Although slow firing improved staple line shortening and serosal laceration, its effect on secure stapling was relatively small when using Tri-staple™ reloads. |
doi_str_mv | 10.1159/000437216 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_journals_1910321803</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1708164810</sourcerecordid><originalsourceid>FETCH-LOGICAL-c400t-bf452806be23c45d550f84a37292cc132656da9805a5f81b8f878f55b6df4aa23</originalsourceid><addsrcrecordid>eNpd0EFPwyAUB3BiNG5OD96NIfGihypQoPRolk1NlnjYdm4oha2zgwltzO5-Ej-an8TOzh28QAK_9_LeH4BLjO4xZukDQojGCcH8CPQxJThKhYiPQR8RFkdUCN4DZyGsWhbzFJ-CHuGECJImfbAcGaNVDZ2BM19G01puKv39-QVnWi2tq9xiC6Ut4LRyH3Bc-tIuoLNwqlXjNfzlu6d52J3SwpEtXFBuUyo4Ka2WvjPan4MTI6ugL_b3AMzHo9nwOZq8Pr0MHyeRogjVUW4oIwLxXJNYUVYwhoygst0uJUrhmHDGC5kKxCQzAufCiEQYxnJeGColiQfgtuu78e690aHO1mVQuqqk1a4JGU6QwJwKjFp684-uXONtO12G0_afYIHiVt11SnkXgtcm2_hyLf02wyjbxZ8d4m_t9b5jk691cZB_ebfgqgNv0i-0P4B9_Q-8X4ds</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1910321803</pqid></control><display><type>article</type><title>Effect of Tri-Staple™ Technology and Slow Firing on Secure Stapling Using an Endoscopic Linear Stapler</title><source>MEDLINE</source><source>Karger Journals Complete</source><creator>Hasegawa, Suguru ; Nakayama, Shinya ; Hida, Koya ; Kawada, Kenji ; Sakai, Yoshiharu</creator><creatorcontrib>Hasegawa, Suguru ; Nakayama, Shinya ; Hida, Koya ; Kawada, Kenji ; Sakai, Yoshiharu</creatorcontrib><description>Aim: To evaluate the effect of Tri-staple™ technology and slow firing using the Endo-GIA™ endoscopic linear stapler. Methods: The cardiac and pyloric portions of porcine stomachs were divided using the endoscopic linear stapler with different reload types. A total of 8 min of waiting time was employed during firing in the slow-firing group and no waiting time was employed in the normal-firing group. The shape of the staples was then evaluated. The length of the staple line and serosal laceration was also determined. Results: There was a moderate negative correlation between tissue thickness and secure staple formation. Tri-staple™ reloads (purple, black) offered more secure staple formation compared with Universal green reload. Although slow firing enhanced secure staple formation, its effect was greater when using green reload, compared with Tri-staple™ reloads. Significantly shorter staple line length and longer serosal laceration was observed in the thick tissue. Although the cartridge type did not influence lengths of the staple line or serosal laceration, both were better in the slow-firing group. Conclusions: Tri-staple™ reloads offered more secure staple formation compared with the Universal reload. Although slow firing improved staple line shortening and serosal laceration, its effect on secure stapling was relatively small when using Tri-staple™ reloads.</description><identifier>ISSN: 0253-4886</identifier><identifier>EISSN: 1421-9883</identifier><identifier>DOI: 10.1159/000437216</identifier><identifier>PMID: 26228297</identifier><language>eng</language><publisher>Basel, Switzerland: S. Karger AG</publisher><subject>Anastomosis, Surgical ; Animals ; Endoscopy, Gastrointestinal - instrumentation ; Original Paper ; Stomach - surgery ; Surgical Staplers ; Surgical Stapling - instrumentation ; Surgical Stapling - methods ; Swine</subject><ispartof>Digestive surgery, 2015-01, Vol.32 (5), p.353-360</ispartof><rights>2015 S. Karger AG, Basel</rights><rights>2015 S. Karger AG, Basel.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c400t-bf452806be23c45d550f84a37292cc132656da9805a5f81b8f878f55b6df4aa23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,2430,27926,27927</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26228297$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hasegawa, Suguru</creatorcontrib><creatorcontrib>Nakayama, Shinya</creatorcontrib><creatorcontrib>Hida, Koya</creatorcontrib><creatorcontrib>Kawada, Kenji</creatorcontrib><creatorcontrib>Sakai, Yoshiharu</creatorcontrib><title>Effect of Tri-Staple™ Technology and Slow Firing on Secure Stapling Using an Endoscopic Linear Stapler</title><title>Digestive surgery</title><addtitle>Dig Surg</addtitle><description>Aim: To evaluate the effect of Tri-staple™ technology and slow firing using the Endo-GIA™ endoscopic linear stapler. Methods: The cardiac and pyloric portions of porcine stomachs were divided using the endoscopic linear stapler with different reload types. A total of 8 min of waiting time was employed during firing in the slow-firing group and no waiting time was employed in the normal-firing group. The shape of the staples was then evaluated. The length of the staple line and serosal laceration was also determined. Results: There was a moderate negative correlation between tissue thickness and secure staple formation. Tri-staple™ reloads (purple, black) offered more secure staple formation compared with Universal green reload. Although slow firing enhanced secure staple formation, its effect was greater when using green reload, compared with Tri-staple™ reloads. Significantly shorter staple line length and longer serosal laceration was observed in the thick tissue. Although the cartridge type did not influence lengths of the staple line or serosal laceration, both were better in the slow-firing group. Conclusions: Tri-staple™ reloads offered more secure staple formation compared with the Universal reload. Although slow firing improved staple line shortening and serosal laceration, its effect on secure stapling was relatively small when using Tri-staple™ reloads.</description><subject>Anastomosis, Surgical</subject><subject>Animals</subject><subject>Endoscopy, Gastrointestinal - instrumentation</subject><subject>Original Paper</subject><subject>Stomach - surgery</subject><subject>Surgical Staplers</subject><subject>Surgical Stapling - instrumentation</subject><subject>Surgical Stapling - methods</subject><subject>Swine</subject><issn>0253-4886</issn><issn>1421-9883</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNpd0EFPwyAUB3BiNG5OD96NIfGihypQoPRolk1NlnjYdm4oha2zgwltzO5-Ej-an8TOzh28QAK_9_LeH4BLjO4xZukDQojGCcH8CPQxJThKhYiPQR8RFkdUCN4DZyGsWhbzFJ-CHuGECJImfbAcGaNVDZ2BM19G01puKv39-QVnWi2tq9xiC6Ut4LRyH3Bc-tIuoLNwqlXjNfzlu6d52J3SwpEtXFBuUyo4Ka2WvjPan4MTI6ugL_b3AMzHo9nwOZq8Pr0MHyeRogjVUW4oIwLxXJNYUVYwhoygst0uJUrhmHDGC5kKxCQzAufCiEQYxnJeGColiQfgtuu78e690aHO1mVQuqqk1a4JGU6QwJwKjFp684-uXONtO12G0_afYIHiVt11SnkXgtcm2_hyLf02wyjbxZ8d4m_t9b5jk691cZB_ebfgqgNv0i-0P4B9_Q-8X4ds</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Hasegawa, Suguru</creator><creator>Nakayama, Shinya</creator><creator>Hida, Koya</creator><creator>Kawada, Kenji</creator><creator>Sakai, Yoshiharu</creator><general>S. Karger AG</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QO</scope><scope>7QP</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20150101</creationdate><title>Effect of Tri-Staple™ Technology and Slow Firing on Secure Stapling Using an Endoscopic Linear Stapler</title><author>Hasegawa, Suguru ; Nakayama, Shinya ; Hida, Koya ; Kawada, Kenji ; Sakai, Yoshiharu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c400t-bf452806be23c45d550f84a37292cc132656da9805a5f81b8f878f55b6df4aa23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Anastomosis, Surgical</topic><topic>Animals</topic><topic>Endoscopy, Gastrointestinal - instrumentation</topic><topic>Original Paper</topic><topic>Stomach - surgery</topic><topic>Surgical Staplers</topic><topic>Surgical Stapling - instrumentation</topic><topic>Surgical Stapling - methods</topic><topic>Swine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hasegawa, Suguru</creatorcontrib><creatorcontrib>Nakayama, Shinya</creatorcontrib><creatorcontrib>Hida, Koya</creatorcontrib><creatorcontrib>Kawada, Kenji</creatorcontrib><creatorcontrib>Sakai, Yoshiharu</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Biotechnology Research Abstracts</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Digestive surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hasegawa, Suguru</au><au>Nakayama, Shinya</au><au>Hida, Koya</au><au>Kawada, Kenji</au><au>Sakai, Yoshiharu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Tri-Staple™ Technology and Slow Firing on Secure Stapling Using an Endoscopic Linear Stapler</atitle><jtitle>Digestive surgery</jtitle><addtitle>Dig Surg</addtitle><date>2015-01-01</date><risdate>2015</risdate><volume>32</volume><issue>5</issue><spage>353</spage><epage>360</epage><pages>353-360</pages><issn>0253-4886</issn><eissn>1421-9883</eissn><abstract>Aim: To evaluate the effect of Tri-staple™ technology and slow firing using the Endo-GIA™ endoscopic linear stapler. Methods: The cardiac and pyloric portions of porcine stomachs were divided using the endoscopic linear stapler with different reload types. A total of 8 min of waiting time was employed during firing in the slow-firing group and no waiting time was employed in the normal-firing group. The shape of the staples was then evaluated. The length of the staple line and serosal laceration was also determined. Results: There was a moderate negative correlation between tissue thickness and secure staple formation. Tri-staple™ reloads (purple, black) offered more secure staple formation compared with Universal green reload. Although slow firing enhanced secure staple formation, its effect was greater when using green reload, compared with Tri-staple™ reloads. Significantly shorter staple line length and longer serosal laceration was observed in the thick tissue. Although the cartridge type did not influence lengths of the staple line or serosal laceration, both were better in the slow-firing group. Conclusions: Tri-staple™ reloads offered more secure staple formation compared with the Universal reload. Although slow firing improved staple line shortening and serosal laceration, its effect on secure stapling was relatively small when using Tri-staple™ reloads.</abstract><cop>Basel, Switzerland</cop><pub>S. Karger AG</pub><pmid>26228297</pmid><doi>10.1159/000437216</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0253-4886 |
ispartof | Digestive surgery, 2015-01, Vol.32 (5), p.353-360 |
issn | 0253-4886 1421-9883 |
language | eng |
recordid | cdi_proquest_journals_1910321803 |
source | MEDLINE; Karger Journals Complete |
subjects | Anastomosis, Surgical Animals Endoscopy, Gastrointestinal - instrumentation Original Paper Stomach - surgery Surgical Staplers Surgical Stapling - instrumentation Surgical Stapling - methods Swine |
title | Effect of Tri-Staple™ Technology and Slow Firing on Secure Stapling Using an Endoscopic Linear Stapler |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T00%3A05%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Tri-Staple%E2%84%A2%20Technology%20and%20Slow%20Firing%20on%20Secure%20Stapling%20Using%20an%20Endoscopic%20Linear%20Stapler&rft.jtitle=Digestive%20surgery&rft.au=Hasegawa,%20Suguru&rft.date=2015-01-01&rft.volume=32&rft.issue=5&rft.spage=353&rft.epage=360&rft.pages=353-360&rft.issn=0253-4886&rft.eissn=1421-9883&rft_id=info:doi/10.1159/000437216&rft_dat=%3Cproquest_pubme%3E1708164810%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1910321803&rft_id=info:pmid/26228297&rfr_iscdi=true |