対向配置した高温超伝導バルク磁石を用いた均一な磁場空間を生成する新たな試み
Various experimental attempts have been made to obtain a uniform magnetic field in the space between face-to-face HTS bulk magnets that could possibly be utilized as NMR magnets. In general, the magnetic fields emitted from the magnetic pole surfaces containing HTS bulk magnets are characterized as...
Gespeichert in:
Veröffentlicht in: | Teion kōgaku 2017/01/20, Vol.52(1), pp.38-43 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 43 |
---|---|
container_issue | 1 |
container_start_page | 38 |
container_title | Teion kōgaku |
container_volume | 52 |
creator | 岡, 徹雄 一重, 佳那 比嘉, 和也 福井, 聡 小川, 純 佐藤, 孝雄 横山, 和哉 仲村, 髙志 |
description | Various experimental attempts have been made to obtain a uniform magnetic field in the space between face-to-face HTS bulk magnets that could possibly be utilized as NMR magnets. In general, the magnetic fields emitted from the magnetic pole surfaces containing HTS bulk magnets are characterized as non-uniform field distributions. Since the NMR magnets require highly uniform magnetic-field spaces, it has been assumed to be difficult to form uniform magnetic-field spaces between magnetic poles placed face-to-face. The authors modified the shapes of the magnetic-field distribution from convex to concave by attaching ferromagnetic iron plates to the pole surfaces. The magnets were then set face-to-face with various gaps of 30-70 mm, and the experimental data on magnetic-field uniformity was precisely measured in the space. In order to detect the NMR signals, the target performance for uniformity was set as 1,500 ppm throughout the 4-mm span on the x-axis, which is equivalent to performance in the past when the world's first detection of NMR signals was observed in the bore of hollow-type HTS bulk magnets. When we combined the concave and convex field distributions to compensate the uneven field distributions, the data of the best uniformity reached 358 ppm and 493 ppm in the 30 mm and 50 mm gaps, respectively, which exceeded the target value for the purpose of detecting the NMR signals within the space. Furthermore, it was shown that the field distributions change from concave to convex shape without any change at 1.1 T in the range from 7 to 11 mm in the 30-mm gap, indicating that the distributions are uniform. This suggests the possibility that the uniform magnetic-field space between the HTS bulk magnets set face-to-face expands. |
doi_str_mv | 10.2221/jcsj.52.38 |
format | Article |
fullrecord | <record><control><sourceid>proquest_jstag</sourceid><recordid>TN_cdi_proquest_journals_1874495602</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1874495602</sourcerecordid><originalsourceid>FETCH-LOGICAL-j2762-2e1c5a1c853c018214374bc3567cb799143f60fa7cb0f0a4f0839a7232ff606c3</originalsourceid><addsrcrecordid>eNo9kEtLAlEYhg9RkJSb_kLrsXOZy5lFi5BuILSp9XA8zJSDpc3Yol2jSUEUdsFqIQZBZEIKRUh0-THHcfRfdMxo87287_fwvfABMINgAmOM5lzuuwkNJwgdAzFEKVSgCuk4iEFCTQWrKpoEcd_PpCGEpo40HcdALmx9hZXzQfk0-nwWwbUI6oPmTa_T6L-Vux-1sH0mShVRaopiK7oPovqLKF5EV48iOJRkWDvqdg5E8CRX4d1r1HgfVC9_gXrvuCKCW1E86VXbkpRMv_Eggu9pMOGwrG_H_3QKbCwtridXlNTa8mpyIaW42NCxgm3ENYY41QiHiGKkEkNNc6LpBk8bpim9o0OHSQcdyFQHUmIyAxPsyFznZArMju7mvdzunu0XLDe35-3ISgtRQ1VNTYdYUvMjyvULbNO28l5mm3n7FvMKGZ61reFHLQ1baDgI_c_5FvMsl5Efnq6Wpw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1874495602</pqid></control><display><type>article</type><title>対向配置した高温超伝導バルク磁石を用いた均一な磁場空間を生成する新たな試み</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese</source><creator>岡, 徹雄 ; 一重, 佳那 ; 比嘉, 和也 ; 福井, 聡 ; 小川, 純 ; 佐藤, 孝雄 ; 横山, 和哉 ; 仲村, 髙志</creator><creatorcontrib>岡, 徹雄 ; 一重, 佳那 ; 比嘉, 和也 ; 福井, 聡 ; 小川, 純 ; 佐藤, 孝雄 ; 横山, 和哉 ; 仲村, 髙志</creatorcontrib><description>Various experimental attempts have been made to obtain a uniform magnetic field in the space between face-to-face HTS bulk magnets that could possibly be utilized as NMR magnets. In general, the magnetic fields emitted from the magnetic pole surfaces containing HTS bulk magnets are characterized as non-uniform field distributions. Since the NMR magnets require highly uniform magnetic-field spaces, it has been assumed to be difficult to form uniform magnetic-field spaces between magnetic poles placed face-to-face. The authors modified the shapes of the magnetic-field distribution from convex to concave by attaching ferromagnetic iron plates to the pole surfaces. The magnets were then set face-to-face with various gaps of 30-70 mm, and the experimental data on magnetic-field uniformity was precisely measured in the space. In order to detect the NMR signals, the target performance for uniformity was set as 1,500 ppm throughout the 4-mm span on the x-axis, which is equivalent to performance in the past when the world's first detection of NMR signals was observed in the bore of hollow-type HTS bulk magnets. When we combined the concave and convex field distributions to compensate the uneven field distributions, the data of the best uniformity reached 358 ppm and 493 ppm in the 30 mm and 50 mm gaps, respectively, which exceeded the target value for the purpose of detecting the NMR signals within the space. Furthermore, it was shown that the field distributions change from concave to convex shape without any change at 1.1 T in the range from 7 to 11 mm in the 30-mm gap, indicating that the distributions are uniform. This suggests the possibility that the uniform magnetic-field space between the HTS bulk magnets set face-to-face expands.</description><identifier>ISSN: 0389-2441</identifier><identifier>EISSN: 1880-0408</identifier><identifier>DOI: 10.2221/jcsj.52.38</identifier><language>jpn</language><publisher>Tokyo: 公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)</publisher><subject>Ferromagnetism ; Magnetic fields ; Magnetic poles ; Magnets ; NMR ; Nuclear magnetic resonance ; Target detection</subject><ispartof>低温工学, 2017/01/20, Vol.52(1), pp.38-43</ispartof><rights>2017 公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)</rights><rights>Copyright Japan Science and Technology Agency 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1882,27923,27924</link.rule.ids></links><search><creatorcontrib>岡, 徹雄</creatorcontrib><creatorcontrib>一重, 佳那</creatorcontrib><creatorcontrib>比嘉, 和也</creatorcontrib><creatorcontrib>福井, 聡</creatorcontrib><creatorcontrib>小川, 純</creatorcontrib><creatorcontrib>佐藤, 孝雄</creatorcontrib><creatorcontrib>横山, 和哉</creatorcontrib><creatorcontrib>仲村, 髙志</creatorcontrib><title>対向配置した高温超伝導バルク磁石を用いた均一な磁場空間を生成する新たな試み</title><title>Teion kōgaku</title><addtitle>低温工学</addtitle><description>Various experimental attempts have been made to obtain a uniform magnetic field in the space between face-to-face HTS bulk magnets that could possibly be utilized as NMR magnets. In general, the magnetic fields emitted from the magnetic pole surfaces containing HTS bulk magnets are characterized as non-uniform field distributions. Since the NMR magnets require highly uniform magnetic-field spaces, it has been assumed to be difficult to form uniform magnetic-field spaces between magnetic poles placed face-to-face. The authors modified the shapes of the magnetic-field distribution from convex to concave by attaching ferromagnetic iron plates to the pole surfaces. The magnets were then set face-to-face with various gaps of 30-70 mm, and the experimental data on magnetic-field uniformity was precisely measured in the space. In order to detect the NMR signals, the target performance for uniformity was set as 1,500 ppm throughout the 4-mm span on the x-axis, which is equivalent to performance in the past when the world's first detection of NMR signals was observed in the bore of hollow-type HTS bulk magnets. When we combined the concave and convex field distributions to compensate the uneven field distributions, the data of the best uniformity reached 358 ppm and 493 ppm in the 30 mm and 50 mm gaps, respectively, which exceeded the target value for the purpose of detecting the NMR signals within the space. Furthermore, it was shown that the field distributions change from concave to convex shape without any change at 1.1 T in the range from 7 to 11 mm in the 30-mm gap, indicating that the distributions are uniform. This suggests the possibility that the uniform magnetic-field space between the HTS bulk magnets set face-to-face expands.</description><subject>Ferromagnetism</subject><subject>Magnetic fields</subject><subject>Magnetic poles</subject><subject>Magnets</subject><subject>NMR</subject><subject>Nuclear magnetic resonance</subject><subject>Target detection</subject><issn>0389-2441</issn><issn>1880-0408</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNo9kEtLAlEYhg9RkJSb_kLrsXOZy5lFi5BuILSp9XA8zJSDpc3Yol2jSUEUdsFqIQZBZEIKRUh0-THHcfRfdMxo87287_fwvfABMINgAmOM5lzuuwkNJwgdAzFEKVSgCuk4iEFCTQWrKpoEcd_PpCGEpo40HcdALmx9hZXzQfk0-nwWwbUI6oPmTa_T6L-Vux-1sH0mShVRaopiK7oPovqLKF5EV48iOJRkWDvqdg5E8CRX4d1r1HgfVC9_gXrvuCKCW1E86VXbkpRMv_Eggu9pMOGwrG_H_3QKbCwtridXlNTa8mpyIaW42NCxgm3ENYY41QiHiGKkEkNNc6LpBk8bpim9o0OHSQcdyFQHUmIyAxPsyFznZArMju7mvdzunu0XLDe35-3ISgtRQ1VNTYdYUvMjyvULbNO28l5mm3n7FvMKGZ61reFHLQ1baDgI_c_5FvMsl5Efnq6Wpw</recordid><startdate>20170101</startdate><enddate>20170101</enddate><creator>岡, 徹雄</creator><creator>一重, 佳那</creator><creator>比嘉, 和也</creator><creator>福井, 聡</creator><creator>小川, 純</creator><creator>佐藤, 孝雄</creator><creator>横山, 和哉</creator><creator>仲村, 髙志</creator><general>公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)</general><general>Japan Science and Technology Agency</general><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20170101</creationdate><title>対向配置した高温超伝導バルク磁石を用いた均一な磁場空間を生成する新たな試み</title><author>岡, 徹雄 ; 一重, 佳那 ; 比嘉, 和也 ; 福井, 聡 ; 小川, 純 ; 佐藤, 孝雄 ; 横山, 和哉 ; 仲村, 髙志</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j2762-2e1c5a1c853c018214374bc3567cb799143f60fa7cb0f0a4f0839a7232ff606c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>2017</creationdate><topic>Ferromagnetism</topic><topic>Magnetic fields</topic><topic>Magnetic poles</topic><topic>Magnets</topic><topic>NMR</topic><topic>Nuclear magnetic resonance</topic><topic>Target detection</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>岡, 徹雄</creatorcontrib><creatorcontrib>一重, 佳那</creatorcontrib><creatorcontrib>比嘉, 和也</creatorcontrib><creatorcontrib>福井, 聡</creatorcontrib><creatorcontrib>小川, 純</creatorcontrib><creatorcontrib>佐藤, 孝雄</creatorcontrib><creatorcontrib>横山, 和哉</creatorcontrib><creatorcontrib>仲村, 髙志</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Teion kōgaku</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>岡, 徹雄</au><au>一重, 佳那</au><au>比嘉, 和也</au><au>福井, 聡</au><au>小川, 純</au><au>佐藤, 孝雄</au><au>横山, 和哉</au><au>仲村, 髙志</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>対向配置した高温超伝導バルク磁石を用いた均一な磁場空間を生成する新たな試み</atitle><jtitle>Teion kōgaku</jtitle><addtitle>低温工学</addtitle><date>2017-01-01</date><risdate>2017</risdate><volume>52</volume><issue>1</issue><spage>38</spage><epage>43</epage><pages>38-43</pages><issn>0389-2441</issn><eissn>1880-0408</eissn><abstract>Various experimental attempts have been made to obtain a uniform magnetic field in the space between face-to-face HTS bulk magnets that could possibly be utilized as NMR magnets. In general, the magnetic fields emitted from the magnetic pole surfaces containing HTS bulk magnets are characterized as non-uniform field distributions. Since the NMR magnets require highly uniform magnetic-field spaces, it has been assumed to be difficult to form uniform magnetic-field spaces between magnetic poles placed face-to-face. The authors modified the shapes of the magnetic-field distribution from convex to concave by attaching ferromagnetic iron plates to the pole surfaces. The magnets were then set face-to-face with various gaps of 30-70 mm, and the experimental data on magnetic-field uniformity was precisely measured in the space. In order to detect the NMR signals, the target performance for uniformity was set as 1,500 ppm throughout the 4-mm span on the x-axis, which is equivalent to performance in the past when the world's first detection of NMR signals was observed in the bore of hollow-type HTS bulk magnets. When we combined the concave and convex field distributions to compensate the uneven field distributions, the data of the best uniformity reached 358 ppm and 493 ppm in the 30 mm and 50 mm gaps, respectively, which exceeded the target value for the purpose of detecting the NMR signals within the space. Furthermore, it was shown that the field distributions change from concave to convex shape without any change at 1.1 T in the range from 7 to 11 mm in the 30-mm gap, indicating that the distributions are uniform. This suggests the possibility that the uniform magnetic-field space between the HTS bulk magnets set face-to-face expands.</abstract><cop>Tokyo</cop><pub>公益社団法人 低温工学・超電導学会 (旧 社団法人 低温工学協会)</pub><doi>10.2221/jcsj.52.38</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0389-2441 |
ispartof | 低温工学, 2017/01/20, Vol.52(1), pp.38-43 |
issn | 0389-2441 1880-0408 |
language | jpn |
recordid | cdi_proquest_journals_1874495602 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese |
subjects | Ferromagnetism Magnetic fields Magnetic poles Magnets NMR Nuclear magnetic resonance Target detection |
title | 対向配置した高温超伝導バルク磁石を用いた均一な磁場空間を生成する新たな試み |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T17%3A45%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_jstag&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=%E5%AF%BE%E5%90%91%E9%85%8D%E7%BD%AE%E3%81%97%E3%81%9F%E9%AB%98%E6%B8%A9%E8%B6%85%E4%BC%9D%E5%B0%8E%E3%83%90%E3%83%AB%E3%82%AF%E7%A3%81%E7%9F%B3%E3%82%92%E7%94%A8%E3%81%84%E3%81%9F%E5%9D%87%E4%B8%80%E3%81%AA%E7%A3%81%E5%A0%B4%E7%A9%BA%E9%96%93%E3%82%92%E7%94%9F%E6%88%90%E3%81%99%E3%82%8B%E6%96%B0%E3%81%9F%E3%81%AA%E8%A9%A6%E3%81%BF&rft.jtitle=Teion%20k%C5%8Dgaku&rft.au=%E5%B2%A1,%20%E5%BE%B9%E9%9B%84&rft.date=2017-01-01&rft.volume=52&rft.issue=1&rft.spage=38&rft.epage=43&rft.pages=38-43&rft.issn=0389-2441&rft.eissn=1880-0408&rft_id=info:doi/10.2221/jcsj.52.38&rft_dat=%3Cproquest_jstag%3E1874495602%3C/proquest_jstag%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1874495602&rft_id=info:pmid/&rfr_iscdi=true |