Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior
In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthqua...
Gespeichert in:
Veröffentlicht in: | Advanced Engineering Forum 2017-03, Vol.21, p.45-49 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 49 |
---|---|
container_issue | |
container_start_page | 45 |
container_title | Advanced Engineering Forum |
container_volume | 21 |
creator | Unal, Alptug Kamanli, Mehmet |
description | In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world. In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior. For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program. As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined. The graphs and the data were compared and the results were discussed. |
doi_str_mv | 10.4028/www.scientific.net/AEF.21.45 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1873863584</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>4318344281</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1955-781cf5e92a9decddc76b718409d73342e90ba0ceee2c85b25f740d8f5966efd83</originalsourceid><addsrcrecordid>eNqNkFtLAzEQhYMXUGv_Q0Bfu81ls5uACLW0tlBQRNG3sM1O2kjN1mTb4r83UkUffZoZZs45zIfQJSVZTpjs73a7LBoHvnXWmcxD2x-MxhmjWS4O0CljPO8pRV8O0RknXJSUKCmPfhZSyRPUjfGVEMIolbwgp-h56rcQW7eoWtd43Fh8v6rSbPDE-QXgGfhFu8TO4wdw3jbBQI2HjTcBWkjNavPmI07KfYtvYFltXRPO0bGtVhG637WDnsajx-GkN7u7nQ4Hs56hSoheKamxAhSrVA2mrk1ZzEsqc6LqkvOcgSLzihgAYEaKORO2zEktrVBFAbaWvIMu9r7r0Lxv0if6tdkEnyI1lSWXBRcyT1dX-ysTmhgDWL0O7q0KH5oS_YVWJ7T6F61OaHVCqxnVuUjy6728DZWPLZjln5T_GHwCEQCIUA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1873863584</pqid></control><display><type>article</type><title>Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior</title><source>Scientific.net Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Unal, Alptug ; Kamanli, Mehmet</creator><creatorcontrib>Unal, Alptug ; Kamanli, Mehmet</creatorcontrib><description>In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world. In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior. For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program. As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined. The graphs and the data were compared and the results were discussed.</description><identifier>ISSN: 2234-9898</identifier><identifier>ISSN: 2234-991X</identifier><identifier>ISBN: 3035710988</identifier><identifier>ISBN: 9783035710984</identifier><identifier>EISSN: 2234-991X</identifier><identifier>DOI: 10.4028/www.scientific.net/AEF.21.45</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><ispartof>Advanced Engineering Forum, 2017-03, Vol.21, p.45-49</ispartof><rights>2017 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Mar 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1955-781cf5e92a9decddc76b718409d73342e90ba0ceee2c85b25f740d8f5966efd83</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/4448?width=600</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Unal, Alptug</creatorcontrib><creatorcontrib>Kamanli, Mehmet</creatorcontrib><title>Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior</title><title>Advanced Engineering Forum</title><description>In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world. In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior. For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program. As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined. The graphs and the data were compared and the results were discussed.</description><issn>2234-9898</issn><issn>2234-991X</issn><issn>2234-991X</issn><isbn>3035710988</isbn><isbn>9783035710984</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNkFtLAzEQhYMXUGv_Q0Bfu81ls5uACLW0tlBQRNG3sM1O2kjN1mTb4r83UkUffZoZZs45zIfQJSVZTpjs73a7LBoHvnXWmcxD2x-MxhmjWS4O0CljPO8pRV8O0RknXJSUKCmPfhZSyRPUjfGVEMIolbwgp-h56rcQW7eoWtd43Fh8v6rSbPDE-QXgGfhFu8TO4wdw3jbBQI2HjTcBWkjNavPmI07KfYtvYFltXRPO0bGtVhG637WDnsajx-GkN7u7nQ4Hs56hSoheKamxAhSrVA2mrk1ZzEsqc6LqkvOcgSLzihgAYEaKORO2zEktrVBFAbaWvIMu9r7r0Lxv0if6tdkEnyI1lSWXBRcyT1dX-ysTmhgDWL0O7q0KH5oS_YVWJ7T6F61OaHVCqxnVuUjy6728DZWPLZjln5T_GHwCEQCIUA</recordid><startdate>20170301</startdate><enddate>20170301</enddate><creator>Unal, Alptug</creator><creator>Kamanli, Mehmet</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20170301</creationdate><title>Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior</title><author>Unal, Alptug ; Kamanli, Mehmet</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1955-781cf5e92a9decddc76b718409d73342e90ba0ceee2c85b25f740d8f5966efd83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Unal, Alptug</creatorcontrib><creatorcontrib>Kamanli, Mehmet</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Advanced Engineering Forum</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Unal, Alptug</au><au>Kamanli, Mehmet</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior</atitle><jtitle>Advanced Engineering Forum</jtitle><date>2017-03-01</date><risdate>2017</risdate><volume>21</volume><spage>45</spage><epage>49</epage><pages>45-49</pages><issn>2234-9898</issn><issn>2234-991X</issn><eissn>2234-991X</eissn><isbn>3035710988</isbn><isbn>9783035710984</isbn><abstract>In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world. In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior. For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program. As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined. The graphs and the data were compared and the results were discussed.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AEF.21.45</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2234-9898 |
ispartof | Advanced Engineering Forum, 2017-03, Vol.21, p.45-49 |
issn | 2234-9898 2234-991X 2234-991X |
language | eng |
recordid | cdi_proquest_journals_1873863584 |
source | Scientific.net Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
title | Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T01%3A37%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Investigation%20of%20Plastic%20Hinge%20Length%20in%20Reinforced%20Concrete%20Columns%20on%20Column%20Behavior&rft.jtitle=Advanced%20Engineering%20Forum&rft.au=Unal,%20Alptug&rft.date=2017-03-01&rft.volume=21&rft.spage=45&rft.epage=49&rft.pages=45-49&rft.issn=2234-9898&rft.eissn=2234-991X&rft.isbn=3035710988&rft.isbn_list=9783035710984&rft_id=info:doi/10.4028/www.scientific.net/AEF.21.45&rft_dat=%3Cproquest_cross%3E4318344281%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1873863584&rft_id=info:pmid/&rfr_iscdi=true |