Longitudinal analysis of bone metabolism using SPECT/CT and ^sup 99m^Tc-diphosphono-propanedicarboxylic acid: comparison of visual and quantitative analysis

Background The therapy response of osseous metastases (OM) is commonly monitored by bone scintigraphies (BS). The aim of this study was to compare visual evaluation of changes in tracer uptake with quantitation in absolute units in OMs; 52 OMs from 19 patients who underwent BS with SPECT/CT at time...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:EJNMMI research 2016-07, Vol.6 (1), p.1
Hauptverfasser: Beck, Michael, Sanders, James C, Ritt, Philipp, Reinfelder, Julia, Kuwert, Torsten
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 1
container_title EJNMMI research
container_volume 6
creator Beck, Michael
Sanders, James C
Ritt, Philipp
Reinfelder, Julia
Kuwert, Torsten
description Background The therapy response of osseous metastases (OM) is commonly monitored by bone scintigraphies (BS). The aim of this study was to compare visual evaluation of changes in tracer uptake with quantitation in absolute units in OMs; 52 OMs from 19 patients who underwent BS with SPECT/CT at time points one and two (TP1/2) were analyzed retrospectively, with an average of 10.3 months between TP1 and 2. Tracer uptake in lesions was visually compared by two independent readers in both planar scintigraphies and SPECT/CT across both TPs and classified as regressive, stable, or progressive. Quantitative analysis was performed by measuring peak standardized uptake values (SUV). Based on quantitation, lesions were similarly classified as regressive (>30 % decrease), progressive (>30 % increase), or stable (rest). If available, uptake in reference regions in the lower thoracic or lumbar spine was used for normalization. Results In OMs at TP1 and TP2, mean SUVpeak (±SD) was found to be 20.4 (±20.8) and 16.4 (±11.5), respectively. For the reference region, mean SUVmean was 5.6 (±1.9) and 4.9 (±2.2). Agreement between quantitative and visual assessment was only moderate, with an average Cohen's kappa of 0.42 for planar scintigraphy and 0.62 for SPECT/CT. Discrepancies occurred in between 11 and 22 of the 52 lesions, depending on the reader and whether planar or SPECT imaging was considered. Conclusions Compared to measuring uptake in absolute units, visual evaluation of skeletal scintigraphies for change in tumor metabolism yields inconsistent results in roughly one third of the cases.
doi_str_mv 10.1186/s13550-016-0217-4
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_1865223099</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>4312248411</sourcerecordid><originalsourceid>FETCH-proquest_journals_18652230993</originalsourceid><addsrcrecordid>eNqNj8FKAzEQhoMgWLQP4C3gOTbZdWvjdal48CB0D55asklap-xmtjtJse_iw5qKeHZg_v_ywTfD2K2S90ot5jNSZVVJIdVcyEI9iocLNimUViLH-xWbEu1lnkpVulxM2Ncrhh3E5CCYjpscJwLiuOUtBs97H02LHVDPE0HY8dXbsm5mdZNRx9eUBq51v26scDB8IOUNKIYRBxO8A2vGFj9PHVhuLLgnbrEfzAiE4aw4AqUfq-OHZEKEaCIc_d8ZN-xyazry09--ZnfPy6Z-OQsOyVPc7DGNGaZNfr0qilJqXf6P-gatbGEw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1865223099</pqid></control><display><type>article</type><title>Longitudinal analysis of bone metabolism using SPECT/CT and ^sup 99m^Tc-diphosphono-propanedicarboxylic acid: comparison of visual and quantitative analysis</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>Springer Nature OA Free Journals</source><source>Springer Nature - Complete Springer Journals</source><source>PubMed Central</source><creator>Beck, Michael ; Sanders, James C ; Ritt, Philipp ; Reinfelder, Julia ; Kuwert, Torsten</creator><creatorcontrib>Beck, Michael ; Sanders, James C ; Ritt, Philipp ; Reinfelder, Julia ; Kuwert, Torsten</creatorcontrib><description>Background The therapy response of osseous metastases (OM) is commonly monitored by bone scintigraphies (BS). The aim of this study was to compare visual evaluation of changes in tracer uptake with quantitation in absolute units in OMs; 52 OMs from 19 patients who underwent BS with SPECT/CT at time points one and two (TP1/2) were analyzed retrospectively, with an average of 10.3 months between TP1 and 2. Tracer uptake in lesions was visually compared by two independent readers in both planar scintigraphies and SPECT/CT across both TPs and classified as regressive, stable, or progressive. Quantitative analysis was performed by measuring peak standardized uptake values (SUV). Based on quantitation, lesions were similarly classified as regressive (&gt;30 % decrease), progressive (&gt;30 % increase), or stable (rest). If available, uptake in reference regions in the lower thoracic or lumbar spine was used for normalization. Results In OMs at TP1 and TP2, mean SUVpeak (±SD) was found to be 20.4 (±20.8) and 16.4 (±11.5), respectively. For the reference region, mean SUVmean was 5.6 (±1.9) and 4.9 (±2.2). Agreement between quantitative and visual assessment was only moderate, with an average Cohen's kappa of 0.42 for planar scintigraphy and 0.62 for SPECT/CT. Discrepancies occurred in between 11 and 22 of the 52 lesions, depending on the reader and whether planar or SPECT imaging was considered. Conclusions Compared to measuring uptake in absolute units, visual evaluation of skeletal scintigraphies for change in tumor metabolism yields inconsistent results in roughly one third of the cases.</description><identifier>EISSN: 2191-219X</identifier><identifier>DOI: 10.1186/s13550-016-0217-4</identifier><language>eng</language><publisher>Heidelberg: Springer Nature B.V</publisher><ispartof>EJNMMI research, 2016-07, Vol.6 (1), p.1</ispartof><rights>EJNMMI Research is a copyright of Springer, 2016.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,861,27905,27906</link.rule.ids></links><search><creatorcontrib>Beck, Michael</creatorcontrib><creatorcontrib>Sanders, James C</creatorcontrib><creatorcontrib>Ritt, Philipp</creatorcontrib><creatorcontrib>Reinfelder, Julia</creatorcontrib><creatorcontrib>Kuwert, Torsten</creatorcontrib><title>Longitudinal analysis of bone metabolism using SPECT/CT and ^sup 99m^Tc-diphosphono-propanedicarboxylic acid: comparison of visual and quantitative analysis</title><title>EJNMMI research</title><description>Background The therapy response of osseous metastases (OM) is commonly monitored by bone scintigraphies (BS). The aim of this study was to compare visual evaluation of changes in tracer uptake with quantitation in absolute units in OMs; 52 OMs from 19 patients who underwent BS with SPECT/CT at time points one and two (TP1/2) were analyzed retrospectively, with an average of 10.3 months between TP1 and 2. Tracer uptake in lesions was visually compared by two independent readers in both planar scintigraphies and SPECT/CT across both TPs and classified as regressive, stable, or progressive. Quantitative analysis was performed by measuring peak standardized uptake values (SUV). Based on quantitation, lesions were similarly classified as regressive (&gt;30 % decrease), progressive (&gt;30 % increase), or stable (rest). If available, uptake in reference regions in the lower thoracic or lumbar spine was used for normalization. Results In OMs at TP1 and TP2, mean SUVpeak (±SD) was found to be 20.4 (±20.8) and 16.4 (±11.5), respectively. For the reference region, mean SUVmean was 5.6 (±1.9) and 4.9 (±2.2). Agreement between quantitative and visual assessment was only moderate, with an average Cohen's kappa of 0.42 for planar scintigraphy and 0.62 for SPECT/CT. Discrepancies occurred in between 11 and 22 of the 52 lesions, depending on the reader and whether planar or SPECT imaging was considered. Conclusions Compared to measuring uptake in absolute units, visual evaluation of skeletal scintigraphies for change in tumor metabolism yields inconsistent results in roughly one third of the cases.</description><issn>2191-219X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNj8FKAzEQhoMgWLQP4C3gOTbZdWvjdal48CB0D55asklap-xmtjtJse_iw5qKeHZg_v_ywTfD2K2S90ot5jNSZVVJIdVcyEI9iocLNimUViLH-xWbEu1lnkpVulxM2Ncrhh3E5CCYjpscJwLiuOUtBs97H02LHVDPE0HY8dXbsm5mdZNRx9eUBq51v26scDB8IOUNKIYRBxO8A2vGFj9PHVhuLLgnbrEfzAiE4aw4AqUfq-OHZEKEaCIc_d8ZN-xyazry09--ZnfPy6Z-OQsOyVPc7DGNGaZNfr0qilJqXf6P-gatbGEw</recordid><startdate>20160701</startdate><enddate>20160701</enddate><creator>Beck, Michael</creator><creator>Sanders, James C</creator><creator>Ritt, Philipp</creator><creator>Reinfelder, Julia</creator><creator>Kuwert, Torsten</creator><general>Springer Nature B.V</general><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8AO</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20160701</creationdate><title>Longitudinal analysis of bone metabolism using SPECT/CT and ^sup 99m^Tc-diphosphono-propanedicarboxylic acid: comparison of visual and quantitative analysis</title><author>Beck, Michael ; Sanders, James C ; Ritt, Philipp ; Reinfelder, Julia ; Kuwert, Torsten</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_18652230993</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Beck, Michael</creatorcontrib><creatorcontrib>Sanders, James C</creatorcontrib><creatorcontrib>Ritt, Philipp</creatorcontrib><creatorcontrib>Reinfelder, Julia</creatorcontrib><creatorcontrib>Kuwert, Torsten</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest Pharma Collection</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>EJNMMI research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Beck, Michael</au><au>Sanders, James C</au><au>Ritt, Philipp</au><au>Reinfelder, Julia</au><au>Kuwert, Torsten</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Longitudinal analysis of bone metabolism using SPECT/CT and ^sup 99m^Tc-diphosphono-propanedicarboxylic acid: comparison of visual and quantitative analysis</atitle><jtitle>EJNMMI research</jtitle><date>2016-07-01</date><risdate>2016</risdate><volume>6</volume><issue>1</issue><spage>1</spage><pages>1-</pages><eissn>2191-219X</eissn><abstract>Background The therapy response of osseous metastases (OM) is commonly monitored by bone scintigraphies (BS). The aim of this study was to compare visual evaluation of changes in tracer uptake with quantitation in absolute units in OMs; 52 OMs from 19 patients who underwent BS with SPECT/CT at time points one and two (TP1/2) were analyzed retrospectively, with an average of 10.3 months between TP1 and 2. Tracer uptake in lesions was visually compared by two independent readers in both planar scintigraphies and SPECT/CT across both TPs and classified as regressive, stable, or progressive. Quantitative analysis was performed by measuring peak standardized uptake values (SUV). Based on quantitation, lesions were similarly classified as regressive (&gt;30 % decrease), progressive (&gt;30 % increase), or stable (rest). If available, uptake in reference regions in the lower thoracic or lumbar spine was used for normalization. Results In OMs at TP1 and TP2, mean SUVpeak (±SD) was found to be 20.4 (±20.8) and 16.4 (±11.5), respectively. For the reference region, mean SUVmean was 5.6 (±1.9) and 4.9 (±2.2). Agreement between quantitative and visual assessment was only moderate, with an average Cohen's kappa of 0.42 for planar scintigraphy and 0.62 for SPECT/CT. Discrepancies occurred in between 11 and 22 of the 52 lesions, depending on the reader and whether planar or SPECT imaging was considered. Conclusions Compared to measuring uptake in absolute units, visual evaluation of skeletal scintigraphies for change in tumor metabolism yields inconsistent results in roughly one third of the cases.</abstract><cop>Heidelberg</cop><pub>Springer Nature B.V</pub><doi>10.1186/s13550-016-0217-4</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2191-219X
ispartof EJNMMI research, 2016-07, Vol.6 (1), p.1
issn 2191-219X
language eng
recordid cdi_proquest_journals_1865223099
source DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; Springer Nature OA Free Journals; Springer Nature - Complete Springer Journals; PubMed Central
title Longitudinal analysis of bone metabolism using SPECT/CT and ^sup 99m^Tc-diphosphono-propanedicarboxylic acid: comparison of visual and quantitative analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T18%3A29%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Longitudinal%20analysis%20of%20bone%20metabolism%20using%20SPECT/CT%20and%20%5Esup%2099m%5ETc-diphosphono-propanedicarboxylic%20acid:%20comparison%20of%20visual%20and%20quantitative%20analysis&rft.jtitle=EJNMMI%20research&rft.au=Beck,%20Michael&rft.date=2016-07-01&rft.volume=6&rft.issue=1&rft.spage=1&rft.pages=1-&rft.eissn=2191-219X&rft_id=info:doi/10.1186/s13550-016-0217-4&rft_dat=%3Cproquest%3E4312248411%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1865223099&rft_id=info:pmid/&rfr_iscdi=true