Influence of test time on results of the impedance aggregometer Multiplate® analyser in dogs

The Multiplate® analyser is a relatively new impedance aggregometer designed for human medicine but was recently evaluated for canine blood. The aim of this study was to determine the influence of test time (i.e. measuring period) on reference values and the validity of measurement results in canine...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Comparative clinical pathology 2014-09, Vol.23 (5), p.1387-1393
Hauptverfasser: Abid, Monia, Kalbantner, Kerstin, Mischke, Reinhard
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1393
container_issue 5
container_start_page 1387
container_title Comparative clinical pathology
container_volume 23
creator Abid, Monia
Kalbantner, Kerstin
Mischke, Reinhard
description The Multiplate® analyser is a relatively new impedance aggregometer designed for human medicine but was recently evaluated for canine blood. The aim of this study was to determine the influence of test time (i.e. measuring period) on reference values and the validity of measurement results in canine blood. Based on blood samples of 83 healthy dogs, reference values for different test times (6, 8, 10 and 12 min) were established for area under the curve (AUC) and maximum aggregation values for adenosine diphosphate (ADP)-, collagen- and arachidonic acid-induced aggregation. The results of 134 samples of 117 dogs with various diseases and eight samples with reduced platelet function owing to treatment with the platelet aggregation inhibitor clopidogrel were calculated for different test times and classified as decreased, normal or increased. Maximum aggregation and AUC values increased significantly with increasing test time. Chi square test did not show significant differences between the various test times with regard to the number of increased and decreased measurement results for any agonist. All samples of dogs treated with clopidogrel and measured with the agonist ADP revealed decreased AUC values at any time point. The results of our study indicate that test time significantly influences AUC and maximum aggregation values but has limited influence on sensitivity of measurement results of canine blood using the investigated instrument.
doi_str_mv 10.1007/s00580-013-1795-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1563696451</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3437381131</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2314-54313e0649470dd5c7bb2f4e4e1abe531200488ef9cf454949b9cc0c3a70a0a53</originalsourceid><addsrcrecordid>eNp1kMtKxEAQRRtRcBz9AHcNrqNV6e48ljL4GBhxo-BGmk5SiRnysjtZzE_5EX6ZPUbEjauqupxbVF3GzhEuESC-cgAqgQBQBBinKpAHbIERJoGK1Mvhby_xmJ04twVAlQixYK_rrmwm6nLifclHciMf69YPHbfkpmZ03_ob8bodqDB70FSVpapvaSTLHzxTD40Z6fODm840O-fVuuNFX7lTdlSaxtHZT12y59ubp9V9sHm8W6-uN0EeCpSBkgIFQSRTGUNRqDzOsrCUJAlNRkpgCCCThMo0L6XyVJqleQ65MDEYMEos2cW8d7D9--Sf0Nt-sv4Yp1FFIkojqdBTOFO57Z2zVOrB1q2xO42g9ynqOUXtU9T7FLX0nnD2OM92Fdk_m_81fQFwxnWg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1563696451</pqid></control><display><type>article</type><title>Influence of test time on results of the impedance aggregometer Multiplate® analyser in dogs</title><source>SpringerLink Journals - AutoHoldings</source><creator>Abid, Monia ; Kalbantner, Kerstin ; Mischke, Reinhard</creator><creatorcontrib>Abid, Monia ; Kalbantner, Kerstin ; Mischke, Reinhard</creatorcontrib><description>The Multiplate® analyser is a relatively new impedance aggregometer designed for human medicine but was recently evaluated for canine blood. The aim of this study was to determine the influence of test time (i.e. measuring period) on reference values and the validity of measurement results in canine blood. Based on blood samples of 83 healthy dogs, reference values for different test times (6, 8, 10 and 12 min) were established for area under the curve (AUC) and maximum aggregation values for adenosine diphosphate (ADP)-, collagen- and arachidonic acid-induced aggregation. The results of 134 samples of 117 dogs with various diseases and eight samples with reduced platelet function owing to treatment with the platelet aggregation inhibitor clopidogrel were calculated for different test times and classified as decreased, normal or increased. Maximum aggregation and AUC values increased significantly with increasing test time. Chi square test did not show significant differences between the various test times with regard to the number of increased and decreased measurement results for any agonist. All samples of dogs treated with clopidogrel and measured with the agonist ADP revealed decreased AUC values at any time point. The results of our study indicate that test time significantly influences AUC and maximum aggregation values but has limited influence on sensitivity of measurement results of canine blood using the investigated instrument.</description><identifier>ISSN: 1618-5641</identifier><identifier>EISSN: 1618-565X</identifier><identifier>DOI: 10.1007/s00580-013-1795-4</identifier><language>eng</language><publisher>London: Springer London</publisher><subject>Hematology ; Medicine ; Medicine &amp; Public Health ; Oncology ; Original Article ; Pathology</subject><ispartof>Comparative clinical pathology, 2014-09, Vol.23 (5), p.1387-1393</ispartof><rights>Springer-Verlag London 2013</rights><rights>Springer-Verlag London 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2314-54313e0649470dd5c7bb2f4e4e1abe531200488ef9cf454949b9cc0c3a70a0a53</citedby><cites>FETCH-LOGICAL-c2314-54313e0649470dd5c7bb2f4e4e1abe531200488ef9cf454949b9cc0c3a70a0a53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00580-013-1795-4$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00580-013-1795-4$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids></links><search><creatorcontrib>Abid, Monia</creatorcontrib><creatorcontrib>Kalbantner, Kerstin</creatorcontrib><creatorcontrib>Mischke, Reinhard</creatorcontrib><title>Influence of test time on results of the impedance aggregometer Multiplate® analyser in dogs</title><title>Comparative clinical pathology</title><addtitle>Comp Clin Pathol</addtitle><description>The Multiplate® analyser is a relatively new impedance aggregometer designed for human medicine but was recently evaluated for canine blood. The aim of this study was to determine the influence of test time (i.e. measuring period) on reference values and the validity of measurement results in canine blood. Based on blood samples of 83 healthy dogs, reference values for different test times (6, 8, 10 and 12 min) were established for area under the curve (AUC) and maximum aggregation values for adenosine diphosphate (ADP)-, collagen- and arachidonic acid-induced aggregation. The results of 134 samples of 117 dogs with various diseases and eight samples with reduced platelet function owing to treatment with the platelet aggregation inhibitor clopidogrel were calculated for different test times and classified as decreased, normal or increased. Maximum aggregation and AUC values increased significantly with increasing test time. Chi square test did not show significant differences between the various test times with regard to the number of increased and decreased measurement results for any agonist. All samples of dogs treated with clopidogrel and measured with the agonist ADP revealed decreased AUC values at any time point. The results of our study indicate that test time significantly influences AUC and maximum aggregation values but has limited influence on sensitivity of measurement results of canine blood using the investigated instrument.</description><subject>Hematology</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Oncology</subject><subject>Original Article</subject><subject>Pathology</subject><issn>1618-5641</issn><issn>1618-565X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNp1kMtKxEAQRRtRcBz9AHcNrqNV6e48ljL4GBhxo-BGmk5SiRnysjtZzE_5EX6ZPUbEjauqupxbVF3GzhEuESC-cgAqgQBQBBinKpAHbIERJoGK1Mvhby_xmJ04twVAlQixYK_rrmwm6nLifclHciMf69YPHbfkpmZ03_ob8bodqDB70FSVpapvaSTLHzxTD40Z6fODm840O-fVuuNFX7lTdlSaxtHZT12y59ubp9V9sHm8W6-uN0EeCpSBkgIFQSRTGUNRqDzOsrCUJAlNRkpgCCCThMo0L6XyVJqleQ65MDEYMEos2cW8d7D9--Sf0Nt-sv4Yp1FFIkojqdBTOFO57Z2zVOrB1q2xO42g9ynqOUXtU9T7FLX0nnD2OM92Fdk_m_81fQFwxnWg</recordid><startdate>20140901</startdate><enddate>20140901</enddate><creator>Abid, Monia</creator><creator>Kalbantner, Kerstin</creator><creator>Mischke, Reinhard</creator><general>Springer London</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7T5</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H94</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>LK8</scope><scope>M0S</scope><scope>M7P</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20140901</creationdate><title>Influence of test time on results of the impedance aggregometer Multiplate® analyser in dogs</title><author>Abid, Monia ; Kalbantner, Kerstin ; Mischke, Reinhard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2314-54313e0649470dd5c7bb2f4e4e1abe531200488ef9cf454949b9cc0c3a70a0a53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Hematology</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Oncology</topic><topic>Original Article</topic><topic>Pathology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abid, Monia</creatorcontrib><creatorcontrib>Kalbantner, Kerstin</creatorcontrib><creatorcontrib>Mischke, Reinhard</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Immunology Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Biological Science Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Comparative clinical pathology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abid, Monia</au><au>Kalbantner, Kerstin</au><au>Mischke, Reinhard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of test time on results of the impedance aggregometer Multiplate® analyser in dogs</atitle><jtitle>Comparative clinical pathology</jtitle><stitle>Comp Clin Pathol</stitle><date>2014-09-01</date><risdate>2014</risdate><volume>23</volume><issue>5</issue><spage>1387</spage><epage>1393</epage><pages>1387-1393</pages><issn>1618-5641</issn><eissn>1618-565X</eissn><abstract>The Multiplate® analyser is a relatively new impedance aggregometer designed for human medicine but was recently evaluated for canine blood. The aim of this study was to determine the influence of test time (i.e. measuring period) on reference values and the validity of measurement results in canine blood. Based on blood samples of 83 healthy dogs, reference values for different test times (6, 8, 10 and 12 min) were established for area under the curve (AUC) and maximum aggregation values for adenosine diphosphate (ADP)-, collagen- and arachidonic acid-induced aggregation. The results of 134 samples of 117 dogs with various diseases and eight samples with reduced platelet function owing to treatment with the platelet aggregation inhibitor clopidogrel were calculated for different test times and classified as decreased, normal or increased. Maximum aggregation and AUC values increased significantly with increasing test time. Chi square test did not show significant differences between the various test times with regard to the number of increased and decreased measurement results for any agonist. All samples of dogs treated with clopidogrel and measured with the agonist ADP revealed decreased AUC values at any time point. The results of our study indicate that test time significantly influences AUC and maximum aggregation values but has limited influence on sensitivity of measurement results of canine blood using the investigated instrument.</abstract><cop>London</cop><pub>Springer London</pub><doi>10.1007/s00580-013-1795-4</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1618-5641
ispartof Comparative clinical pathology, 2014-09, Vol.23 (5), p.1387-1393
issn 1618-5641
1618-565X
language eng
recordid cdi_proquest_journals_1563696451
source SpringerLink Journals - AutoHoldings
subjects Hematology
Medicine
Medicine & Public Health
Oncology
Original Article
Pathology
title Influence of test time on results of the impedance aggregometer Multiplate® analyser in dogs
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T20%3A27%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20test%20time%20on%20results%20of%20the%20impedance%20aggregometer%20Multiplate%C2%AE%20analyser%20in%20dogs&rft.jtitle=Comparative%20clinical%20pathology&rft.au=Abid,%20Monia&rft.date=2014-09-01&rft.volume=23&rft.issue=5&rft.spage=1387&rft.epage=1393&rft.pages=1387-1393&rft.issn=1618-5641&rft.eissn=1618-565X&rft_id=info:doi/10.1007/s00580-013-1795-4&rft_dat=%3Cproquest_cross%3E3437381131%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1563696451&rft_id=info:pmid/&rfr_iscdi=true