Operation Experience with a 20kW SOFC System
Systems based on planar SOFC stacks have a great potential to become compact high efficient power plants. At Forschungszentrum Julich system technology is under development aiming at a 20kW demonstration plant. An important challenge is to realize a compact and efficient system. To achieve this, Jul...
Gespeichert in:
Veröffentlicht in: | Fuel cells (Weinheim an der Bergstrasse, Germany) Germany), 2014-06, Vol.14 (3), p.489 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 3 |
container_start_page | 489 |
container_title | Fuel cells (Weinheim an der Bergstrasse, Germany) |
container_volume | 14 |
creator | Peters, Ro Blum, L Deja, R Hoven, I Tiedemann, W Kupper, S Stolten, D |
description | Systems based on planar SOFC stacks have a great potential to become compact high efficient power plants. At Forschungszentrum Julich system technology is under development aiming at a 20kW demonstration plant. An important challenge is to realize a compact and efficient system. To achieve this, Julich has invented an Integrated Module, which incorporates all hot parts of the system. After a few years of development four stacks with a nominal power of 5kW were assembled and characterized with proper quality. After integrating them into the system operation was started and 21.3kW gross power were achieved. Because of a leakage in the periphery the test had to be interrupted after 550h of operation under load. Because repair would have taken too long, the test was continued with two modules of 5kW power each. The system was in operation under load for 4,000h. [PUBLICATION ABSTRACT] |
doi_str_mv | 10.1002/fuce.201300184 |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_1536687033</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3336816241</sourcerecordid><originalsourceid>FETCH-LOGICAL-p113t-4f12faa1c949adeb6e550e60fddba5bd612b00c4f6d2be7f6b97cb9dacfb312f3</originalsourceid><addsrcrecordid>eNo9jUtLw0AUhQdRsFa3rgfcmnrvvJIsJbQqFLKo4rLM4w6mahIzCeq_N6C4Ot_ifOcwdomwQgBxEydPKwEoAbBQR2yBBnVmCq2O_1mZU3aW0mGu5EWhFuy67mmwY9O1fP01Y0OtJ_7ZjC_ccgGvz3xXbyq--04jvZ-zk2jfEl385ZI9bdaP1X22re8eqttt1iPKMVMRRbQWfalKG8gZ0hrIQAzBWe2CQeEAvIomCEd5NK7MvSuD9dHJWZVLdvW72w_dx0Rp3B-6aWjnyz1qaUyRg5TyBz2CRIc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1536687033</pqid></control><display><type>article</type><title>Operation Experience with a 20kW SOFC System</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Peters, Ro ; Blum, L ; Deja, R ; Hoven, I ; Tiedemann, W ; Kupper, S ; Stolten, D</creator><creatorcontrib>Peters, Ro ; Blum, L ; Deja, R ; Hoven, I ; Tiedemann, W ; Kupper, S ; Stolten, D</creatorcontrib><description>Systems based on planar SOFC stacks have a great potential to become compact high efficient power plants. At Forschungszentrum Julich system technology is under development aiming at a 20kW demonstration plant. An important challenge is to realize a compact and efficient system. To achieve this, Julich has invented an Integrated Module, which incorporates all hot parts of the system. After a few years of development four stacks with a nominal power of 5kW were assembled and characterized with proper quality. After integrating them into the system operation was started and 21.3kW gross power were achieved. Because of a leakage in the periphery the test had to be interrupted after 550h of operation under load. Because repair would have taken too long, the test was continued with two modules of 5kW power each. The system was in operation under load for 4,000h. [PUBLICATION ABSTRACT]</description><identifier>ISSN: 1615-6846</identifier><identifier>EISSN: 1615-6854</identifier><identifier>DOI: 10.1002/fuce.201300184</identifier><language>eng</language><publisher>Weinheim: Wiley Subscription Services, Inc</publisher><subject>Solid oxide fuel cells</subject><ispartof>Fuel cells (Weinheim an der Bergstrasse, Germany), 2014-06, Vol.14 (3), p.489</ispartof><rights>Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Peters, Ro</creatorcontrib><creatorcontrib>Blum, L</creatorcontrib><creatorcontrib>Deja, R</creatorcontrib><creatorcontrib>Hoven, I</creatorcontrib><creatorcontrib>Tiedemann, W</creatorcontrib><creatorcontrib>Kupper, S</creatorcontrib><creatorcontrib>Stolten, D</creatorcontrib><title>Operation Experience with a 20kW SOFC System</title><title>Fuel cells (Weinheim an der Bergstrasse, Germany)</title><description>Systems based on planar SOFC stacks have a great potential to become compact high efficient power plants. At Forschungszentrum Julich system technology is under development aiming at a 20kW demonstration plant. An important challenge is to realize a compact and efficient system. To achieve this, Julich has invented an Integrated Module, which incorporates all hot parts of the system. After a few years of development four stacks with a nominal power of 5kW were assembled and characterized with proper quality. After integrating them into the system operation was started and 21.3kW gross power were achieved. Because of a leakage in the periphery the test had to be interrupted after 550h of operation under load. Because repair would have taken too long, the test was continued with two modules of 5kW power each. The system was in operation under load for 4,000h. [PUBLICATION ABSTRACT]</description><subject>Solid oxide fuel cells</subject><issn>1615-6846</issn><issn>1615-6854</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNo9jUtLw0AUhQdRsFa3rgfcmnrvvJIsJbQqFLKo4rLM4w6mahIzCeq_N6C4Ot_ifOcwdomwQgBxEydPKwEoAbBQR2yBBnVmCq2O_1mZU3aW0mGu5EWhFuy67mmwY9O1fP01Y0OtJ_7ZjC_ccgGvz3xXbyq--04jvZ-zk2jfEl385ZI9bdaP1X22re8eqttt1iPKMVMRRbQWfalKG8gZ0hrIQAzBWe2CQeEAvIomCEd5NK7MvSuD9dHJWZVLdvW72w_dx0Rp3B-6aWjnyz1qaUyRg5TyBz2CRIc</recordid><startdate>20140601</startdate><enddate>20140601</enddate><creator>Peters, Ro</creator><creator>Blum, L</creator><creator>Deja, R</creator><creator>Hoven, I</creator><creator>Tiedemann, W</creator><creator>Kupper, S</creator><creator>Stolten, D</creator><general>Wiley Subscription Services, Inc</general><scope>7SP</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20140601</creationdate><title>Operation Experience with a 20kW SOFC System</title><author>Peters, Ro ; Blum, L ; Deja, R ; Hoven, I ; Tiedemann, W ; Kupper, S ; Stolten, D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p113t-4f12faa1c949adeb6e550e60fddba5bd612b00c4f6d2be7f6b97cb9dacfb312f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Solid oxide fuel cells</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Peters, Ro</creatorcontrib><creatorcontrib>Blum, L</creatorcontrib><creatorcontrib>Deja, R</creatorcontrib><creatorcontrib>Hoven, I</creatorcontrib><creatorcontrib>Tiedemann, W</creatorcontrib><creatorcontrib>Kupper, S</creatorcontrib><creatorcontrib>Stolten, D</creatorcontrib><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Fuel cells (Weinheim an der Bergstrasse, Germany)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Peters, Ro</au><au>Blum, L</au><au>Deja, R</au><au>Hoven, I</au><au>Tiedemann, W</au><au>Kupper, S</au><au>Stolten, D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Operation Experience with a 20kW SOFC System</atitle><jtitle>Fuel cells (Weinheim an der Bergstrasse, Germany)</jtitle><date>2014-06-01</date><risdate>2014</risdate><volume>14</volume><issue>3</issue><spage>489</spage><pages>489-</pages><issn>1615-6846</issn><eissn>1615-6854</eissn><abstract>Systems based on planar SOFC stacks have a great potential to become compact high efficient power plants. At Forschungszentrum Julich system technology is under development aiming at a 20kW demonstration plant. An important challenge is to realize a compact and efficient system. To achieve this, Julich has invented an Integrated Module, which incorporates all hot parts of the system. After a few years of development four stacks with a nominal power of 5kW were assembled and characterized with proper quality. After integrating them into the system operation was started and 21.3kW gross power were achieved. Because of a leakage in the periphery the test had to be interrupted after 550h of operation under load. Because repair would have taken too long, the test was continued with two modules of 5kW power each. The system was in operation under load for 4,000h. [PUBLICATION ABSTRACT]</abstract><cop>Weinheim</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1002/fuce.201300184</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1615-6846 |
ispartof | Fuel cells (Weinheim an der Bergstrasse, Germany), 2014-06, Vol.14 (3), p.489 |
issn | 1615-6846 1615-6854 |
language | eng |
recordid | cdi_proquest_journals_1536687033 |
source | Wiley Online Library Journals Frontfile Complete |
subjects | Solid oxide fuel cells |
title | Operation Experience with a 20kW SOFC System |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T03%3A22%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Operation%20Experience%20with%20a%2020kW%20SOFC%20System&rft.jtitle=Fuel%20cells%20(Weinheim%20an%20der%20Bergstrasse,%20Germany)&rft.au=Peters,%20Ro&rft.date=2014-06-01&rft.volume=14&rft.issue=3&rft.spage=489&rft.pages=489-&rft.issn=1615-6846&rft.eissn=1615-6854&rft_id=info:doi/10.1002/fuce.201300184&rft_dat=%3Cproquest%3E3336816241%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1536687033&rft_id=info:pmid/&rfr_iscdi=true |