Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump

This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY 2008, Vol.39(6), pp.116-123
Hauptverfasser: KOJIMA, Eiichi, YAMAZAKI, Toru, ANDO, Tsuyoshi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 123
container_issue 6
container_start_page 116
container_title TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY
container_volume 39
creator KOJIMA, Eiichi
YAMAZAKI, Toru
ANDO, Tsuyoshi
description This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump.
doi_str_mv 10.5739/jfps.39.116
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1475599409</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3176696441</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1586-efdfa54e86470cd49f56ac21f79236da0efc6a92fd1de061dd899d8b78cc3f503</originalsourceid><addsrcrecordid>eNo9kNFLwzAQxosoOHRP_gMBH6Uzadq0eVO2uQ0GDpzPJUsurqNrapKqffJfN6Oyl7uD73ffcV8U3RE8yXLKHw-6dRPKJ4Swi2hEaMrjHCfJZZiLAseUJOQ6GjtX7TDGnJGMJ6PodwZfUJv2CI1HRiOB3rxolLAKbcF5tLFGguosIG_Q_KcFW51QUdc9moEHe6yaoO0BrZo92JPLpqud8JVp0MZ8g0ULaMAKDwrt-uC_7JUVXV3JAB7b2-hKi9rB-L_fRO8v8-10Ga9fF6vp8zqWJCtYDFppkaVQsDTHUqVcZ0zIhOicJ5QpgUFLJniiFVGAGVGq4FwVu7yQkuoM05vofvBtrfnswmflwXS2CSdLkuZZxnmKeaAeBkpa45wFXbbhX2H7kuDyFHJ5CrkMPYQc6KeBPjgvPuDMCusrWcOZZUMJK2dJ7oUtoaF_lyyJxA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1475599409</pqid></control><display><type>article</type><title>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</title><source>J-STAGE Free</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>KOJIMA, Eiichi ; YAMAZAKI, Toru ; ANDO, Tsuyoshi</creator><creatorcontrib>KOJIMA, Eiichi ; YAMAZAKI, Toru ; ANDO, Tsuyoshi</creatorcontrib><description>This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump.</description><identifier>ISSN: 1880-3121</identifier><identifier>EISSN: 1349-7022</identifier><identifier>DOI: 10.5739/jfps.39.116</identifier><language>eng</language><publisher>Tokyo: The Japan Fluid Power System Society</publisher><subject>Fluid-borne noise ; Hydraulic pump ; Pressure pulsation ; Pulsation power ; Standard test method</subject><ispartof>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY, 2008, Vol.39(6), pp.116-123</ispartof><rights>2009 by The Japan Fluid Power System Society</rights><rights>Copyright Japan Science and Technology Agency 2008</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1586-efdfa54e86470cd49f56ac21f79236da0efc6a92fd1de061dd899d8b78cc3f503</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,4010,27900,27901,27902</link.rule.ids></links><search><creatorcontrib>KOJIMA, Eiichi</creatorcontrib><creatorcontrib>YAMAZAKI, Toru</creatorcontrib><creatorcontrib>ANDO, Tsuyoshi</creatorcontrib><title>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</title><title>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</title><addtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</addtitle><description>This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump.</description><subject>Fluid-borne noise</subject><subject>Hydraulic pump</subject><subject>Pressure pulsation</subject><subject>Pulsation power</subject><subject>Standard test method</subject><issn>1880-3121</issn><issn>1349-7022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNo9kNFLwzAQxosoOHRP_gMBH6Uzadq0eVO2uQ0GDpzPJUsurqNrapKqffJfN6Oyl7uD73ffcV8U3RE8yXLKHw-6dRPKJ4Swi2hEaMrjHCfJZZiLAseUJOQ6GjtX7TDGnJGMJ6PodwZfUJv2CI1HRiOB3rxolLAKbcF5tLFGguosIG_Q_KcFW51QUdc9moEHe6yaoO0BrZo92JPLpqud8JVp0MZ8g0ULaMAKDwrt-uC_7JUVXV3JAB7b2-hKi9rB-L_fRO8v8-10Ga9fF6vp8zqWJCtYDFppkaVQsDTHUqVcZ0zIhOicJ5QpgUFLJniiFVGAGVGq4FwVu7yQkuoM05vofvBtrfnswmflwXS2CSdLkuZZxnmKeaAeBkpa45wFXbbhX2H7kuDyFHJ5CrkMPYQc6KeBPjgvPuDMCusrWcOZZUMJK2dJ7oUtoaF_lyyJxA</recordid><startdate>2008</startdate><enddate>2008</enddate><creator>KOJIMA, Eiichi</creator><creator>YAMAZAKI, Toru</creator><creator>ANDO, Tsuyoshi</creator><general>The Japan Fluid Power System Society</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2008</creationdate><title>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</title><author>KOJIMA, Eiichi ; YAMAZAKI, Toru ; ANDO, Tsuyoshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1586-efdfa54e86470cd49f56ac21f79236da0efc6a92fd1de061dd899d8b78cc3f503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Fluid-borne noise</topic><topic>Hydraulic pump</topic><topic>Pressure pulsation</topic><topic>Pulsation power</topic><topic>Standard test method</topic><toplevel>online_resources</toplevel><creatorcontrib>KOJIMA, Eiichi</creatorcontrib><creatorcontrib>YAMAZAKI, Toru</creatorcontrib><creatorcontrib>ANDO, Tsuyoshi</creatorcontrib><collection>CrossRef</collection><jtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KOJIMA, Eiichi</au><au>YAMAZAKI, Toru</au><au>ANDO, Tsuyoshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</atitle><jtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</jtitle><addtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</addtitle><date>2008</date><risdate>2008</risdate><volume>39</volume><issue>6</issue><spage>116</spage><epage>123</epage><pages>116-123</pages><issn>1880-3121</issn><eissn>1349-7022</eissn><abstract>This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump.</abstract><cop>Tokyo</cop><pub>The Japan Fluid Power System Society</pub><doi>10.5739/jfps.39.116</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1880-3121
ispartof TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY, 2008, Vol.39(6), pp.116-123
issn 1880-3121
1349-7022
language eng
recordid cdi_proquest_journals_1475599409
source J-STAGE Free; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Fluid-borne noise
Hydraulic pump
Pressure pulsation
Pulsation power
Standard test method
title Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T14%3A40%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20Standard%20Test%20Procedure%20to%20Experimentally%20Determine%20the%20Inherent%20Pulsation%20Power%20Generated%20by%20a%20Hydraulic%20Pump&rft.jtitle=TRANSACTIONS%20OF%20THE%20JAPAN%20FLUID%20POWER%20SYSTEM%20SOCIETY&rft.au=KOJIMA,%20Eiichi&rft.date=2008&rft.volume=39&rft.issue=6&rft.spage=116&rft.epage=123&rft.pages=116-123&rft.issn=1880-3121&rft.eissn=1349-7022&rft_id=info:doi/10.5739/jfps.39.116&rft_dat=%3Cproquest_cross%3E3176696441%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1475599409&rft_id=info:pmid/&rfr_iscdi=true