Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump
This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating...
Gespeichert in:
Veröffentlicht in: | TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY 2008, Vol.39(6), pp.116-123 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 123 |
---|---|
container_issue | 6 |
container_start_page | 116 |
container_title | TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY |
container_volume | 39 |
creator | KOJIMA, Eiichi YAMAZAKI, Toru ANDO, Tsuyoshi |
description | This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump. |
doi_str_mv | 10.5739/jfps.39.116 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1475599409</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3176696441</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1586-efdfa54e86470cd49f56ac21f79236da0efc6a92fd1de061dd899d8b78cc3f503</originalsourceid><addsrcrecordid>eNo9kNFLwzAQxosoOHRP_gMBH6Uzadq0eVO2uQ0GDpzPJUsurqNrapKqffJfN6Oyl7uD73ffcV8U3RE8yXLKHw-6dRPKJ4Swi2hEaMrjHCfJZZiLAseUJOQ6GjtX7TDGnJGMJ6PodwZfUJv2CI1HRiOB3rxolLAKbcF5tLFGguosIG_Q_KcFW51QUdc9moEHe6yaoO0BrZo92JPLpqud8JVp0MZ8g0ULaMAKDwrt-uC_7JUVXV3JAB7b2-hKi9rB-L_fRO8v8-10Ga9fF6vp8zqWJCtYDFppkaVQsDTHUqVcZ0zIhOicJ5QpgUFLJniiFVGAGVGq4FwVu7yQkuoM05vofvBtrfnswmflwXS2CSdLkuZZxnmKeaAeBkpa45wFXbbhX2H7kuDyFHJ5CrkMPYQc6KeBPjgvPuDMCusrWcOZZUMJK2dJ7oUtoaF_lyyJxA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1475599409</pqid></control><display><type>article</type><title>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</title><source>J-STAGE Free</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>KOJIMA, Eiichi ; YAMAZAKI, Toru ; ANDO, Tsuyoshi</creator><creatorcontrib>KOJIMA, Eiichi ; YAMAZAKI, Toru ; ANDO, Tsuyoshi</creatorcontrib><description>This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump.</description><identifier>ISSN: 1880-3121</identifier><identifier>EISSN: 1349-7022</identifier><identifier>DOI: 10.5739/jfps.39.116</identifier><language>eng</language><publisher>Tokyo: The Japan Fluid Power System Society</publisher><subject>Fluid-borne noise ; Hydraulic pump ; Pressure pulsation ; Pulsation power ; Standard test method</subject><ispartof>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY, 2008, Vol.39(6), pp.116-123</ispartof><rights>2009 by The Japan Fluid Power System Society</rights><rights>Copyright Japan Science and Technology Agency 2008</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1586-efdfa54e86470cd49f56ac21f79236da0efc6a92fd1de061dd899d8b78cc3f503</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,4010,27900,27901,27902</link.rule.ids></links><search><creatorcontrib>KOJIMA, Eiichi</creatorcontrib><creatorcontrib>YAMAZAKI, Toru</creatorcontrib><creatorcontrib>ANDO, Tsuyoshi</creatorcontrib><title>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</title><title>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</title><addtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</addtitle><description>This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump.</description><subject>Fluid-borne noise</subject><subject>Hydraulic pump</subject><subject>Pressure pulsation</subject><subject>Pulsation power</subject><subject>Standard test method</subject><issn>1880-3121</issn><issn>1349-7022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNo9kNFLwzAQxosoOHRP_gMBH6Uzadq0eVO2uQ0GDpzPJUsurqNrapKqffJfN6Oyl7uD73ffcV8U3RE8yXLKHw-6dRPKJ4Swi2hEaMrjHCfJZZiLAseUJOQ6GjtX7TDGnJGMJ6PodwZfUJv2CI1HRiOB3rxolLAKbcF5tLFGguosIG_Q_KcFW51QUdc9moEHe6yaoO0BrZo92JPLpqud8JVp0MZ8g0ULaMAKDwrt-uC_7JUVXV3JAB7b2-hKi9rB-L_fRO8v8-10Ga9fF6vp8zqWJCtYDFppkaVQsDTHUqVcZ0zIhOicJ5QpgUFLJniiFVGAGVGq4FwVu7yQkuoM05vofvBtrfnswmflwXS2CSdLkuZZxnmKeaAeBkpa45wFXbbhX2H7kuDyFHJ5CrkMPYQc6KeBPjgvPuDMCusrWcOZZUMJK2dJ7oUtoaF_lyyJxA</recordid><startdate>2008</startdate><enddate>2008</enddate><creator>KOJIMA, Eiichi</creator><creator>YAMAZAKI, Toru</creator><creator>ANDO, Tsuyoshi</creator><general>The Japan Fluid Power System Society</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2008</creationdate><title>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</title><author>KOJIMA, Eiichi ; YAMAZAKI, Toru ; ANDO, Tsuyoshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1586-efdfa54e86470cd49f56ac21f79236da0efc6a92fd1de061dd899d8b78cc3f503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Fluid-borne noise</topic><topic>Hydraulic pump</topic><topic>Pressure pulsation</topic><topic>Pulsation power</topic><topic>Standard test method</topic><toplevel>online_resources</toplevel><creatorcontrib>KOJIMA, Eiichi</creatorcontrib><creatorcontrib>YAMAZAKI, Toru</creatorcontrib><creatorcontrib>ANDO, Tsuyoshi</creatorcontrib><collection>CrossRef</collection><jtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KOJIMA, Eiichi</au><au>YAMAZAKI, Toru</au><au>ANDO, Tsuyoshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump</atitle><jtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</jtitle><addtitle>TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY</addtitle><date>2008</date><risdate>2008</risdate><volume>39</volume><issue>6</issue><spage>116</spage><epage>123</epage><pages>116-123</pages><issn>1880-3121</issn><eissn>1349-7022</eissn><abstract>This paper is concerned with the experimental determination of an inherent pulsation power level generated by a hydraulic pump, using both the test method originally developed for the measurement of fluid pulsation power in a pipeline and the theoretically derived conversion equation for eliminating the influence of a hydraulic circuit. The suitability of the test procedure as a standard method for assessment of an inherent source pulsation power of a hydraulic pump was confirmed. First, it was found that the pulsation power in a pipeline can be measured using a pressure sensor unit called a “pulsation intensity probe” with the same measurement principle as the conventional sound intensity probe, with good repeatability and with sufficient accuracy for practical usage. Next, the standard test procedure for determining the inherent source pulsation power of a hydraulic pump, which is independent of a hydraulic circuit connected to the pump, from the measurements of the pulsation power in a reference pipe was proposed. Finally, it was verified from the experimental measurements and simulations that this proposed standard test method was very useful for both the absolute and relative assessments of source pulsation power level of a hydraulic pump.</abstract><cop>Tokyo</cop><pub>The Japan Fluid Power System Society</pub><doi>10.5739/jfps.39.116</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1880-3121 |
ispartof | TRANSACTIONS OF THE JAPAN FLUID POWER SYSTEM SOCIETY, 2008, Vol.39(6), pp.116-123 |
issn | 1880-3121 1349-7022 |
language | eng |
recordid | cdi_proquest_journals_1475599409 |
source | J-STAGE Free; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Fluid-borne noise Hydraulic pump Pressure pulsation Pulsation power Standard test method |
title | Development of a Standard Test Procedure to Experimentally Determine the Inherent Pulsation Power Generated by a Hydraulic Pump |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T14%3A40%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20Standard%20Test%20Procedure%20to%20Experimentally%20Determine%20the%20Inherent%20Pulsation%20Power%20Generated%20by%20a%20Hydraulic%20Pump&rft.jtitle=TRANSACTIONS%20OF%20THE%20JAPAN%20FLUID%20POWER%20SYSTEM%20SOCIETY&rft.au=KOJIMA,%20Eiichi&rft.date=2008&rft.volume=39&rft.issue=6&rft.spage=116&rft.epage=123&rft.pages=116-123&rft.issn=1880-3121&rft.eissn=1349-7022&rft_id=info:doi/10.5739/jfps.39.116&rft_dat=%3Cproquest_cross%3E3176696441%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1475599409&rft_id=info:pmid/&rfr_iscdi=true |