Test of the High-Field [Formula Omitted] Dipole Magnet HD3b
We report test results for the one meter long dipole HD3b, a block-type accelerator quality [Formula Omitted] magnet built at LBNL with operational bore fields in the range of 13-15 T. The magnet is an upgrade of the previously reported HD2 and HD3a versions, with several modifications implemented t...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2014-06, Vol.24 (3), p.1 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report test results for the one meter long dipole HD3b, a block-type accelerator quality [Formula Omitted] magnet built at LBNL with operational bore fields in the range of 13-15 T. The magnet is an upgrade of the previously reported HD2 and HD3a versions, with several modifications implemented to improve conductor positioning, reduce cable "hard-way" bending radius, and strengthen electrical insulation between cables and coil parts. The magnet exhibited long training behavior, but showed a good "memory" of the trained state upon thermal cycling. Ramp-rate dependence of the quench current, field quality performance characteristics, and protection heater studies were conducted. Quench propagation velocity and quench locations were determined based on the voltage signals; quench localization was further improved using inductive quench antenna and acoustic emission sensors. Short- and long-term acoustic precursors to quenching were observed. |
---|---|
ISSN: | 1051-8223 1558-2515 |
DOI: | 10.1109/TASC.2013.2285881 |