Hip sonography update. Quality-management, catastrophes - tips and tricks
Hip sonography is today considered to be the diagnostic standard tool for developmental dysplasia of the hip (DDH) diagnosis. In Germany special commissions control the quality of the sonograms according to checklists to keep the standard high and to avoid over- and under - treatment. This paper lis...
Gespeichert in:
Veröffentlicht in: | Medical ultrasonography 2013-12, Vol.15 (4), p.299-303 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 303 |
---|---|
container_issue | 4 |
container_start_page | 299 |
container_title | Medical ultrasonography |
container_volume | 15 |
creator | Graf, Reinhard Mohajer, Mohammad Plattner, Florian |
description | Hip sonography is today considered to be the diagnostic standard tool for developmental dysplasia of the hip (DDH) diagnosis. In Germany special commissions control the quality of the sonograms according to checklists to keep the standard high and to avoid over- and under - treatment. This paper lists tips and tricks to avoid typical mistakes according to these results.
In 8 German countries the quality of sonograms used to diagnose DDH was checked according to special checklists. An additional 250 medical doctors (pediatricians, radiologists, orthopaedic surgeons) were asked to classify 4 sonograms by measuring and typing. From the same group the projection (standing left, standing right, horizontal-cranial left, horizontal-cranial right) was checked according to the correct diagnosis in the shortest time.
In 1.6 % - 43.7% the licence for hip sonography was withdrawn by the German commission. The best projection with the lowest rate of wrong interpretation was the "standing right"-projection. Most of the mistakes were made because of a wrong anatomical identification and usability check.
Hip sonography must be trained by authorized teachers. The quality of the sonograms must be controlled according to checklists. The bedside teaching without control leads to a systematic teaching of mistakes and finally catastrophes. |
doi_str_mv | 10.11152/mu.2013.2066.154.rg2 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1464730292</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3144875871</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-ec873cfa221104548178bc9aaa7c72d0700b20ab66fd85ef7e92993cfee8c1b03</originalsourceid><addsrcrecordid>eNo9kF1LwzAUhoMobsz9BCXgra05SZqklzKcGwxE0OuQpulWXT9M0ov9ezs3vTmHA-_zHngQugWSAkBGH5shpQTYOIRIIeOp39ILND2eiRKcXaIpKM4TDpJO0DyEuiCUgZBZTq7RhHKqBMn5FK1XdY9D13Zbb_rdAQ99aaJL8dtg9nU8JI1pzdY1ro0P2JpoQvRdv3MBJzjWfcCmLXH0tf0KN-iqMvvg5uc9Qx_L5_fFKtm8vqwXT5vEMsVj4qySzFaGUgDCM65AqsLmxhhpJS2JJKSgxBRCVKXKXCVdTvN8JJxTFgrCZuj-1Nv77ntwIerPbvDt-FIDF1wyQnM6prJTyvouBO8q3fu6Mf6ggehfh7oZ9NGhPkrTo0M9Ohy5u3P7UDSu_Kf-jLEfdUltpw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1464730292</pqid></control><display><type>article</type><title>Hip sonography update. Quality-management, catastrophes - tips and tricks</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Graf, Reinhard ; Mohajer, Mohammad ; Plattner, Florian</creator><creatorcontrib>Graf, Reinhard ; Mohajer, Mohammad ; Plattner, Florian</creatorcontrib><description>Hip sonography is today considered to be the diagnostic standard tool for developmental dysplasia of the hip (DDH) diagnosis. In Germany special commissions control the quality of the sonograms according to checklists to keep the standard high and to avoid over- and under - treatment. This paper lists tips and tricks to avoid typical mistakes according to these results.
In 8 German countries the quality of sonograms used to diagnose DDH was checked according to special checklists. An additional 250 medical doctors (pediatricians, radiologists, orthopaedic surgeons) were asked to classify 4 sonograms by measuring and typing. From the same group the projection (standing left, standing right, horizontal-cranial left, horizontal-cranial right) was checked according to the correct diagnosis in the shortest time.
In 1.6 % - 43.7% the licence for hip sonography was withdrawn by the German commission. The best projection with the lowest rate of wrong interpretation was the "standing right"-projection. Most of the mistakes were made because of a wrong anatomical identification and usability check.
Hip sonography must be trained by authorized teachers. The quality of the sonograms must be controlled according to checklists. The bedside teaching without control leads to a systematic teaching of mistakes and finally catastrophes.</description><identifier>ISSN: 1844-4172</identifier><identifier>EISSN: 2066-8643</identifier><identifier>DOI: 10.11152/mu.2013.2066.154.rg2</identifier><identifier>PMID: 24286094</identifier><language>eng</language><publisher>Romania: Romanian Society of Ultrasonography in Medicine and Biology</publisher><subject>Algorithms ; Checklist ; Female ; Hip Dislocation, Congenital - diagnostic imaging ; Hip Joint - abnormalities ; Hip Joint - diagnostic imaging ; Humans ; Image Enhancement - methods ; Infant ; Infant, Newborn ; Male ; Patient Positioning - methods ; Ultrasonography - methods</subject><ispartof>Medical ultrasonography, 2013-12, Vol.15 (4), p.299-303</ispartof><rights>Copyright Romanian Society of Ultrasonography in Medicine and Biology 2013</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-ec873cfa221104548178bc9aaa7c72d0700b20ab66fd85ef7e92993cfee8c1b03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24286094$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Graf, Reinhard</creatorcontrib><creatorcontrib>Mohajer, Mohammad</creatorcontrib><creatorcontrib>Plattner, Florian</creatorcontrib><title>Hip sonography update. Quality-management, catastrophes - tips and tricks</title><title>Medical ultrasonography</title><addtitle>Med Ultrason</addtitle><description>Hip sonography is today considered to be the diagnostic standard tool for developmental dysplasia of the hip (DDH) diagnosis. In Germany special commissions control the quality of the sonograms according to checklists to keep the standard high and to avoid over- and under - treatment. This paper lists tips and tricks to avoid typical mistakes according to these results.
In 8 German countries the quality of sonograms used to diagnose DDH was checked according to special checklists. An additional 250 medical doctors (pediatricians, radiologists, orthopaedic surgeons) were asked to classify 4 sonograms by measuring and typing. From the same group the projection (standing left, standing right, horizontal-cranial left, horizontal-cranial right) was checked according to the correct diagnosis in the shortest time.
In 1.6 % - 43.7% the licence for hip sonography was withdrawn by the German commission. The best projection with the lowest rate of wrong interpretation was the "standing right"-projection. Most of the mistakes were made because of a wrong anatomical identification and usability check.
Hip sonography must be trained by authorized teachers. The quality of the sonograms must be controlled according to checklists. The bedside teaching without control leads to a systematic teaching of mistakes and finally catastrophes.</description><subject>Algorithms</subject><subject>Checklist</subject><subject>Female</subject><subject>Hip Dislocation, Congenital - diagnostic imaging</subject><subject>Hip Joint - abnormalities</subject><subject>Hip Joint - diagnostic imaging</subject><subject>Humans</subject><subject>Image Enhancement - methods</subject><subject>Infant</subject><subject>Infant, Newborn</subject><subject>Male</subject><subject>Patient Positioning - methods</subject><subject>Ultrasonography - methods</subject><issn>1844-4172</issn><issn>2066-8643</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNo9kF1LwzAUhoMobsz9BCXgra05SZqklzKcGwxE0OuQpulWXT9M0ov9ezs3vTmHA-_zHngQugWSAkBGH5shpQTYOIRIIeOp39ILND2eiRKcXaIpKM4TDpJO0DyEuiCUgZBZTq7RhHKqBMn5FK1XdY9D13Zbb_rdAQ99aaJL8dtg9nU8JI1pzdY1ro0P2JpoQvRdv3MBJzjWfcCmLXH0tf0KN-iqMvvg5uc9Qx_L5_fFKtm8vqwXT5vEMsVj4qySzFaGUgDCM65AqsLmxhhpJS2JJKSgxBRCVKXKXCVdTvN8JJxTFgrCZuj-1Nv77ntwIerPbvDt-FIDF1wyQnM6prJTyvouBO8q3fu6Mf6ggehfh7oZ9NGhPkrTo0M9Ohy5u3P7UDSu_Kf-jLEfdUltpw</recordid><startdate>20131201</startdate><enddate>20131201</enddate><creator>Graf, Reinhard</creator><creator>Mohajer, Mohammad</creator><creator>Plattner, Florian</creator><general>Romanian Society of Ultrasonography in Medicine and Biology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BYOGL</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20131201</creationdate><title>Hip sonography update. Quality-management, catastrophes - tips and tricks</title><author>Graf, Reinhard ; Mohajer, Mohammad ; Plattner, Florian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-ec873cfa221104548178bc9aaa7c72d0700b20ab66fd85ef7e92993cfee8c1b03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Algorithms</topic><topic>Checklist</topic><topic>Female</topic><topic>Hip Dislocation, Congenital - diagnostic imaging</topic><topic>Hip Joint - abnormalities</topic><topic>Hip Joint - diagnostic imaging</topic><topic>Humans</topic><topic>Image Enhancement - methods</topic><topic>Infant</topic><topic>Infant, Newborn</topic><topic>Male</topic><topic>Patient Positioning - methods</topic><topic>Ultrasonography - methods</topic><toplevel>online_resources</toplevel><creatorcontrib>Graf, Reinhard</creatorcontrib><creatorcontrib>Mohajer, Mohammad</creatorcontrib><creatorcontrib>Plattner, Florian</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Proquest Nursing & Allied Health Source</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>East Europe, Central Europe Database</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing & Allied Health Premium</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Medical ultrasonography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Graf, Reinhard</au><au>Mohajer, Mohammad</au><au>Plattner, Florian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hip sonography update. Quality-management, catastrophes - tips and tricks</atitle><jtitle>Medical ultrasonography</jtitle><addtitle>Med Ultrason</addtitle><date>2013-12-01</date><risdate>2013</risdate><volume>15</volume><issue>4</issue><spage>299</spage><epage>303</epage><pages>299-303</pages><issn>1844-4172</issn><eissn>2066-8643</eissn><abstract>Hip sonography is today considered to be the diagnostic standard tool for developmental dysplasia of the hip (DDH) diagnosis. In Germany special commissions control the quality of the sonograms according to checklists to keep the standard high and to avoid over- and under - treatment. This paper lists tips and tricks to avoid typical mistakes according to these results.
In 8 German countries the quality of sonograms used to diagnose DDH was checked according to special checklists. An additional 250 medical doctors (pediatricians, radiologists, orthopaedic surgeons) were asked to classify 4 sonograms by measuring and typing. From the same group the projection (standing left, standing right, horizontal-cranial left, horizontal-cranial right) was checked according to the correct diagnosis in the shortest time.
In 1.6 % - 43.7% the licence for hip sonography was withdrawn by the German commission. The best projection with the lowest rate of wrong interpretation was the "standing right"-projection. Most of the mistakes were made because of a wrong anatomical identification and usability check.
Hip sonography must be trained by authorized teachers. The quality of the sonograms must be controlled according to checklists. The bedside teaching without control leads to a systematic teaching of mistakes and finally catastrophes.</abstract><cop>Romania</cop><pub>Romanian Society of Ultrasonography in Medicine and Biology</pub><pmid>24286094</pmid><doi>10.11152/mu.2013.2066.154.rg2</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1844-4172 |
ispartof | Medical ultrasonography, 2013-12, Vol.15 (4), p.299-303 |
issn | 1844-4172 2066-8643 |
language | eng |
recordid | cdi_proquest_journals_1464730292 |
source | MEDLINE; EZB-FREE-00999 freely available EZB journals |
subjects | Algorithms Checklist Female Hip Dislocation, Congenital - diagnostic imaging Hip Joint - abnormalities Hip Joint - diagnostic imaging Humans Image Enhancement - methods Infant Infant, Newborn Male Patient Positioning - methods Ultrasonography - methods |
title | Hip sonography update. Quality-management, catastrophes - tips and tricks |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A08%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hip%20sonography%20update.%20Quality-management,%20catastrophes%20-%20tips%20and%20tricks&rft.jtitle=Medical%20ultrasonography&rft.au=Graf,%20Reinhard&rft.date=2013-12-01&rft.volume=15&rft.issue=4&rft.spage=299&rft.epage=303&rft.pages=299-303&rft.issn=1844-4172&rft.eissn=2066-8643&rft_id=info:doi/10.11152/mu.2013.2066.154.rg2&rft_dat=%3Cproquest_cross%3E3144875871%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1464730292&rft_id=info:pmid/24286094&rfr_iscdi=true |