Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power
This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector...
Gespeichert in:
Veröffentlicht in: | Journal of the Mass Spectrometry Society of Japan 1962/06/30, Vol.10(20), pp.6-12 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 12 |
---|---|
container_issue | 20 |
container_start_page | 6 |
container_title | Journal of the Mass Spectrometry Society of Japan |
container_volume | 10 |
creator | MORITO, NOZOMU OMURA, ITIRO NODA, TAMOTU |
description | This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method. |
doi_str_mv | 10.5702/massspec1953.10.6 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1446897350</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3112142911</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1920-99acbc7e914ba49cd07923c324e58f262834bd94284f3cd23a306a5f791ee63c3</originalsourceid><addsrcrecordid>eNplkE1LAzEQhoMoWKs_wNuCFz1szdcmm2Mp1hZaFK3nJc3O1i37ZZKt-O9NaSmCl5nh5X3eGQahW4JHicT0sdbOuQ4MUQkbBVGcoQFJUxxzSpPzMDOO4xQreYmunNtizKmQcoBWy77yZVdBnJeBt65sm2gZwqL3kOZtW4MHez9_GHedttr3LtJNHs3rzrY7qKHxUdlEb-Daalc2m-i1_QZ7jS4KXTm4OfYh-pg-rSazePHyPJ-MF3E4k-JYKW3WRoIifK25MjmWijLDKIckLaigKePrXHGa8oKZnDLNsNBJIRUBEME4RHeH3HDMVw_OZ9u2t01YmRHORaokS3BwkYPL2NY5C0XW2bLW9icjONs_L_v7vL0oAjM7MFvn9QZOhLa-NBX8Iyg-VnGymE9tM2jYL7Wufvg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1446897350</pqid></control><display><type>article</type><title>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</title><source>J-STAGE Free</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Free Full-Text Journals in Chemistry</source><creator>MORITO, NOZOMU ; OMURA, ITIRO ; NODA, TAMOTU</creator><creatorcontrib>MORITO, NOZOMU ; OMURA, ITIRO ; NODA, TAMOTU</creatorcontrib><description>This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method.</description><identifier>ISSN: 1340-8097</identifier><identifier>EISSN: 1880-4225</identifier><identifier>EISSN: 1884-3271</identifier><identifier>DOI: 10.5702/massspec1953.10.6</identifier><language>eng</language><publisher>Tokyo: The Mass Spectrometry Society of Japan</publisher><ispartof>Journal of the Mass Spectrometry Society of Japan, 1962/06/30, Vol.10(20), pp.6-12</ispartof><rights>The Mass Spectrometry Society of Japan</rights><rights>Copyright Japan Science and Technology Agency 1962</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids></links><search><creatorcontrib>MORITO, NOZOMU</creatorcontrib><creatorcontrib>OMURA, ITIRO</creatorcontrib><creatorcontrib>NODA, TAMOTU</creatorcontrib><title>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</title><title>Journal of the Mass Spectrometry Society of Japan</title><addtitle>J. Mass Spectrom. Soc. Jpn.</addtitle><description>This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method.</description><issn>1340-8097</issn><issn>1880-4225</issn><issn>1884-3271</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1962</creationdate><recordtype>article</recordtype><recordid>eNplkE1LAzEQhoMoWKs_wNuCFz1szdcmm2Mp1hZaFK3nJc3O1i37ZZKt-O9NaSmCl5nh5X3eGQahW4JHicT0sdbOuQ4MUQkbBVGcoQFJUxxzSpPzMDOO4xQreYmunNtizKmQcoBWy77yZVdBnJeBt65sm2gZwqL3kOZtW4MHez9_GHedttr3LtJNHs3rzrY7qKHxUdlEb-Daalc2m-i1_QZ7jS4KXTm4OfYh-pg-rSazePHyPJ-MF3E4k-JYKW3WRoIifK25MjmWijLDKIckLaigKePrXHGa8oKZnDLNsNBJIRUBEME4RHeH3HDMVw_OZ9u2t01YmRHORaokS3BwkYPL2NY5C0XW2bLW9icjONs_L_v7vL0oAjM7MFvn9QZOhLa-NBX8Iyg-VnGymE9tM2jYL7Wufvg</recordid><startdate>19620101</startdate><enddate>19620101</enddate><creator>MORITO, NOZOMU</creator><creator>OMURA, ITIRO</creator><creator>NODA, TAMOTU</creator><general>The Mass Spectrometry Society of Japan</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19620101</creationdate><title>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</title><author>MORITO, NOZOMU ; OMURA, ITIRO ; NODA, TAMOTU</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1920-99acbc7e914ba49cd07923c324e58f262834bd94284f3cd23a306a5f791ee63c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1962</creationdate><toplevel>online_resources</toplevel><creatorcontrib>MORITO, NOZOMU</creatorcontrib><creatorcontrib>OMURA, ITIRO</creatorcontrib><creatorcontrib>NODA, TAMOTU</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of the Mass Spectrometry Society of Japan</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MORITO, NOZOMU</au><au>OMURA, ITIRO</au><au>NODA, TAMOTU</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</atitle><jtitle>Journal of the Mass Spectrometry Society of Japan</jtitle><addtitle>J. Mass Spectrom. Soc. Jpn.</addtitle><date>1962-01-01</date><risdate>1962</risdate><volume>10</volume><issue>20</issue><spage>6</spage><epage>12</epage><pages>6-12</pages><issn>1340-8097</issn><eissn>1880-4225</eissn><eissn>1884-3271</eissn><abstract>This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method.</abstract><cop>Tokyo</cop><pub>The Mass Spectrometry Society of Japan</pub><doi>10.5702/massspec1953.10.6</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1340-8097 |
ispartof | Journal of the Mass Spectrometry Society of Japan, 1962/06/30, Vol.10(20), pp.6-12 |
issn | 1340-8097 1880-4225 1884-3271 |
language | eng |
recordid | cdi_proquest_journals_1446897350 |
source | J-STAGE Free; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Free Full-Text Journals in Chemistry |
title | Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T08%3A32%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multiple-dispersion%20Mass%20Spectrometer(I)Apparatus%20and%20Improvement%20in%20Resolving%20Power&rft.jtitle=Journal%20of%20the%20Mass%20Spectrometry%20Society%20of%20Japan&rft.au=MORITO,%20NOZOMU&rft.date=1962-01-01&rft.volume=10&rft.issue=20&rft.spage=6&rft.epage=12&rft.pages=6-12&rft.issn=1340-8097&rft.eissn=1880-4225&rft_id=info:doi/10.5702/massspec1953.10.6&rft_dat=%3Cproquest_cross%3E3112142911%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1446897350&rft_id=info:pmid/&rfr_iscdi=true |