Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power

This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Mass Spectrometry Society of Japan 1962/06/30, Vol.10(20), pp.6-12
Hauptverfasser: MORITO, NOZOMU, OMURA, ITIRO, NODA, TAMOTU
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 12
container_issue 20
container_start_page 6
container_title Journal of the Mass Spectrometry Society of Japan
container_volume 10
creator MORITO, NOZOMU
OMURA, ITIRO
NODA, TAMOTU
description This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method.
doi_str_mv 10.5702/massspec1953.10.6
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1446897350</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3112142911</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1920-99acbc7e914ba49cd07923c324e58f262834bd94284f3cd23a306a5f791ee63c3</originalsourceid><addsrcrecordid>eNplkE1LAzEQhoMoWKs_wNuCFz1szdcmm2Mp1hZaFK3nJc3O1i37ZZKt-O9NaSmCl5nh5X3eGQahW4JHicT0sdbOuQ4MUQkbBVGcoQFJUxxzSpPzMDOO4xQreYmunNtizKmQcoBWy77yZVdBnJeBt65sm2gZwqL3kOZtW4MHez9_GHedttr3LtJNHs3rzrY7qKHxUdlEb-Daalc2m-i1_QZ7jS4KXTm4OfYh-pg-rSazePHyPJ-MF3E4k-JYKW3WRoIifK25MjmWijLDKIckLaigKePrXHGa8oKZnDLNsNBJIRUBEME4RHeH3HDMVw_OZ9u2t01YmRHORaokS3BwkYPL2NY5C0XW2bLW9icjONs_L_v7vL0oAjM7MFvn9QZOhLa-NBX8Iyg-VnGymE9tM2jYL7Wufvg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1446897350</pqid></control><display><type>article</type><title>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</title><source>J-STAGE Free</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Free Full-Text Journals in Chemistry</source><creator>MORITO, NOZOMU ; OMURA, ITIRO ; NODA, TAMOTU</creator><creatorcontrib>MORITO, NOZOMU ; OMURA, ITIRO ; NODA, TAMOTU</creatorcontrib><description>This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method.</description><identifier>ISSN: 1340-8097</identifier><identifier>EISSN: 1880-4225</identifier><identifier>EISSN: 1884-3271</identifier><identifier>DOI: 10.5702/massspec1953.10.6</identifier><language>eng</language><publisher>Tokyo: The Mass Spectrometry Society of Japan</publisher><ispartof>Journal of the Mass Spectrometry Society of Japan, 1962/06/30, Vol.10(20), pp.6-12</ispartof><rights>The Mass Spectrometry Society of Japan</rights><rights>Copyright Japan Science and Technology Agency 1962</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids></links><search><creatorcontrib>MORITO, NOZOMU</creatorcontrib><creatorcontrib>OMURA, ITIRO</creatorcontrib><creatorcontrib>NODA, TAMOTU</creatorcontrib><title>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</title><title>Journal of the Mass Spectrometry Society of Japan</title><addtitle>J. Mass Spectrom. Soc. Jpn.</addtitle><description>This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method.</description><issn>1340-8097</issn><issn>1880-4225</issn><issn>1884-3271</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1962</creationdate><recordtype>article</recordtype><recordid>eNplkE1LAzEQhoMoWKs_wNuCFz1szdcmm2Mp1hZaFK3nJc3O1i37ZZKt-O9NaSmCl5nh5X3eGQahW4JHicT0sdbOuQ4MUQkbBVGcoQFJUxxzSpPzMDOO4xQreYmunNtizKmQcoBWy77yZVdBnJeBt65sm2gZwqL3kOZtW4MHez9_GHedttr3LtJNHs3rzrY7qKHxUdlEb-Daalc2m-i1_QZ7jS4KXTm4OfYh-pg-rSazePHyPJ-MF3E4k-JYKW3WRoIifK25MjmWijLDKIckLaigKePrXHGa8oKZnDLNsNBJIRUBEME4RHeH3HDMVw_OZ9u2t01YmRHORaokS3BwkYPL2NY5C0XW2bLW9icjONs_L_v7vL0oAjM7MFvn9QZOhLa-NBX8Iyg-VnGymE9tM2jYL7Wufvg</recordid><startdate>19620101</startdate><enddate>19620101</enddate><creator>MORITO, NOZOMU</creator><creator>OMURA, ITIRO</creator><creator>NODA, TAMOTU</creator><general>The Mass Spectrometry Society of Japan</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19620101</creationdate><title>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</title><author>MORITO, NOZOMU ; OMURA, ITIRO ; NODA, TAMOTU</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1920-99acbc7e914ba49cd07923c324e58f262834bd94284f3cd23a306a5f791ee63c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1962</creationdate><toplevel>online_resources</toplevel><creatorcontrib>MORITO, NOZOMU</creatorcontrib><creatorcontrib>OMURA, ITIRO</creatorcontrib><creatorcontrib>NODA, TAMOTU</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of the Mass Spectrometry Society of Japan</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MORITO, NOZOMU</au><au>OMURA, ITIRO</au><au>NODA, TAMOTU</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power</atitle><jtitle>Journal of the Mass Spectrometry Society of Japan</jtitle><addtitle>J. Mass Spectrom. Soc. Jpn.</addtitle><date>1962-01-01</date><risdate>1962</risdate><volume>10</volume><issue>20</issue><spage>6</spage><epage>12</epage><pages>6-12</pages><issn>1340-8097</issn><eissn>1880-4225</eissn><eissn>1884-3271</eissn><abstract>This paper describes the characteristics of a multiple-dispersion mass spectrometer. In the simplest case(i. e. double dispersion), ion beam from the ion source is dispersed in magnetic field, let to the ion mirror and driven back to magnetic field, dispersed again, and received by the ion collector.Resolving power is approximately doubled by the double dispersion method.</abstract><cop>Tokyo</cop><pub>The Mass Spectrometry Society of Japan</pub><doi>10.5702/massspec1953.10.6</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1340-8097
ispartof Journal of the Mass Spectrometry Society of Japan, 1962/06/30, Vol.10(20), pp.6-12
issn 1340-8097
1880-4225
1884-3271
language eng
recordid cdi_proquest_journals_1446897350
source J-STAGE Free; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Free Full-Text Journals in Chemistry
title Multiple-dispersion Mass Spectrometer(I)Apparatus and Improvement in Resolving Power
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T08%3A32%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multiple-dispersion%20Mass%20Spectrometer(I)Apparatus%20and%20Improvement%20in%20Resolving%20Power&rft.jtitle=Journal%20of%20the%20Mass%20Spectrometry%20Society%20of%20Japan&rft.au=MORITO,%20NOZOMU&rft.date=1962-01-01&rft.volume=10&rft.issue=20&rft.spage=6&rft.epage=12&rft.pages=6-12&rft.issn=1340-8097&rft.eissn=1880-4225&rft_id=info:doi/10.5702/massspec1953.10.6&rft_dat=%3Cproquest_cross%3E3112142911%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1446897350&rft_id=info:pmid/&rfr_iscdi=true