Velocity Modulation Type Mass Spectrograph

A non-magnetic velocity modulation type mass spectrograph is proposed, in which the bunching effect of the velocity-modulated ion beams is applied as R.R. Wilson had published in his report on the Isotron. While the Isotron handles a bunch of an isotope formed at a definite position in space, in the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Mass Spectrometry Society of Japan 1959/03/31, Vol.1959(12), pp.45-49
Hauptverfasser: Ezoe, Hirohiko, Hayashi, Tomonao
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 49
container_issue 12
container_start_page 45
container_title Journal of the Mass Spectrometry Society of Japan
container_volume 1959
creator Ezoe, Hirohiko
Hayashi, Tomonao
description A non-magnetic velocity modulation type mass spectrograph is proposed, in which the bunching effect of the velocity-modulated ion beams is applied as R.R. Wilson had published in his report on the Isotron. While the Isotron handles a bunch of an isotope formed at a definite position in space, in the present paper the problems on the recording of the mass spectrum consisting of the spatially distributed bunches are discussed. The neces sary applied voltages, frequencies, and geometrical. dimensions for practical uses are also calculated.
doi_str_mv 10.5702/massspec1953.1959.45
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1446896326</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3112133351</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2465-322dcac6a527cfab2c60c2189d9027ce38c9661b461c7f4d2efd3d5b33315c1c3</originalsourceid><addsrcrecordid>eNptkM1LAzEQxYMoWKv_gYcFb8LWZPKxm6MUv6DFg9VrSGez7ZZtsya7h_73plSKBy_zhuH93sAj5JbRiSwoPGxtjLFzyLTkkzT0RMgzMmJlSXMBIM_TzgXNS6qLS3IV44ZSAaooRuT-y7Uem36fzX01tLZv_C5b7DuXzVNo9pFS--BXwXbra3JR2za6m18dk8_np8X0NZ-9v7xNH2c5glAy5wAVWlRWQoG1XQIqisBKXWmaLo6XqJViS6EYFrWowNUVr-SSc84kMuRjcnfM7YL_HlzszcYPYZdeGiaEKrXioJJLHF0YfIzB1aYLzdaGvWHUHFoxf1sxh1aMkAmbH7FN7O3KnSAb-gZb9w_E4KRCnny4tsG4Hf8Bdu9x_w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1446896326</pqid></control><display><type>article</type><title>Velocity Modulation Type Mass Spectrograph</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Free Full-Text Journals in Chemistry</source><creator>Ezoe, Hirohiko ; Hayashi, Tomonao</creator><creatorcontrib>Ezoe, Hirohiko ; Hayashi, Tomonao</creatorcontrib><description>A non-magnetic velocity modulation type mass spectrograph is proposed, in which the bunching effect of the velocity-modulated ion beams is applied as R.R. Wilson had published in his report on the Isotron. While the Isotron handles a bunch of an isotope formed at a definite position in space, in the present paper the problems on the recording of the mass spectrum consisting of the spatially distributed bunches are discussed. The neces sary applied voltages, frequencies, and geometrical. dimensions for practical uses are also calculated.</description><identifier>ISSN: 1340-8097</identifier><identifier>EISSN: 1880-4225</identifier><identifier>EISSN: 1884-3271</identifier><identifier>DOI: 10.5702/massspec1953.1959.45</identifier><language>eng</language><publisher>Tokyo: The Mass Spectrometry Society of Japan</publisher><ispartof>Journal of the Mass Spectrometry Society of Japan, 1959/03/31, Vol.1959(12), pp.45-49</ispartof><rights>The Mass Spectrometry Society of Japan</rights><rights>Copyright Japan Science and Technology Agency 1959</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1876,27903,27904</link.rule.ids></links><search><creatorcontrib>Ezoe, Hirohiko</creatorcontrib><creatorcontrib>Hayashi, Tomonao</creatorcontrib><title>Velocity Modulation Type Mass Spectrograph</title><title>Journal of the Mass Spectrometry Society of Japan</title><addtitle>J. Mass Spectrom. Soc. Jpn.</addtitle><description>A non-magnetic velocity modulation type mass spectrograph is proposed, in which the bunching effect of the velocity-modulated ion beams is applied as R.R. Wilson had published in his report on the Isotron. While the Isotron handles a bunch of an isotope formed at a definite position in space, in the present paper the problems on the recording of the mass spectrum consisting of the spatially distributed bunches are discussed. The neces sary applied voltages, frequencies, and geometrical. dimensions for practical uses are also calculated.</description><issn>1340-8097</issn><issn>1880-4225</issn><issn>1884-3271</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1959</creationdate><recordtype>article</recordtype><recordid>eNptkM1LAzEQxYMoWKv_gYcFb8LWZPKxm6MUv6DFg9VrSGez7ZZtsya7h_73plSKBy_zhuH93sAj5JbRiSwoPGxtjLFzyLTkkzT0RMgzMmJlSXMBIM_TzgXNS6qLS3IV44ZSAaooRuT-y7Uem36fzX01tLZv_C5b7DuXzVNo9pFS--BXwXbra3JR2za6m18dk8_np8X0NZ-9v7xNH2c5glAy5wAVWlRWQoG1XQIqisBKXWmaLo6XqJViS6EYFrWowNUVr-SSc84kMuRjcnfM7YL_HlzszcYPYZdeGiaEKrXioJJLHF0YfIzB1aYLzdaGvWHUHFoxf1sxh1aMkAmbH7FN7O3KnSAb-gZb9w_E4KRCnny4tsG4Hf8Bdu9x_w</recordid><startdate>19590101</startdate><enddate>19590101</enddate><creator>Ezoe, Hirohiko</creator><creator>Hayashi, Tomonao</creator><general>The Mass Spectrometry Society of Japan</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19590101</creationdate><title>Velocity Modulation Type Mass Spectrograph</title><author>Ezoe, Hirohiko ; Hayashi, Tomonao</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2465-322dcac6a527cfab2c60c2189d9027ce38c9661b461c7f4d2efd3d5b33315c1c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1959</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Ezoe, Hirohiko</creatorcontrib><creatorcontrib>Hayashi, Tomonao</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of the Mass Spectrometry Society of Japan</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ezoe, Hirohiko</au><au>Hayashi, Tomonao</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Velocity Modulation Type Mass Spectrograph</atitle><jtitle>Journal of the Mass Spectrometry Society of Japan</jtitle><addtitle>J. Mass Spectrom. Soc. Jpn.</addtitle><date>1959-01-01</date><risdate>1959</risdate><volume>1959</volume><issue>12</issue><spage>45</spage><epage>49</epage><pages>45-49</pages><issn>1340-8097</issn><eissn>1880-4225</eissn><eissn>1884-3271</eissn><abstract>A non-magnetic velocity modulation type mass spectrograph is proposed, in which the bunching effect of the velocity-modulated ion beams is applied as R.R. Wilson had published in his report on the Isotron. While the Isotron handles a bunch of an isotope formed at a definite position in space, in the present paper the problems on the recording of the mass spectrum consisting of the spatially distributed bunches are discussed. The neces sary applied voltages, frequencies, and geometrical. dimensions for practical uses are also calculated.</abstract><cop>Tokyo</cop><pub>The Mass Spectrometry Society of Japan</pub><doi>10.5702/massspec1953.1959.45</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1340-8097
ispartof Journal of the Mass Spectrometry Society of Japan, 1959/03/31, Vol.1959(12), pp.45-49
issn 1340-8097
1880-4225
1884-3271
language eng
recordid cdi_proquest_journals_1446896326
source J-STAGE Free; EZB-FREE-00999 freely available EZB journals; Free Full-Text Journals in Chemistry
title Velocity Modulation Type Mass Spectrograph
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T10%3A43%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Velocity%20Modulation%20Type%20Mass%20Spectrograph&rft.jtitle=Journal%20of%20the%20Mass%20Spectrometry%20Society%20of%20Japan&rft.au=Ezoe,%20Hirohiko&rft.date=1959-01-01&rft.volume=1959&rft.issue=12&rft.spage=45&rft.epage=49&rft.pages=45-49&rft.issn=1340-8097&rft.eissn=1880-4225&rft_id=info:doi/10.5702/massspec1953.1959.45&rft_dat=%3Cproquest_cross%3E3112133351%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1446896326&rft_id=info:pmid/&rfr_iscdi=true