Influence of Impeller Design on Hemolysis of an Axial Blood Pump
Compared to centrifugal blood pumps, the high rotating speed of axial blood pumps lead to blood damage more easily. In order to improve blood compatibility of the axial blood pump developed by the authors, traditional method and three-dimensional streamlined method are used for axial impeller design...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2012-01, Vol.140, p.162-166 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 166 |
---|---|
container_issue | |
container_start_page | 162 |
container_title | Applied Mechanics and Materials |
container_volume | 140 |
creator | He, Wei Xing Li, Tian Bo Wang, Fang Qun Liu, Lei Ji, Jing Hua Wu, Wen Jue Zhao, Wen Xiang Wu, Qin Lin Qian, Kun Xi |
description | Compared to centrifugal blood pumps, the high rotating speed of axial blood pumps lead to blood damage more easily. In order to improve blood compatibility of the axial blood pump developed by the authors, traditional method and three-dimensional streamlined method are used for axial impeller design, and rapid prototyping with ABS organic materials are adopted. Finally, hydraulic experiments and hemolysis tests have been conducted. The results reveal that the impeller design and the design parameters (diameter and length) affect the hydraulic performance and hemolysis of the axial pump obviously. The hemolysis index in axial flow impeller pump using traditional method is 0.12, while the minimum value of hemolysis index in the streamlined axial blood pump is 0.06, below the permitted hemolysis value of 0.1. |
doi_str_mv | 10.4028/www.scientific.net/AMM.140.162 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1443263604</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3103249881</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-cd520f460c6e67d666c19f79e1325278b2bc8add815546860910ac205c4c926c3</originalsourceid><addsrcrecordid>eNqNkEtLw0AYRQcfoNb-h4DgLum88mVmI6310UKLLnQ9pJOJpiQzNZNQ---dWkGXru7iXs6Fg9A1wQnHVIy2223idWVsV5WVTqzpRpPlMiEcJwToETonADTOuKDHaCgzwTDLREpBypPvDseSMThDF96vMQZOuDhH47kt695YbSJXRvNmY-ratNGd8dWbjZyNZqZx9c5Xft_nNpp8Vnkd3dbOFdFz32wu0WmZ194Mf3KAXh_uX6azePH0OJ9OFrFmKXSxLlKKSw5Yg4GsAABNZJlJQxhNaSZWdKVFXhSCpCkHAVgSnGuKU821pKDZAF0duJvWffTGd2rt-taGS0U4ZxQYYB5WN4eVbp33rSnVpq2avN0pgtXeogoW1a9FFSyqYDEwsAoWA2B8AHRtbn1n9Pufn_8hvgCiHX8s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1443263604</pqid></control><display><type>article</type><title>Influence of Impeller Design on Hemolysis of an Axial Blood Pump</title><source>Scientific.net Journals</source><creator>He, Wei Xing ; Li, Tian Bo ; Wang, Fang Qun ; Liu, Lei ; Ji, Jing Hua ; Wu, Wen Jue ; Zhao, Wen Xiang ; Wu, Qin Lin ; Qian, Kun Xi</creator><creatorcontrib>He, Wei Xing ; Li, Tian Bo ; Wang, Fang Qun ; Liu, Lei ; Ji, Jing Hua ; Wu, Wen Jue ; Zhao, Wen Xiang ; Wu, Qin Lin ; Qian, Kun Xi</creatorcontrib><description>Compared to centrifugal blood pumps, the high rotating speed of axial blood pumps lead to blood damage more easily. In order to improve blood compatibility of the axial blood pump developed by the authors, traditional method and three-dimensional streamlined method are used for axial impeller design, and rapid prototyping with ABS organic materials are adopted. Finally, hydraulic experiments and hemolysis tests have been conducted. The results reveal that the impeller design and the design parameters (diameter and length) affect the hydraulic performance and hemolysis of the axial pump obviously. The hemolysis index in axial flow impeller pump using traditional method is 0.12, while the minimum value of hemolysis index in the streamlined axial blood pump is 0.06, below the permitted hemolysis value of 0.1.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 9783037852699</identifier><identifier>ISBN: 3037852690</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.140.162</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><ispartof>Applied Mechanics and Materials, 2012-01, Vol.140, p.162-166</ispartof><rights>2012 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Nov 2011</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-cd520f460c6e67d666c19f79e1325278b2bc8add815546860910ac205c4c926c3</citedby><cites>FETCH-LOGICAL-c356t-cd520f460c6e67d666c19f79e1325278b2bc8add815546860910ac205c4c926c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/1481?width=600</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>He, Wei Xing</creatorcontrib><creatorcontrib>Li, Tian Bo</creatorcontrib><creatorcontrib>Wang, Fang Qun</creatorcontrib><creatorcontrib>Liu, Lei</creatorcontrib><creatorcontrib>Ji, Jing Hua</creatorcontrib><creatorcontrib>Wu, Wen Jue</creatorcontrib><creatorcontrib>Zhao, Wen Xiang</creatorcontrib><creatorcontrib>Wu, Qin Lin</creatorcontrib><creatorcontrib>Qian, Kun Xi</creatorcontrib><title>Influence of Impeller Design on Hemolysis of an Axial Blood Pump</title><title>Applied Mechanics and Materials</title><description>Compared to centrifugal blood pumps, the high rotating speed of axial blood pumps lead to blood damage more easily. In order to improve blood compatibility of the axial blood pump developed by the authors, traditional method and three-dimensional streamlined method are used for axial impeller design, and rapid prototyping with ABS organic materials are adopted. Finally, hydraulic experiments and hemolysis tests have been conducted. The results reveal that the impeller design and the design parameters (diameter and length) affect the hydraulic performance and hemolysis of the axial pump obviously. The hemolysis index in axial flow impeller pump using traditional method is 0.12, while the minimum value of hemolysis index in the streamlined axial blood pump is 0.06, below the permitted hemolysis value of 0.1.</description><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>9783037852699</isbn><isbn>3037852690</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNkEtLw0AYRQcfoNb-h4DgLum88mVmI6310UKLLnQ9pJOJpiQzNZNQ---dWkGXru7iXs6Fg9A1wQnHVIy2223idWVsV5WVTqzpRpPlMiEcJwToETonADTOuKDHaCgzwTDLREpBypPvDseSMThDF96vMQZOuDhH47kt695YbSJXRvNmY-ratNGd8dWbjZyNZqZx9c5Xft_nNpp8Vnkd3dbOFdFz32wu0WmZ194Mf3KAXh_uX6azePH0OJ9OFrFmKXSxLlKKSw5Yg4GsAABNZJlJQxhNaSZWdKVFXhSCpCkHAVgSnGuKU821pKDZAF0duJvWffTGd2rt-taGS0U4ZxQYYB5WN4eVbp33rSnVpq2avN0pgtXeogoW1a9FFSyqYDEwsAoWA2B8AHRtbn1n9Pufn_8hvgCiHX8s</recordid><startdate>20120101</startdate><enddate>20120101</enddate><creator>He, Wei Xing</creator><creator>Li, Tian Bo</creator><creator>Wang, Fang Qun</creator><creator>Liu, Lei</creator><creator>Ji, Jing Hua</creator><creator>Wu, Wen Jue</creator><creator>Zhao, Wen Xiang</creator><creator>Wu, Qin Lin</creator><creator>Qian, Kun Xi</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20120101</creationdate><title>Influence of Impeller Design on Hemolysis of an Axial Blood Pump</title><author>He, Wei Xing ; Li, Tian Bo ; Wang, Fang Qun ; Liu, Lei ; Ji, Jing Hua ; Wu, Wen Jue ; Zhao, Wen Xiang ; Wu, Qin Lin ; Qian, Kun Xi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-cd520f460c6e67d666c19f79e1325278b2bc8add815546860910ac205c4c926c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>He, Wei Xing</creatorcontrib><creatorcontrib>Li, Tian Bo</creatorcontrib><creatorcontrib>Wang, Fang Qun</creatorcontrib><creatorcontrib>Liu, Lei</creatorcontrib><creatorcontrib>Ji, Jing Hua</creatorcontrib><creatorcontrib>Wu, Wen Jue</creatorcontrib><creatorcontrib>Zhao, Wen Xiang</creatorcontrib><creatorcontrib>Wu, Qin Lin</creatorcontrib><creatorcontrib>Qian, Kun Xi</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Applied Mechanics and Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>He, Wei Xing</au><au>Li, Tian Bo</au><au>Wang, Fang Qun</au><au>Liu, Lei</au><au>Ji, Jing Hua</au><au>Wu, Wen Jue</au><au>Zhao, Wen Xiang</au><au>Wu, Qin Lin</au><au>Qian, Kun Xi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of Impeller Design on Hemolysis of an Axial Blood Pump</atitle><jtitle>Applied Mechanics and Materials</jtitle><date>2012-01-01</date><risdate>2012</risdate><volume>140</volume><spage>162</spage><epage>166</epage><pages>162-166</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>9783037852699</isbn><isbn>3037852690</isbn><abstract>Compared to centrifugal blood pumps, the high rotating speed of axial blood pumps lead to blood damage more easily. In order to improve blood compatibility of the axial blood pump developed by the authors, traditional method and three-dimensional streamlined method are used for axial impeller design, and rapid prototyping with ABS organic materials are adopted. Finally, hydraulic experiments and hemolysis tests have been conducted. The results reveal that the impeller design and the design parameters (diameter and length) affect the hydraulic performance and hemolysis of the axial pump obviously. The hemolysis index in axial flow impeller pump using traditional method is 0.12, while the minimum value of hemolysis index in the streamlined axial blood pump is 0.06, below the permitted hemolysis value of 0.1.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.140.162</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1660-9336 |
ispartof | Applied Mechanics and Materials, 2012-01, Vol.140, p.162-166 |
issn | 1660-9336 1662-7482 1662-7482 |
language | eng |
recordid | cdi_proquest_journals_1443263604 |
source | Scientific.net Journals |
title | Influence of Impeller Design on Hemolysis of an Axial Blood Pump |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T10%3A41%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20Impeller%20Design%20on%20Hemolysis%20of%20an%20Axial%20Blood%20Pump&rft.jtitle=Applied%20Mechanics%20and%20Materials&rft.au=He,%20Wei%20Xing&rft.date=2012-01-01&rft.volume=140&rft.spage=162&rft.epage=166&rft.pages=162-166&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=9783037852699&rft.isbn_list=3037852690&rft_id=info:doi/10.4028/www.scientific.net/AMM.140.162&rft_dat=%3Cproquest_cross%3E3103249881%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1443263604&rft_id=info:pmid/&rfr_iscdi=true |