Research on Two-Step Damage Detection Method for Complex Gird Truss Structure under Wind Load

Considering characteristics of gird truss structure, the suitable two-step damage detection method for these structures is proposed in the paper. The acceleration power spectral density sensibility of structural nodes is obtained by analyzing their acceleration power spectral density value caused ev...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2013-01, Vol.256-259, p.1131-1138
Hauptverfasser: Wang, Xue Liang, Liu, Hui, Qu, Wei Lian
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1138
container_issue
container_start_page 1131
container_title Applied Mechanics and Materials
container_volume 256-259
creator Wang, Xue Liang
Liu, Hui
Qu, Wei Lian
description Considering characteristics of gird truss structure, the suitable two-step damage detection method for these structures is proposed in the paper. The acceleration power spectral density sensibility of structural nodes is obtained by analyzing their acceleration power spectral density value caused every damaged structural bar. According to sensibility value, the range of influence of damaged structural bar is determined, then structural sub regions are divided and accelerators are distributed. The first step damage detection methods is identifying damaged bar occurrence region, it is extracting damage index to identify the damage occurrence region based on changes of acceleration response power spectral density of structure damaged after and before. The second step damage detection methods is located damaged bar in the region, it is completed by finding the damaged bar based on the theory of dissipation ratio of modal strain energy damage detection method. At last, taking the gird truss structure as numerical example, it shows the method has the capability to detect the damage of complex gird truss structures successfully.
doi_str_mv 10.4028/www.scientific.net/AMM.256-259.1131
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1442716856</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3102246691</sourcerecordid><originalsourceid>FETCH-LOGICAL-c305t-aa660452d8bfd9f72ebc70f495872fdc538e2dbb997f4a78aa3ff93945820d603</originalsourceid><addsrcrecordid>eNqVkEtLHEEURouYQIz6HwqylG7r_VjK-EhgBkEnuApFTT0yLU7XWFXNxH-f0hF0m8XlLu7H-S4HgFOMeoaIOtvtdn1xQxjrEAfXj6GenS8WPeGiI1z3GFP8CRxiIUgnmSIH4ERLRRGVinPByefXG-o0peIr-FbKA0KCYaYOwe_bUILNbg3TCJe71N3VsIUXdmP_BHgRanB1aJdFqOvkYUwZztJm-xj-wushe7jMUynwrubJ1SkHOI0-ZHg_jB7Ok_XH4Eu0jyWcvO0j8Ovqcjn70c1vrn_Ozuedo4jXztr2HePEq1X0OkoSVk6iyDRXkkTvOFWB-NVKaxmZlcpaGqOmmnFFkBeIHoHve-42p6cplGoe0pTHVmkwY0Riobhoqdk-5XIqJYdotnnY2PxsMDIvnk3zbN49m-bZNM-meW6jzYvnRrncU2q2Y2mC1h_K_oPzD_2qjns</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1442716856</pqid></control><display><type>article</type><title>Research on Two-Step Damage Detection Method for Complex Gird Truss Structure under Wind Load</title><source>Scientific.net Journals</source><creator>Wang, Xue Liang ; Liu, Hui ; Qu, Wei Lian</creator><creatorcontrib>Wang, Xue Liang ; Liu, Hui ; Qu, Wei Lian</creatorcontrib><description>Considering characteristics of gird truss structure, the suitable two-step damage detection method for these structures is proposed in the paper. The acceleration power spectral density sensibility of structural nodes is obtained by analyzing their acceleration power spectral density value caused every damaged structural bar. According to sensibility value, the range of influence of damaged structural bar is determined, then structural sub regions are divided and accelerators are distributed. The first step damage detection methods is identifying damaged bar occurrence region, it is extracting damage index to identify the damage occurrence region based on changes of acceleration response power spectral density of structure damaged after and before. The second step damage detection methods is located damaged bar in the region, it is completed by finding the damaged bar based on the theory of dissipation ratio of modal strain energy damage detection method. At last, taking the gird truss structure as numerical example, it shows the method has the capability to detect the damage of complex gird truss structures successfully.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 9783037855652</identifier><identifier>ISBN: 3037855657</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.256-259.1131</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><ispartof>Applied Mechanics and Materials, 2013-01, Vol.256-259, p.1131-1138</ispartof><rights>2013 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Dec 2012</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c305t-aa660452d8bfd9f72ebc70f495872fdc538e2dbb997f4a78aa3ff93945820d603</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/2156?width=600</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Wang, Xue Liang</creatorcontrib><creatorcontrib>Liu, Hui</creatorcontrib><creatorcontrib>Qu, Wei Lian</creatorcontrib><title>Research on Two-Step Damage Detection Method for Complex Gird Truss Structure under Wind Load</title><title>Applied Mechanics and Materials</title><description>Considering characteristics of gird truss structure, the suitable two-step damage detection method for these structures is proposed in the paper. The acceleration power spectral density sensibility of structural nodes is obtained by analyzing their acceleration power spectral density value caused every damaged structural bar. According to sensibility value, the range of influence of damaged structural bar is determined, then structural sub regions are divided and accelerators are distributed. The first step damage detection methods is identifying damaged bar occurrence region, it is extracting damage index to identify the damage occurrence region based on changes of acceleration response power spectral density of structure damaged after and before. The second step damage detection methods is located damaged bar in the region, it is completed by finding the damaged bar based on the theory of dissipation ratio of modal strain energy damage detection method. At last, taking the gird truss structure as numerical example, it shows the method has the capability to detect the damage of complex gird truss structures successfully.</description><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>9783037855652</isbn><isbn>3037855657</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqVkEtLHEEURouYQIz6HwqylG7r_VjK-EhgBkEnuApFTT0yLU7XWFXNxH-f0hF0m8XlLu7H-S4HgFOMeoaIOtvtdn1xQxjrEAfXj6GenS8WPeGiI1z3GFP8CRxiIUgnmSIH4ERLRRGVinPByefXG-o0peIr-FbKA0KCYaYOwe_bUILNbg3TCJe71N3VsIUXdmP_BHgRanB1aJdFqOvkYUwZztJm-xj-wushe7jMUynwrubJ1SkHOI0-ZHg_jB7Ok_XH4Eu0jyWcvO0j8Ovqcjn70c1vrn_Ozuedo4jXztr2HePEq1X0OkoSVk6iyDRXkkTvOFWB-NVKaxmZlcpaGqOmmnFFkBeIHoHve-42p6cplGoe0pTHVmkwY0Riobhoqdk-5XIqJYdotnnY2PxsMDIvnk3zbN49m-bZNM-meW6jzYvnRrncU2q2Y2mC1h_K_oPzD_2qjns</recordid><startdate>20130101</startdate><enddate>20130101</enddate><creator>Wang, Xue Liang</creator><creator>Liu, Hui</creator><creator>Qu, Wei Lian</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20130101</creationdate><title>Research on Two-Step Damage Detection Method for Complex Gird Truss Structure under Wind Load</title><author>Wang, Xue Liang ; Liu, Hui ; Qu, Wei Lian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c305t-aa660452d8bfd9f72ebc70f495872fdc538e2dbb997f4a78aa3ff93945820d603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Xue Liang</creatorcontrib><creatorcontrib>Liu, Hui</creatorcontrib><creatorcontrib>Qu, Wei Lian</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Applied Mechanics and Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Xue Liang</au><au>Liu, Hui</au><au>Qu, Wei Lian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Research on Two-Step Damage Detection Method for Complex Gird Truss Structure under Wind Load</atitle><jtitle>Applied Mechanics and Materials</jtitle><date>2013-01-01</date><risdate>2013</risdate><volume>256-259</volume><spage>1131</spage><epage>1138</epage><pages>1131-1138</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>9783037855652</isbn><isbn>3037855657</isbn><abstract>Considering characteristics of gird truss structure, the suitable two-step damage detection method for these structures is proposed in the paper. The acceleration power spectral density sensibility of structural nodes is obtained by analyzing their acceleration power spectral density value caused every damaged structural bar. According to sensibility value, the range of influence of damaged structural bar is determined, then structural sub regions are divided and accelerators are distributed. The first step damage detection methods is identifying damaged bar occurrence region, it is extracting damage index to identify the damage occurrence region based on changes of acceleration response power spectral density of structure damaged after and before. The second step damage detection methods is located damaged bar in the region, it is completed by finding the damaged bar based on the theory of dissipation ratio of modal strain energy damage detection method. At last, taking the gird truss structure as numerical example, it shows the method has the capability to detect the damage of complex gird truss structures successfully.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.256-259.1131</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1660-9336
ispartof Applied Mechanics and Materials, 2013-01, Vol.256-259, p.1131-1138
issn 1660-9336
1662-7482
1662-7482
language eng
recordid cdi_proquest_journals_1442716856
source Scientific.net Journals
title Research on Two-Step Damage Detection Method for Complex Gird Truss Structure under Wind Load
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T17%3A20%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Research%20on%20Two-Step%20Damage%20Detection%20Method%20for%20Complex%20Gird%20Truss%20Structure%20under%20Wind%20Load&rft.jtitle=Applied%20Mechanics%20and%20Materials&rft.au=Wang,%20Xue%20Liang&rft.date=2013-01-01&rft.volume=256-259&rft.spage=1131&rft.epage=1138&rft.pages=1131-1138&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=9783037855652&rft.isbn_list=3037855657&rft_id=info:doi/10.4028/www.scientific.net/AMM.256-259.1131&rft_dat=%3Cproquest_cross%3E3102246691%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1442716856&rft_id=info:pmid/&rfr_iscdi=true