Working Condition Diagnostics System for Electrical Submersible Pump in Geothermal Well

The situation of the global energy is tending to be in short supply, but geotherm is the inexhaustible renewable energy. Extracting reservoir geothermal water from old oil well can achieve economic benefits of oil - heat joint production. Since 2005, Huabei oilfield has been engaging in geothermal c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2013-01, Vol.291-294, p.1993-1998
Hauptverfasser: Wei, Ya Zhen, Chen, Lei, Wu, Guo Dong, Li, Zhen Long, Wang, Feng Qing, Liu, Li Feng, Dong, Jia Shan
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1998
container_issue
container_start_page 1993
container_title Applied Mechanics and Materials
container_volume 291-294
creator Wei, Ya Zhen
Chen, Lei
Wu, Guo Dong
Li, Zhen Long
Wang, Feng Qing
Liu, Li Feng
Dong, Jia Shan
description The situation of the global energy is tending to be in short supply, but geotherm is the inexhaustible renewable energy. Extracting reservoir geothermal water from old oil well can achieve economic benefits of oil - heat joint production. Since 2005, Huabei oilfield has been engaging in geothermal comprehensive utilization research projects and developed the large displacement electrical submersible pumps suitable for high temperature. For the operation management of this equipment, the working condition diagnosis analysis research has been carried out, 16 kinds of current curve template and 73 kinds of pump characteristic curve template have been established using ADO remote data access technology, and the volume efficiency and energy efficiency dynamic control model and chart have been established as well. The production situation analysis using the chart can timely find out the problems existing in the production and puts forward the improvement measures to achieve the purpose of energy saving and consumption reduction.
doi_str_mv 10.4028/www.scientific.net/AMM.291-294.1993
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1442508259</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3101324461</sourcerecordid><originalsourceid>FETCH-LOGICAL-c346t-97f756a9915d95d61c3858b2c345c88635b2b87ee57e61607b1353744009f2f63</originalsourceid><addsrcrecordid>eNqVkM1qGzEYRUWaQtM07yDossxE_z_L4DppISGBJHgpZmSNrWRGciUZ47evXAfSbRYf3-JezoUDwA-MWoaIutztdm223oXiB2_b4Mrl1d1dSzRuiGYt1pqegDMsBGkkU-QTuNBSUUSl4oIyfvovQ42mVHwBX3N-QUgwzNQZWCxievVhBWcxLH3xMcCfvluFmIu3GT7uc3ETHGKC89HZkrztRvi47SeXsu9HBx-20wb6AG9cLGuXphov3Dh-A5-Hbszu4u2fg-fr-dPsV3N7f_N7dnXbWMpEabQcJBed1pgvNV8KbKniqic15VYpQXlPeiWd49IJLJDsMeVUMoaQHsgg6Dn4fuRuUvyzdbmYl7hNoU4azBjhSBGua2t2bNkUc05uMJvkpy7tDUbmYNhUw-bdsKmGTTVsquF6zBwMV8r8SCmpC9WLXf839gHOX2Vki9k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1442508259</pqid></control><display><type>article</type><title>Working Condition Diagnostics System for Electrical Submersible Pump in Geothermal Well</title><source>Scientific.net Journals</source><creator>Wei, Ya Zhen ; Chen, Lei ; Wu, Guo Dong ; Li, Zhen Long ; Wang, Feng Qing ; Liu, Li Feng ; Dong, Jia Shan</creator><creatorcontrib>Wei, Ya Zhen ; Chen, Lei ; Wu, Guo Dong ; Li, Zhen Long ; Wang, Feng Qing ; Liu, Li Feng ; Dong, Jia Shan</creatorcontrib><description>The situation of the global energy is tending to be in short supply, but geotherm is the inexhaustible renewable energy. Extracting reservoir geothermal water from old oil well can achieve economic benefits of oil - heat joint production. Since 2005, Huabei oilfield has been engaging in geothermal comprehensive utilization research projects and developed the large displacement electrical submersible pumps suitable for high temperature. For the operation management of this equipment, the working condition diagnosis analysis research has been carried out, 16 kinds of current curve template and 73 kinds of pump characteristic curve template have been established using ADO remote data access technology, and the volume efficiency and energy efficiency dynamic control model and chart have been established as well. The production situation analysis using the chart can timely find out the problems existing in the production and puts forward the improvement measures to achieve the purpose of energy saving and consumption reduction.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 9783037856345</identifier><identifier>ISBN: 3037856343</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.291-294.1993</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><ispartof>Applied Mechanics and Materials, 2013-01, Vol.291-294, p.1993-1998</ispartof><rights>2013 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Feb 2013</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/2279?width=600</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Wei, Ya Zhen</creatorcontrib><creatorcontrib>Chen, Lei</creatorcontrib><creatorcontrib>Wu, Guo Dong</creatorcontrib><creatorcontrib>Li, Zhen Long</creatorcontrib><creatorcontrib>Wang, Feng Qing</creatorcontrib><creatorcontrib>Liu, Li Feng</creatorcontrib><creatorcontrib>Dong, Jia Shan</creatorcontrib><title>Working Condition Diagnostics System for Electrical Submersible Pump in Geothermal Well</title><title>Applied Mechanics and Materials</title><description>The situation of the global energy is tending to be in short supply, but geotherm is the inexhaustible renewable energy. Extracting reservoir geothermal water from old oil well can achieve economic benefits of oil - heat joint production. Since 2005, Huabei oilfield has been engaging in geothermal comprehensive utilization research projects and developed the large displacement electrical submersible pumps suitable for high temperature. For the operation management of this equipment, the working condition diagnosis analysis research has been carried out, 16 kinds of current curve template and 73 kinds of pump characteristic curve template have been established using ADO remote data access technology, and the volume efficiency and energy efficiency dynamic control model and chart have been established as well. The production situation analysis using the chart can timely find out the problems existing in the production and puts forward the improvement measures to achieve the purpose of energy saving and consumption reduction.</description><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>9783037856345</isbn><isbn>3037856343</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNqVkM1qGzEYRUWaQtM07yDossxE_z_L4DppISGBJHgpZmSNrWRGciUZ47evXAfSbRYf3-JezoUDwA-MWoaIutztdm223oXiB2_b4Mrl1d1dSzRuiGYt1pqegDMsBGkkU-QTuNBSUUSl4oIyfvovQ42mVHwBX3N-QUgwzNQZWCxievVhBWcxLH3xMcCfvluFmIu3GT7uc3ETHGKC89HZkrztRvi47SeXsu9HBx-20wb6AG9cLGuXphov3Dh-A5-Hbszu4u2fg-fr-dPsV3N7f_N7dnXbWMpEabQcJBed1pgvNV8KbKniqic15VYpQXlPeiWd49IJLJDsMeVUMoaQHsgg6Dn4fuRuUvyzdbmYl7hNoU4azBjhSBGua2t2bNkUc05uMJvkpy7tDUbmYNhUw-bdsKmGTTVsquF6zBwMV8r8SCmpC9WLXf839gHOX2Vki9k</recordid><startdate>20130101</startdate><enddate>20130101</enddate><creator>Wei, Ya Zhen</creator><creator>Chen, Lei</creator><creator>Wu, Guo Dong</creator><creator>Li, Zhen Long</creator><creator>Wang, Feng Qing</creator><creator>Liu, Li Feng</creator><creator>Dong, Jia Shan</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20130101</creationdate><title>Working Condition Diagnostics System for Electrical Submersible Pump in Geothermal Well</title><author>Wei, Ya Zhen ; Chen, Lei ; Wu, Guo Dong ; Li, Zhen Long ; Wang, Feng Qing ; Liu, Li Feng ; Dong, Jia Shan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c346t-97f756a9915d95d61c3858b2c345c88635b2b87ee57e61607b1353744009f2f63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wei, Ya Zhen</creatorcontrib><creatorcontrib>Chen, Lei</creatorcontrib><creatorcontrib>Wu, Guo Dong</creatorcontrib><creatorcontrib>Li, Zhen Long</creatorcontrib><creatorcontrib>Wang, Feng Qing</creatorcontrib><creatorcontrib>Liu, Li Feng</creatorcontrib><creatorcontrib>Dong, Jia Shan</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Applied Mechanics and Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wei, Ya Zhen</au><au>Chen, Lei</au><au>Wu, Guo Dong</au><au>Li, Zhen Long</au><au>Wang, Feng Qing</au><au>Liu, Li Feng</au><au>Dong, Jia Shan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Working Condition Diagnostics System for Electrical Submersible Pump in Geothermal Well</atitle><jtitle>Applied Mechanics and Materials</jtitle><date>2013-01-01</date><risdate>2013</risdate><volume>291-294</volume><spage>1993</spage><epage>1998</epage><pages>1993-1998</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>9783037856345</isbn><isbn>3037856343</isbn><abstract>The situation of the global energy is tending to be in short supply, but geotherm is the inexhaustible renewable energy. Extracting reservoir geothermal water from old oil well can achieve economic benefits of oil - heat joint production. Since 2005, Huabei oilfield has been engaging in geothermal comprehensive utilization research projects and developed the large displacement electrical submersible pumps suitable for high temperature. For the operation management of this equipment, the working condition diagnosis analysis research has been carried out, 16 kinds of current curve template and 73 kinds of pump characteristic curve template have been established using ADO remote data access technology, and the volume efficiency and energy efficiency dynamic control model and chart have been established as well. The production situation analysis using the chart can timely find out the problems existing in the production and puts forward the improvement measures to achieve the purpose of energy saving and consumption reduction.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.291-294.1993</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1660-9336
ispartof Applied Mechanics and Materials, 2013-01, Vol.291-294, p.1993-1998
issn 1660-9336
1662-7482
1662-7482
language eng
recordid cdi_proquest_journals_1442508259
source Scientific.net Journals
title Working Condition Diagnostics System for Electrical Submersible Pump in Geothermal Well
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T16%3A30%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Working%20Condition%20Diagnostics%20System%20for%20Electrical%20Submersible%20Pump%20in%20Geothermal%20Well&rft.jtitle=Applied%20Mechanics%20and%20Materials&rft.au=Wei,%20Ya%20Zhen&rft.date=2013-01-01&rft.volume=291-294&rft.spage=1993&rft.epage=1998&rft.pages=1993-1998&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=9783037856345&rft.isbn_list=3037856343&rft_id=info:doi/10.4028/www.scientific.net/AMM.291-294.1993&rft_dat=%3Cproquest_cross%3E3101324461%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1442508259&rft_id=info:pmid/&rfr_iscdi=true