Static Pressure Measurement of High Enthalpy Flowin Arc-Heated Wind Tunnel

NAL has been promoting diagnostic study of the 750kW arc-heated wind tunnel flow to characterize various important flow parameters, such as heat flux and pressure, necessary for determining materials test conditions. In those measurement techniques, static pressure data is one of the most difficult...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES 2002, Vol.50(585), pp.426-426
Hauptverfasser: Matsuzaki, Takashi, Ishida, Kiyomichi, Ito, Takeshi, Kurotaki, Takuji, Watanabe, Yasuo, Fukui, Toshio
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 426
container_issue 585
container_start_page 426
container_title JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES
container_volume 50
creator Matsuzaki, Takashi
Ishida, Kiyomichi
Ito, Takeshi
Kurotaki, Takuji
Watanabe, Yasuo
Fukui, Toshio
description NAL has been promoting diagnostic study of the 750kW arc-heated wind tunnel flow to characterize various important flow parameters, such as heat flux and pressure, necessary for determining materials test conditions. In those measurement techniques, static pressure data is one of the most difficult experimental items to obtain. In this report, design of a static pressure probe and measurement system for the pressure, calibration system and the results, and evaluation of response time of the pressure are presented. The results show that static pressure distributions of the high enthalpy air flow in the NAL/NASDA 750kW arc-heated wind tunnel were obtained with good accuracy using these techniques.
doi_str_mv 10.2322/jjsass.50.426
format Article
fullrecord <record><control><sourceid>proquest_jstag</sourceid><recordid>TN_cdi_proquest_journals_1438000404</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3085960981</sourcerecordid><originalsourceid>FETCH-LOGICAL-j914-624cead26cffdf27976d4e5918c27985b9525e2fefe4040cb49f8bdf6e0e532d3</originalsourceid><addsrcrecordid>eNo9kM1Lw0AQxRdRsNQevS94Tt3vJsdSWlupKFjwuGw2s21Cuqm7CdL_3pWqp8cMv5l58xC6p2TKOGOPTRNNjFNJpoKpKzRigrOMq4JeoxHlQmRKKHKLJjHWJaGCzvLUGKHn9970tcVvAWIcAuAXMD96BN_jzuF1vT_gpe8Ppj2d8artvmqP58FmazA9VPij9hXeDd5De4dunGkjTH51jHar5W6xzravT5vFfJs1BU02mLBgKqasc5Vjs2KmKgGyoLlNRS7LQjIJzIEDQQSxpShcXlZOAQHJWcXH6OGy9hS6zwFir5tuCD5d1FTwnJA0JRK1ulBN7M0e9CnURxPO2oT0bQv6EpeWRMtc_klK7h-wBxM0eP4NkXBo3g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1438000404</pqid></control><display><type>article</type><title>Static Pressure Measurement of High Enthalpy Flowin Arc-Heated Wind Tunnel</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Matsuzaki, Takashi ; Ishida, Kiyomichi ; Ito, Takeshi ; Kurotaki, Takuji ; Watanabe, Yasuo ; Fukui, Toshio</creator><creatorcontrib>Matsuzaki, Takashi ; Ishida, Kiyomichi ; Ito, Takeshi ; Kurotaki, Takuji ; Watanabe, Yasuo ; Fukui, Toshio</creatorcontrib><description>NAL has been promoting diagnostic study of the 750kW arc-heated wind tunnel flow to characterize various important flow parameters, such as heat flux and pressure, necessary for determining materials test conditions. In those measurement techniques, static pressure data is one of the most difficult experimental items to obtain. In this report, design of a static pressure probe and measurement system for the pressure, calibration system and the results, and evaluation of response time of the pressure are presented. The results show that static pressure distributions of the high enthalpy air flow in the NAL/NASDA 750kW arc-heated wind tunnel were obtained with good accuracy using these techniques.</description><identifier>ISSN: 1344-6460</identifier><identifier>EISSN: 2432-3691</identifier><identifier>DOI: 10.2322/jjsass.50.426</identifier><language>eng ; jpn</language><publisher>Tokyo: THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES</publisher><subject>Arc-Heated Wind Tunnel ; High Enthalpy Flow ; Uniform Flow Evaluation</subject><ispartof>JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, 2002, Vol.50(585), pp.426-426</ispartof><rights>2002 The Japan Society for Aeronautical and Space Sciences</rights><rights>Copyright Japan Science and Technology Agency 2002</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Matsuzaki, Takashi</creatorcontrib><creatorcontrib>Ishida, Kiyomichi</creatorcontrib><creatorcontrib>Ito, Takeshi</creatorcontrib><creatorcontrib>Kurotaki, Takuji</creatorcontrib><creatorcontrib>Watanabe, Yasuo</creatorcontrib><creatorcontrib>Fukui, Toshio</creatorcontrib><title>Static Pressure Measurement of High Enthalpy Flowin Arc-Heated Wind Tunnel</title><title>JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES</title><description>NAL has been promoting diagnostic study of the 750kW arc-heated wind tunnel flow to characterize various important flow parameters, such as heat flux and pressure, necessary for determining materials test conditions. In those measurement techniques, static pressure data is one of the most difficult experimental items to obtain. In this report, design of a static pressure probe and measurement system for the pressure, calibration system and the results, and evaluation of response time of the pressure are presented. The results show that static pressure distributions of the high enthalpy air flow in the NAL/NASDA 750kW arc-heated wind tunnel were obtained with good accuracy using these techniques.</description><subject>Arc-Heated Wind Tunnel</subject><subject>High Enthalpy Flow</subject><subject>Uniform Flow Evaluation</subject><issn>1344-6460</issn><issn>2432-3691</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNo9kM1Lw0AQxRdRsNQevS94Tt3vJsdSWlupKFjwuGw2s21Cuqm7CdL_3pWqp8cMv5l58xC6p2TKOGOPTRNNjFNJpoKpKzRigrOMq4JeoxHlQmRKKHKLJjHWJaGCzvLUGKHn9970tcVvAWIcAuAXMD96BN_jzuF1vT_gpe8Ppj2d8artvmqP58FmazA9VPij9hXeDd5De4dunGkjTH51jHar5W6xzravT5vFfJs1BU02mLBgKqasc5Vjs2KmKgGyoLlNRS7LQjIJzIEDQQSxpShcXlZOAQHJWcXH6OGy9hS6zwFir5tuCD5d1FTwnJA0JRK1ulBN7M0e9CnURxPO2oT0bQv6EpeWRMtc_klK7h-wBxM0eP4NkXBo3g</recordid><startdate>2002</startdate><enddate>2002</enddate><creator>Matsuzaki, Takashi</creator><creator>Ishida, Kiyomichi</creator><creator>Ito, Takeshi</creator><creator>Kurotaki, Takuji</creator><creator>Watanabe, Yasuo</creator><creator>Fukui, Toshio</creator><general>THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES</general><general>Japan Science and Technology Agency</general><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>2002</creationdate><title>Static Pressure Measurement of High Enthalpy Flowin Arc-Heated Wind Tunnel</title><author>Matsuzaki, Takashi ; Ishida, Kiyomichi ; Ito, Takeshi ; Kurotaki, Takuji ; Watanabe, Yasuo ; Fukui, Toshio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j914-624cead26cffdf27976d4e5918c27985b9525e2fefe4040cb49f8bdf6e0e532d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2002</creationdate><topic>Arc-Heated Wind Tunnel</topic><topic>High Enthalpy Flow</topic><topic>Uniform Flow Evaluation</topic><toplevel>online_resources</toplevel><creatorcontrib>Matsuzaki, Takashi</creatorcontrib><creatorcontrib>Ishida, Kiyomichi</creatorcontrib><creatorcontrib>Ito, Takeshi</creatorcontrib><creatorcontrib>Kurotaki, Takuji</creatorcontrib><creatorcontrib>Watanabe, Yasuo</creatorcontrib><creatorcontrib>Fukui, Toshio</creatorcontrib><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Matsuzaki, Takashi</au><au>Ishida, Kiyomichi</au><au>Ito, Takeshi</au><au>Kurotaki, Takuji</au><au>Watanabe, Yasuo</au><au>Fukui, Toshio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Static Pressure Measurement of High Enthalpy Flowin Arc-Heated Wind Tunnel</atitle><jtitle>JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES</jtitle><date>2002</date><risdate>2002</risdate><volume>50</volume><issue>585</issue><spage>426</spage><epage>426</epage><pages>426-426</pages><issn>1344-6460</issn><eissn>2432-3691</eissn><abstract>NAL has been promoting diagnostic study of the 750kW arc-heated wind tunnel flow to characterize various important flow parameters, such as heat flux and pressure, necessary for determining materials test conditions. In those measurement techniques, static pressure data is one of the most difficult experimental items to obtain. In this report, design of a static pressure probe and measurement system for the pressure, calibration system and the results, and evaluation of response time of the pressure are presented. The results show that static pressure distributions of the high enthalpy air flow in the NAL/NASDA 750kW arc-heated wind tunnel were obtained with good accuracy using these techniques.</abstract><cop>Tokyo</cop><pub>THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES</pub><doi>10.2322/jjsass.50.426</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1344-6460
ispartof JOURNAL OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, 2002, Vol.50(585), pp.426-426
issn 1344-6460
2432-3691
language eng ; jpn
recordid cdi_proquest_journals_1438000404
source EZB-FREE-00999 freely available EZB journals
subjects Arc-Heated Wind Tunnel
High Enthalpy Flow
Uniform Flow Evaluation
title Static Pressure Measurement of High Enthalpy Flowin Arc-Heated Wind Tunnel
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T13%3A28%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_jstag&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Static%20Pressure%20Measurement%20of%20High%20Enthalpy%20Flowin%20Arc-Heated%20Wind%20Tunnel&rft.jtitle=JOURNAL%20OF%20THE%20JAPAN%20SOCIETY%20FOR%20AERONAUTICAL%20AND%20SPACE%20SCIENCES&rft.au=Matsuzaki,%20Takashi&rft.date=2002&rft.volume=50&rft.issue=585&rft.spage=426&rft.epage=426&rft.pages=426-426&rft.issn=1344-6460&rft.eissn=2432-3691&rft_id=info:doi/10.2322/jjsass.50.426&rft_dat=%3Cproquest_jstag%3E3085960981%3C/proquest_jstag%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1438000404&rft_id=info:pmid/&rfr_iscdi=true