Patient-specific dosimetry for intracavitary ^sup 32^P-chromic phosphate colloid therapy of cystic brain tumours
^sup 32^P-chromic phosphate colloid treatments of astrocytoma and craniopharyngioma cystic brain tumours in paediatric patients are conventionally based on a sphere model under the assumption of uniform uptake. The aims of this study were to determine the distribution of the absorbed dose delivered...
Gespeichert in:
Veröffentlicht in: | European journal of nuclear medicine and molecular imaging 2013-10, Vol.40 (10), p.1532 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 10 |
container_start_page | 1532 |
container_title | European journal of nuclear medicine and molecular imaging |
container_volume | 40 |
creator | Denis-bacelar, Ana M Romanchikova, Marina Chittenden, Sarah Saran, Frank H Mandeville, Henry Du, Yong Flux, Glenn D |
description | ^sup 32^P-chromic phosphate colloid treatments of astrocytoma and craniopharyngioma cystic brain tumours in paediatric patients are conventionally based on a sphere model under the assumption of uniform uptake. The aims of this study were to determine the distribution of the absorbed dose delivered by ^sup 32^P on a patient-specific basis and to evaluate the accuracy with which this can be predicted from a pretherapy administration of ^sup 99m^Tc-Sn colloid. Three patients were treated with ^sup 32^P-chromic phosphate colloid following ^sup 99m^Tc-Sn colloid administrations. Convolution dosimetry was performed using pretherapy and posttherapy sequential SPECT imaging, and verified with EGSnrc Monte Carlo radiation transport simulations. Mean absorbed doses to the cyst wall and dose-volume histograms were also calculated and compared with those obtained by the sphere model approach. Highly nonuniform uptake distributions of both the ^sup 99m^Tc and ^sup 32^P colloids were observed and characterized by dose-volume histograms to the cyst wall. Mean absorbed doses delivered to the cyst wall, obtained with the convolution method, were on average 21 % (SD 18 %) and 50 % (SD 30 %) lower than those predicted by the ^sup 99m^Tc distribution and the uniform assumption of the sphere model, respectively. Absorbed doses delivered to the cyst wall by ^sup 32^P are more accurately predicted from image-based patient-specific convolution dosimetry than from simple sphere models. These results indicate the necessity to perform personalized treatment planning and verification for intracavitary irradiation of cystic brain tumours treated with radiocolloids. Patient-specific dosimetry can be used to guide the frequency and levels of repeated administrations and would facilitate data collection and comparison to support the multicentre trials necessary to progress this therapy.[PUBLICATION ABSTRACT] |
doi_str_mv | 10.1007/s00259-013-2451-6 |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_1434383507</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3077682581</sourcerecordid><originalsourceid>FETCH-proquest_journals_14343835073</originalsourceid><addsrcrecordid>eNqNyjFPwzAQBWCrolIL5QewWWI2nOOkSWYEYuzA3Mq4juIqybm-S6X8ezwgZqb39N4nxJOGFw1QvxJAUbUKtFFFWWm1X4mt3utW1dC0d3-9ho24J7oA6KZo2q2IB8vBT6woehe64OQZKYye0yI7TDJMnKyzt8A2L0eaozTF8aBcn3DMOvZIsbfspcNhwHCW3Ptk4yKxk24hzuY72TBJnkecE-3EurMD-cfffBDPH-9fb58qJrzOnvh0yWzK10mXpjSNqaA2_1M_4IJSTQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1434383507</pqid></control><display><type>article</type><title>Patient-specific dosimetry for intracavitary ^sup 32^P-chromic phosphate colloid therapy of cystic brain tumours</title><source>SpringerLink Journals - AutoHoldings</source><creator>Denis-bacelar, Ana M ; Romanchikova, Marina ; Chittenden, Sarah ; Saran, Frank H ; Mandeville, Henry ; Du, Yong ; Flux, Glenn D</creator><creatorcontrib>Denis-bacelar, Ana M ; Romanchikova, Marina ; Chittenden, Sarah ; Saran, Frank H ; Mandeville, Henry ; Du, Yong ; Flux, Glenn D</creatorcontrib><description>^sup 32^P-chromic phosphate colloid treatments of astrocytoma and craniopharyngioma cystic brain tumours in paediatric patients are conventionally based on a sphere model under the assumption of uniform uptake. The aims of this study were to determine the distribution of the absorbed dose delivered by ^sup 32^P on a patient-specific basis and to evaluate the accuracy with which this can be predicted from a pretherapy administration of ^sup 99m^Tc-Sn colloid. Three patients were treated with ^sup 32^P-chromic phosphate colloid following ^sup 99m^Tc-Sn colloid administrations. Convolution dosimetry was performed using pretherapy and posttherapy sequential SPECT imaging, and verified with EGSnrc Monte Carlo radiation transport simulations. Mean absorbed doses to the cyst wall and dose-volume histograms were also calculated and compared with those obtained by the sphere model approach. Highly nonuniform uptake distributions of both the ^sup 99m^Tc and ^sup 32^P colloids were observed and characterized by dose-volume histograms to the cyst wall. Mean absorbed doses delivered to the cyst wall, obtained with the convolution method, were on average 21 % (SD 18 %) and 50 % (SD 30 %) lower than those predicted by the ^sup 99m^Tc distribution and the uniform assumption of the sphere model, respectively. Absorbed doses delivered to the cyst wall by ^sup 32^P are more accurately predicted from image-based patient-specific convolution dosimetry than from simple sphere models. These results indicate the necessity to perform personalized treatment planning and verification for intracavitary irradiation of cystic brain tumours treated with radiocolloids. Patient-specific dosimetry can be used to guide the frequency and levels of repeated administrations and would facilitate data collection and comparison to support the multicentre trials necessary to progress this therapy.[PUBLICATION ABSTRACT]</description><identifier>ISSN: 1619-7070</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/s00259-013-2451-6</identifier><language>eng</language><publisher>Heidelberg: Springer Nature B.V</publisher><subject>Brain cancer ; Dosimetry ; Medical imaging ; Monte Carlo simulation ; Nuclear medicine</subject><ispartof>European journal of nuclear medicine and molecular imaging, 2013-10, Vol.40 (10), p.1532</ispartof><rights>Springer-Verlag Berlin Heidelberg 2013</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Denis-bacelar, Ana M</creatorcontrib><creatorcontrib>Romanchikova, Marina</creatorcontrib><creatorcontrib>Chittenden, Sarah</creatorcontrib><creatorcontrib>Saran, Frank H</creatorcontrib><creatorcontrib>Mandeville, Henry</creatorcontrib><creatorcontrib>Du, Yong</creatorcontrib><creatorcontrib>Flux, Glenn D</creatorcontrib><title>Patient-specific dosimetry for intracavitary ^sup 32^P-chromic phosphate colloid therapy of cystic brain tumours</title><title>European journal of nuclear medicine and molecular imaging</title><description>^sup 32^P-chromic phosphate colloid treatments of astrocytoma and craniopharyngioma cystic brain tumours in paediatric patients are conventionally based on a sphere model under the assumption of uniform uptake. The aims of this study were to determine the distribution of the absorbed dose delivered by ^sup 32^P on a patient-specific basis and to evaluate the accuracy with which this can be predicted from a pretherapy administration of ^sup 99m^Tc-Sn colloid. Three patients were treated with ^sup 32^P-chromic phosphate colloid following ^sup 99m^Tc-Sn colloid administrations. Convolution dosimetry was performed using pretherapy and posttherapy sequential SPECT imaging, and verified with EGSnrc Monte Carlo radiation transport simulations. Mean absorbed doses to the cyst wall and dose-volume histograms were also calculated and compared with those obtained by the sphere model approach. Highly nonuniform uptake distributions of both the ^sup 99m^Tc and ^sup 32^P colloids were observed and characterized by dose-volume histograms to the cyst wall. Mean absorbed doses delivered to the cyst wall, obtained with the convolution method, were on average 21 % (SD 18 %) and 50 % (SD 30 %) lower than those predicted by the ^sup 99m^Tc distribution and the uniform assumption of the sphere model, respectively. Absorbed doses delivered to the cyst wall by ^sup 32^P are more accurately predicted from image-based patient-specific convolution dosimetry than from simple sphere models. These results indicate the necessity to perform personalized treatment planning and verification for intracavitary irradiation of cystic brain tumours treated with radiocolloids. Patient-specific dosimetry can be used to guide the frequency and levels of repeated administrations and would facilitate data collection and comparison to support the multicentre trials necessary to progress this therapy.[PUBLICATION ABSTRACT]</description><subject>Brain cancer</subject><subject>Dosimetry</subject><subject>Medical imaging</subject><subject>Monte Carlo simulation</subject><subject>Nuclear medicine</subject><issn>1619-7070</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqNyjFPwzAQBWCrolIL5QewWWI2nOOkSWYEYuzA3Mq4juIqybm-S6X8ezwgZqb39N4nxJOGFw1QvxJAUbUKtFFFWWm1X4mt3utW1dC0d3-9ho24J7oA6KZo2q2IB8vBT6woehe64OQZKYye0yI7TDJMnKyzt8A2L0eaozTF8aBcn3DMOvZIsbfspcNhwHCW3Ptk4yKxk24hzuY72TBJnkecE-3EurMD-cfffBDPH-9fb58qJrzOnvh0yWzK10mXpjSNqaA2_1M_4IJSTQ</recordid><startdate>20131001</startdate><enddate>20131001</enddate><creator>Denis-bacelar, Ana M</creator><creator>Romanchikova, Marina</creator><creator>Chittenden, Sarah</creator><creator>Saran, Frank H</creator><creator>Mandeville, Henry</creator><creator>Du, Yong</creator><creator>Flux, Glenn D</creator><general>Springer Nature B.V</general><scope>3V.</scope><scope>7RV</scope><scope>7TK</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20131001</creationdate><title>Patient-specific dosimetry for intracavitary ^sup 32^P-chromic phosphate colloid therapy of cystic brain tumours</title><author>Denis-bacelar, Ana M ; Romanchikova, Marina ; Chittenden, Sarah ; Saran, Frank H ; Mandeville, Henry ; Du, Yong ; Flux, Glenn D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_14343835073</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Brain cancer</topic><topic>Dosimetry</topic><topic>Medical imaging</topic><topic>Monte Carlo simulation</topic><topic>Nuclear medicine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Denis-bacelar, Ana M</creatorcontrib><creatorcontrib>Romanchikova, Marina</creatorcontrib><creatorcontrib>Chittenden, Sarah</creatorcontrib><creatorcontrib>Saran, Frank H</creatorcontrib><creatorcontrib>Mandeville, Henry</creatorcontrib><creatorcontrib>Du, Yong</creatorcontrib><creatorcontrib>Flux, Glenn D</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Nursing & Allied Health Database</collection><collection>Neurosciences Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Nursing & Allied Health Premium</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>European journal of nuclear medicine and molecular imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Denis-bacelar, Ana M</au><au>Romanchikova, Marina</au><au>Chittenden, Sarah</au><au>Saran, Frank H</au><au>Mandeville, Henry</au><au>Du, Yong</au><au>Flux, Glenn D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Patient-specific dosimetry for intracavitary ^sup 32^P-chromic phosphate colloid therapy of cystic brain tumours</atitle><jtitle>European journal of nuclear medicine and molecular imaging</jtitle><date>2013-10-01</date><risdate>2013</risdate><volume>40</volume><issue>10</issue><spage>1532</spage><pages>1532-</pages><issn>1619-7070</issn><eissn>1619-7089</eissn><abstract>^sup 32^P-chromic phosphate colloid treatments of astrocytoma and craniopharyngioma cystic brain tumours in paediatric patients are conventionally based on a sphere model under the assumption of uniform uptake. The aims of this study were to determine the distribution of the absorbed dose delivered by ^sup 32^P on a patient-specific basis and to evaluate the accuracy with which this can be predicted from a pretherapy administration of ^sup 99m^Tc-Sn colloid. Three patients were treated with ^sup 32^P-chromic phosphate colloid following ^sup 99m^Tc-Sn colloid administrations. Convolution dosimetry was performed using pretherapy and posttherapy sequential SPECT imaging, and verified with EGSnrc Monte Carlo radiation transport simulations. Mean absorbed doses to the cyst wall and dose-volume histograms were also calculated and compared with those obtained by the sphere model approach. Highly nonuniform uptake distributions of both the ^sup 99m^Tc and ^sup 32^P colloids were observed and characterized by dose-volume histograms to the cyst wall. Mean absorbed doses delivered to the cyst wall, obtained with the convolution method, were on average 21 % (SD 18 %) and 50 % (SD 30 %) lower than those predicted by the ^sup 99m^Tc distribution and the uniform assumption of the sphere model, respectively. Absorbed doses delivered to the cyst wall by ^sup 32^P are more accurately predicted from image-based patient-specific convolution dosimetry than from simple sphere models. These results indicate the necessity to perform personalized treatment planning and verification for intracavitary irradiation of cystic brain tumours treated with radiocolloids. Patient-specific dosimetry can be used to guide the frequency and levels of repeated administrations and would facilitate data collection and comparison to support the multicentre trials necessary to progress this therapy.[PUBLICATION ABSTRACT]</abstract><cop>Heidelberg</cop><pub>Springer Nature B.V</pub><doi>10.1007/s00259-013-2451-6</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1619-7070 |
ispartof | European journal of nuclear medicine and molecular imaging, 2013-10, Vol.40 (10), p.1532 |
issn | 1619-7070 1619-7089 |
language | eng |
recordid | cdi_proquest_journals_1434383507 |
source | SpringerLink Journals - AutoHoldings |
subjects | Brain cancer Dosimetry Medical imaging Monte Carlo simulation Nuclear medicine |
title | Patient-specific dosimetry for intracavitary ^sup 32^P-chromic phosphate colloid therapy of cystic brain tumours |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T00%3A21%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Patient-specific%20dosimetry%20for%20intracavitary%20%5Esup%2032%5EP-chromic%20phosphate%20colloid%20therapy%20of%20cystic%20brain%20tumours&rft.jtitle=European%20journal%20of%20nuclear%20medicine%20and%20molecular%20imaging&rft.au=Denis-bacelar,%20Ana%20M&rft.date=2013-10-01&rft.volume=40&rft.issue=10&rft.spage=1532&rft.pages=1532-&rft.issn=1619-7070&rft.eissn=1619-7089&rft_id=info:doi/10.1007/s00259-013-2451-6&rft_dat=%3Cproquest%3E3077682581%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1434383507&rft_id=info:pmid/&rfr_iscdi=true |