Influence of Quadrature-Axis Reactance of Large Turbine Generator on Operation

Two-pole large generators are extensively used in power utilities. Growing demand for electric power in recent years has led to substantial increases in the capacity of generators. To meet this trend, we have manufactured 2 pole turbine generators in 900,000kVA to 1,200,000kVA classes. As the capaci...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku 2009/01/01, Vol.129(1), pp.93-100
Hauptverfasser: Hiramatsu, Daisuke, Uemura, Yoichi, Uemoto, Shinji, Okumoto, Junji, Imai, Takehiko, Kakiuchi, Mikio, Nagakura, Ken, Fujita, Masafumi, Otaka, Toru
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 100
container_issue 1
container_start_page 93
container_title Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku
container_volume 129
creator Hiramatsu, Daisuke
Uemura, Yoichi
Uemoto, Shinji
Okumoto, Junji
Imai, Takehiko
Kakiuchi, Mikio
Nagakura, Ken
Fujita, Masafumi
Otaka, Toru
description Two-pole large generators are extensively used in power utilities. Growing demand for electric power in recent years has led to substantial increases in the capacity of generators. To meet this trend, we have manufactured 2 pole turbine generators in 900,000kVA to 1,200,000kVA classes. As the capacity of generators becomes larger, equivalent circuits are increasingly expected to improve their precision in estimating operation characteristics. Park model has been widely used as an equivalent circuit model. Park model with quadrature axis transient reactance x'q is claimed to be useful for accurately estimating the load rejection characteristics of turbine generators. However it is difficult to measure the x'q, few studies have been reportedly carried out based on measured data. As one of the few examples, we have conducted a measured data on a 500,000kVA class generator. Recently, the authors obtained the test data of x'q of 900,000kVA class generator. In this study, based on these data, we studied the effect of x'q, using the finite element method (FEM) and transient analysis program (EMTP-ATP).
doi_str_mv 10.1541/ieejpes.129.93
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1433867376</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3076260711</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3153-b8f13152637f03aef39a772fd684ff6d5d6cbad66e6f2e438c35b5229875ebd23</originalsourceid><addsrcrecordid>eNpVkFFLwzAUhYMoOOZefS743NrkNmn6OKbOwXAo8zmk6c3smGlNWtB_v46VgS_3HjjfuRcOIfc0TSjP6GONuG8xJJQVSQFXZEIhk7GkWX5NJilIHmeMwi2ZhVCXacqLlEouJuRt5eyhR2cwamz03uvK6673GM9_6xB9oDadHs219juMtr0va4fREh0OaOOjxkWb9qTrxt2RG6sPAWfjnpLPl-ft4jVeb5arxXwdG6Ac4lJaOggmILcpaLRQ6DxnthIys1ZUvBKm1JUQKCzDDKQBXnLGCplzLCsGU_Jwvtv65qfH0Kl903s3vFQ0A5Aih1wMVHKmjG9C8GhV6-tv7f8UTdWpNjXWpobaVAFD4Okc2IdO7_CCa9_V5oD_cDrOAi62-dJeoYMjA5J6SQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1433867376</pqid></control><display><type>article</type><title>Influence of Quadrature-Axis Reactance of Large Turbine Generator on Operation</title><source>EZB Electronic Journals Library</source><creator>Hiramatsu, Daisuke ; Uemura, Yoichi ; Uemoto, Shinji ; Okumoto, Junji ; Imai, Takehiko ; Kakiuchi, Mikio ; Nagakura, Ken ; Fujita, Masafumi ; Otaka, Toru</creator><creatorcontrib>Hiramatsu, Daisuke ; Uemura, Yoichi ; Uemoto, Shinji ; Okumoto, Junji ; Imai, Takehiko ; Kakiuchi, Mikio ; Nagakura, Ken ; Fujita, Masafumi ; Otaka, Toru</creatorcontrib><description>Two-pole large generators are extensively used in power utilities. Growing demand for electric power in recent years has led to substantial increases in the capacity of generators. To meet this trend, we have manufactured 2 pole turbine generators in 900,000kVA to 1,200,000kVA classes. As the capacity of generators becomes larger, equivalent circuits are increasingly expected to improve their precision in estimating operation characteristics. Park model has been widely used as an equivalent circuit model. Park model with quadrature axis transient reactance x'q is claimed to be useful for accurately estimating the load rejection characteristics of turbine generators. However it is difficult to measure the x'q, few studies have been reportedly carried out based on measured data. As one of the few examples, we have conducted a measured data on a 500,000kVA class generator. Recently, the authors obtained the test data of x'q of 900,000kVA class generator. In this study, based on these data, we studied the effect of x'q, using the finite element method (FEM) and transient analysis program (EMTP-ATP).</description><identifier>ISSN: 0385-4213</identifier><identifier>EISSN: 1348-8147</identifier><identifier>DOI: 10.1541/ieejpes.129.93</identifier><language>eng</language><publisher>Tokyo: The Institute of Electrical Engineers of Japan</publisher><subject>EMTP ; FEM ; operational-impedance ; quadrature-axis reactance ; turbine-generator</subject><ispartof>IEEJ Transactions on Power and Energy, 2009/01/01, Vol.129(1), pp.93-100</ispartof><rights>2009 by the Institute of Electrical Engineers of Japan</rights><rights>Copyright Japan Science and Technology Agency 2009</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3153-b8f13152637f03aef39a772fd684ff6d5d6cbad66e6f2e438c35b5229875ebd23</citedby><cites>FETCH-LOGICAL-c3153-b8f13152637f03aef39a772fd684ff6d5d6cbad66e6f2e438c35b5229875ebd23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,4025,27928,27929,27930</link.rule.ids></links><search><creatorcontrib>Hiramatsu, Daisuke</creatorcontrib><creatorcontrib>Uemura, Yoichi</creatorcontrib><creatorcontrib>Uemoto, Shinji</creatorcontrib><creatorcontrib>Okumoto, Junji</creatorcontrib><creatorcontrib>Imai, Takehiko</creatorcontrib><creatorcontrib>Kakiuchi, Mikio</creatorcontrib><creatorcontrib>Nagakura, Ken</creatorcontrib><creatorcontrib>Fujita, Masafumi</creatorcontrib><creatorcontrib>Otaka, Toru</creatorcontrib><title>Influence of Quadrature-Axis Reactance of Large Turbine Generator on Operation</title><title>Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku</title><addtitle>IEEJ Trans. PE</addtitle><description>Two-pole large generators are extensively used in power utilities. Growing demand for electric power in recent years has led to substantial increases in the capacity of generators. To meet this trend, we have manufactured 2 pole turbine generators in 900,000kVA to 1,200,000kVA classes. As the capacity of generators becomes larger, equivalent circuits are increasingly expected to improve their precision in estimating operation characteristics. Park model has been widely used as an equivalent circuit model. Park model with quadrature axis transient reactance x'q is claimed to be useful for accurately estimating the load rejection characteristics of turbine generators. However it is difficult to measure the x'q, few studies have been reportedly carried out based on measured data. As one of the few examples, we have conducted a measured data on a 500,000kVA class generator. Recently, the authors obtained the test data of x'q of 900,000kVA class generator. In this study, based on these data, we studied the effect of x'q, using the finite element method (FEM) and transient analysis program (EMTP-ATP).</description><subject>EMTP</subject><subject>FEM</subject><subject>operational-impedance</subject><subject>quadrature-axis reactance</subject><subject>turbine-generator</subject><issn>0385-4213</issn><issn>1348-8147</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNpVkFFLwzAUhYMoOOZefS743NrkNmn6OKbOwXAo8zmk6c3smGlNWtB_v46VgS_3HjjfuRcOIfc0TSjP6GONuG8xJJQVSQFXZEIhk7GkWX5NJilIHmeMwi2ZhVCXacqLlEouJuRt5eyhR2cwamz03uvK6673GM9_6xB9oDadHs219juMtr0va4fREh0OaOOjxkWb9qTrxt2RG6sPAWfjnpLPl-ft4jVeb5arxXwdG6Ac4lJaOggmILcpaLRQ6DxnthIys1ZUvBKm1JUQKCzDDKQBXnLGCplzLCsGU_Jwvtv65qfH0Kl903s3vFQ0A5Aih1wMVHKmjG9C8GhV6-tv7f8UTdWpNjXWpobaVAFD4Okc2IdO7_CCa9_V5oD_cDrOAi62-dJeoYMjA5J6SQ</recordid><startdate>20090101</startdate><enddate>20090101</enddate><creator>Hiramatsu, Daisuke</creator><creator>Uemura, Yoichi</creator><creator>Uemoto, Shinji</creator><creator>Okumoto, Junji</creator><creator>Imai, Takehiko</creator><creator>Kakiuchi, Mikio</creator><creator>Nagakura, Ken</creator><creator>Fujita, Masafumi</creator><creator>Otaka, Toru</creator><general>The Institute of Electrical Engineers of Japan</general><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20090101</creationdate><title>Influence of Quadrature-Axis Reactance of Large Turbine Generator on Operation</title><author>Hiramatsu, Daisuke ; Uemura, Yoichi ; Uemoto, Shinji ; Okumoto, Junji ; Imai, Takehiko ; Kakiuchi, Mikio ; Nagakura, Ken ; Fujita, Masafumi ; Otaka, Toru</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3153-b8f13152637f03aef39a772fd684ff6d5d6cbad66e6f2e438c35b5229875ebd23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>EMTP</topic><topic>FEM</topic><topic>operational-impedance</topic><topic>quadrature-axis reactance</topic><topic>turbine-generator</topic><toplevel>online_resources</toplevel><creatorcontrib>Hiramatsu, Daisuke</creatorcontrib><creatorcontrib>Uemura, Yoichi</creatorcontrib><creatorcontrib>Uemoto, Shinji</creatorcontrib><creatorcontrib>Okumoto, Junji</creatorcontrib><creatorcontrib>Imai, Takehiko</creatorcontrib><creatorcontrib>Kakiuchi, Mikio</creatorcontrib><creatorcontrib>Nagakura, Ken</creatorcontrib><creatorcontrib>Fujita, Masafumi</creatorcontrib><creatorcontrib>Otaka, Toru</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hiramatsu, Daisuke</au><au>Uemura, Yoichi</au><au>Uemoto, Shinji</au><au>Okumoto, Junji</au><au>Imai, Takehiko</au><au>Kakiuchi, Mikio</au><au>Nagakura, Ken</au><au>Fujita, Masafumi</au><au>Otaka, Toru</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of Quadrature-Axis Reactance of Large Turbine Generator on Operation</atitle><jtitle>Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku</jtitle><addtitle>IEEJ Trans. PE</addtitle><date>2009-01-01</date><risdate>2009</risdate><volume>129</volume><issue>1</issue><spage>93</spage><epage>100</epage><pages>93-100</pages><issn>0385-4213</issn><eissn>1348-8147</eissn><abstract>Two-pole large generators are extensively used in power utilities. Growing demand for electric power in recent years has led to substantial increases in the capacity of generators. To meet this trend, we have manufactured 2 pole turbine generators in 900,000kVA to 1,200,000kVA classes. As the capacity of generators becomes larger, equivalent circuits are increasingly expected to improve their precision in estimating operation characteristics. Park model has been widely used as an equivalent circuit model. Park model with quadrature axis transient reactance x'q is claimed to be useful for accurately estimating the load rejection characteristics of turbine generators. However it is difficult to measure the x'q, few studies have been reportedly carried out based on measured data. As one of the few examples, we have conducted a measured data on a 500,000kVA class generator. Recently, the authors obtained the test data of x'q of 900,000kVA class generator. In this study, based on these data, we studied the effect of x'q, using the finite element method (FEM) and transient analysis program (EMTP-ATP).</abstract><cop>Tokyo</cop><pub>The Institute of Electrical Engineers of Japan</pub><doi>10.1541/ieejpes.129.93</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0385-4213
ispartof IEEJ Transactions on Power and Energy, 2009/01/01, Vol.129(1), pp.93-100
issn 0385-4213
1348-8147
language eng
recordid cdi_proquest_journals_1433867376
source EZB Electronic Journals Library
subjects EMTP
FEM
operational-impedance
quadrature-axis reactance
turbine-generator
title Influence of Quadrature-Axis Reactance of Large Turbine Generator on Operation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-13T17%3A08%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20Quadrature-Axis%20Reactance%20of%20Large%20Turbine%20Generator%20on%20Operation&rft.jtitle=Denki%20Gakkai%20ronbunshi.%20B,%20Enerugi,%20denki%20kiki,%20denryoku&rft.au=Hiramatsu,%20Daisuke&rft.date=2009-01-01&rft.volume=129&rft.issue=1&rft.spage=93&rft.epage=100&rft.pages=93-100&rft.issn=0385-4213&rft.eissn=1348-8147&rft_id=info:doi/10.1541/ieejpes.129.93&rft_dat=%3Cproquest_cross%3E3076260711%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1433867376&rft_id=info:pmid/&rfr_iscdi=true