Lightning Surge Analysis for 500-kV Transmission Lines using Grounding Model with Dynamic Characteristics
It is well known that grounding resistance under huge lightning current injection has current-dependent characteristics, whose mathematical model was already proposed by Liew and Darveniza in 1974. In this paper, where our final goal is reasonable design for lightning protection of 500-kV transmissi...
Gespeichert in:
Veröffentlicht in: | Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku Enerugi, denki kiki, denryoku, 2003, Vol.123 (2), p.245-251 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 251 |
---|---|
container_issue | 2 |
container_start_page | 245 |
container_title | Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku |
container_volume | 123 |
creator | Yasuda, Yoh Kondo, Shuhei Hara, Takehisa Ikeda, Keiichi Sonoi, Yasuo Furuoka, Yoshihiro |
description | It is well known that grounding resistance under huge lightning current injection has current-dependent characteristics, whose mathematical model was already proposed by Liew and Darveniza in 1974. In this paper, where our final goal is reasonable design for lightning protection of 500-kV transmission tower, we adopt the dynamic grounding-resistance model to MODELS-ATP simulation. The effect of the model for the lightning surge analysis on 500-kV transmission line systems is discussed in detail. |
doi_str_mv | 10.1541/ieejpes.123.245 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1433849729</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3076092741</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2255-7ab9ebc1eb0fe72faabbffdc17e76a2d00a0d319101f871a9842f523b1ec9b53</originalsourceid><addsrcrecordid>eNotkD1PwzAYhC0EEqUws1piTuvXHyQZqwIFKYiBitVyHLt1aZ3iNxHqv2-qdrob7k66h5BHYBNQEqbBuc3e4QS4mHCprsgIhCyyAmR-TUZMFCqTHMQtuUPcMCaEksWIhCqs1l0McUW_-7RydBbN9oABqW8TVYxlvz90mUzEXUAMbaRViA5pj6fKIrV9bE7us23clv6Hbk1fDtHsgqXztUnGdi4F7ILFe3LjzRbdw0XHZPn2upy_Z9XX4mM-qzLLuVJZburS1RZczbzLuTemrr1vLOQufza8YcywRkAJDHyRgykLyb3iogZny1qJMXk6z-5T-9c77PSm7dNwCjVIIQpZ5rwcUtNzyqYWMTmv9ynsTDpoYPqEU19w6gGnHnCKI5oTa34</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1433849729</pqid></control><display><type>article</type><title>Lightning Surge Analysis for 500-kV Transmission Lines using Grounding Model with Dynamic Characteristics</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Yasuda, Yoh ; Kondo, Shuhei ; Hara, Takehisa ; Ikeda, Keiichi ; Sonoi, Yasuo ; Furuoka, Yoshihiro</creator><creatorcontrib>Yasuda, Yoh ; Kondo, Shuhei ; Hara, Takehisa ; Ikeda, Keiichi ; Sonoi, Yasuo ; Furuoka, Yoshihiro</creatorcontrib><description>It is well known that grounding resistance under huge lightning current injection has current-dependent characteristics, whose mathematical model was already proposed by Liew and Darveniza in 1974. In this paper, where our final goal is reasonable design for lightning protection of 500-kV transmission tower, we adopt the dynamic grounding-resistance model to MODELS-ATP simulation. The effect of the model for the lightning surge analysis on 500-kV transmission line systems is discussed in detail.</description><identifier>ISSN: 0385-4213</identifier><identifier>EISSN: 1348-8147</identifier><identifier>DOI: 10.1541/ieejpes.123.245</identifier><language>eng</language><publisher>Tokyo: Japan Science and Technology Agency</publisher><ispartof>Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku, 2003, Vol.123 (2), p.245-251</ispartof><rights>Copyright Japan Science and Technology Agency 2003</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2255-7ab9ebc1eb0fe72faabbffdc17e76a2d00a0d319101f871a9842f523b1ec9b53</citedby><cites>FETCH-LOGICAL-c2255-7ab9ebc1eb0fe72faabbffdc17e76a2d00a0d319101f871a9842f523b1ec9b53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27900,27901,27902</link.rule.ids></links><search><creatorcontrib>Yasuda, Yoh</creatorcontrib><creatorcontrib>Kondo, Shuhei</creatorcontrib><creatorcontrib>Hara, Takehisa</creatorcontrib><creatorcontrib>Ikeda, Keiichi</creatorcontrib><creatorcontrib>Sonoi, Yasuo</creatorcontrib><creatorcontrib>Furuoka, Yoshihiro</creatorcontrib><title>Lightning Surge Analysis for 500-kV Transmission Lines using Grounding Model with Dynamic Characteristics</title><title>Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku</title><description>It is well known that grounding resistance under huge lightning current injection has current-dependent characteristics, whose mathematical model was already proposed by Liew and Darveniza in 1974. In this paper, where our final goal is reasonable design for lightning protection of 500-kV transmission tower, we adopt the dynamic grounding-resistance model to MODELS-ATP simulation. The effect of the model for the lightning surge analysis on 500-kV transmission line systems is discussed in detail.</description><issn>0385-4213</issn><issn>1348-8147</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNotkD1PwzAYhC0EEqUws1piTuvXHyQZqwIFKYiBitVyHLt1aZ3iNxHqv2-qdrob7k66h5BHYBNQEqbBuc3e4QS4mHCprsgIhCyyAmR-TUZMFCqTHMQtuUPcMCaEksWIhCqs1l0McUW_-7RydBbN9oABqW8TVYxlvz90mUzEXUAMbaRViA5pj6fKIrV9bE7us23clv6Hbk1fDtHsgqXztUnGdi4F7ILFe3LjzRbdw0XHZPn2upy_Z9XX4mM-qzLLuVJZburS1RZczbzLuTemrr1vLOQufza8YcywRkAJDHyRgykLyb3iogZny1qJMXk6z-5T-9c77PSm7dNwCjVIIQpZ5rwcUtNzyqYWMTmv9ynsTDpoYPqEU19w6gGnHnCKI5oTa34</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>Yasuda, Yoh</creator><creator>Kondo, Shuhei</creator><creator>Hara, Takehisa</creator><creator>Ikeda, Keiichi</creator><creator>Sonoi, Yasuo</creator><creator>Furuoka, Yoshihiro</creator><general>Japan Science and Technology Agency</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>2003</creationdate><title>Lightning Surge Analysis for 500-kV Transmission Lines using Grounding Model with Dynamic Characteristics</title><author>Yasuda, Yoh ; Kondo, Shuhei ; Hara, Takehisa ; Ikeda, Keiichi ; Sonoi, Yasuo ; Furuoka, Yoshihiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2255-7ab9ebc1eb0fe72faabbffdc17e76a2d00a0d319101f871a9842f523b1ec9b53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Yasuda, Yoh</creatorcontrib><creatorcontrib>Kondo, Shuhei</creatorcontrib><creatorcontrib>Hara, Takehisa</creatorcontrib><creatorcontrib>Ikeda, Keiichi</creatorcontrib><creatorcontrib>Sonoi, Yasuo</creatorcontrib><creatorcontrib>Furuoka, Yoshihiro</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yasuda, Yoh</au><au>Kondo, Shuhei</au><au>Hara, Takehisa</au><au>Ikeda, Keiichi</au><au>Sonoi, Yasuo</au><au>Furuoka, Yoshihiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Lightning Surge Analysis for 500-kV Transmission Lines using Grounding Model with Dynamic Characteristics</atitle><jtitle>Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku</jtitle><date>2003</date><risdate>2003</risdate><volume>123</volume><issue>2</issue><spage>245</spage><epage>251</epage><pages>245-251</pages><issn>0385-4213</issn><eissn>1348-8147</eissn><abstract>It is well known that grounding resistance under huge lightning current injection has current-dependent characteristics, whose mathematical model was already proposed by Liew and Darveniza in 1974. In this paper, where our final goal is reasonable design for lightning protection of 500-kV transmission tower, we adopt the dynamic grounding-resistance model to MODELS-ATP simulation. The effect of the model for the lightning surge analysis on 500-kV transmission line systems is discussed in detail.</abstract><cop>Tokyo</cop><pub>Japan Science and Technology Agency</pub><doi>10.1541/ieejpes.123.245</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0385-4213 |
ispartof | Denki Gakkai ronbunshi. B, Enerugi, denki kiki, denryoku, 2003, Vol.123 (2), p.245-251 |
issn | 0385-4213 1348-8147 |
language | eng |
recordid | cdi_proquest_journals_1433849729 |
source | EZB-FREE-00999 freely available EZB journals |
title | Lightning Surge Analysis for 500-kV Transmission Lines using Grounding Model with Dynamic Characteristics |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T04%3A14%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Lightning%20Surge%20Analysis%20for%20500-kV%20Transmission%20Lines%20using%20Grounding%20Model%20with%20Dynamic%20Characteristics&rft.jtitle=Denki%20Gakkai%20ronbunshi.%20B,%20Enerugi,%20denki%20kiki,%20denryoku&rft.au=Yasuda,%20Yoh&rft.date=2003&rft.volume=123&rft.issue=2&rft.spage=245&rft.epage=251&rft.pages=245-251&rft.issn=0385-4213&rft.eissn=1348-8147&rft_id=info:doi/10.1541/ieejpes.123.245&rft_dat=%3Cproquest_cross%3E3076092741%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1433849729&rft_id=info:pmid/&rfr_iscdi=true |