Validation of the RightSpot(TM) device for determination of gastric pH during nasogastric tube placement: Doc 147

The RightSpotpH(TM) indicator is a new device designed to facilitate pH-based confirmation of nasogastric tube placement while minimizing exposure of the operator to nasogastric contents. Study objectives: In vivo and in vitro validation of the RightSpotpH(TM) indicator. Patients (23) undergoing gen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of emergency medicine 2013-07, Vol.6
Hauptverfasser: Lambert, Charles R, Varlotta, David, Posey, Marjorie, Heberlein, Jadie L, Shirley, Janice M
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title International journal of emergency medicine
container_volume 6
creator Lambert, Charles R
Varlotta, David
Posey, Marjorie
Heberlein, Jadie L
Shirley, Janice M
description The RightSpotpH(TM) indicator is a new device designed to facilitate pH-based confirmation of nasogastric tube placement while minimizing exposure of the operator to nasogastric contents. Study objectives: In vivo and in vitro validation of the RightSpotpH(TM) indicator. Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode catheter following endotracheal intubation. Direct intragastric pH was recorded simultaneously with gastric aspirate pH using the RightSpotpH(TM) indicator as well as an external pH electrode. In vitro validation of the RightSpotpH(TM) indicator was performed using standard buffer solutions. Electrode catheter-determined intragastric pH was compared to the RightSpotpH(TM) indicator result (pH greater or less than 4.5) as was aspirate pH using an external pH electrode. The positive predictive value for the RightSpotpH(TM) indicator was 0.92 (95% CI 0.62-0.99) and negative predictive value was 1.0 (95% CI 0.48-1.0) when compared to the direct catheter intragastric pH determination. This corresponds to a sensitivity of 1.0 and specificity of 0.83. The positive predictive value for the RightSpotpH(TM) indicator was 1.0 (95% CI 0.29-0.99) and negative predictive value was 0.75 (95% CI 0.19-0.99) when compared to the external pH electrode determination of aspirate. This corresponds to a sensitivity of 0.91 and specificity of 1.0. Blinded in vitro testing of 46 buffer solution samples of pH 2-7 yielded sensitivity and specificity for correct pH discrimination of 1.0 and 1.0. The RightSpotpH(TM) indicator is sensitive and specific for determination of intragastric pH determination as less than or greater than 4.5 as commonly used for nasogastric tube placement.[PUBLICATION ABSTRACT]
doi_str_mv 10.1186/1865-1380-6-28
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_1416632443</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3034431431</sourcerecordid><originalsourceid>FETCH-proquest_journals_14166324433</originalsourceid><addsrcrecordid>eNqNij0PgjAURRsTE_FjdX6Jiw4oFWzYjcbFRYkrqfCAGmixffj7ZVBnh5t7c-5hbM6DNeex2PTZ-TyMA1_423jAvB8YsbFzjyAQPBLcY9VN1iqXpIwGUwBVCBdVVnRtDS2T8wpyfKkMoTC2n4S2Ufpnl9KRVRm0J8g7q3QJWjrzpdTdEdpaZtigpikbFrJ2OPv0hC2Oh2R_8ltrnh06Sh-ms7q_Uh5xIcJtFIXhf9YbvshLjw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1416632443</pqid></control><display><type>article</type><title>Validation of the RightSpot(TM) device for determination of gastric pH during nasogastric tube placement: Doc 147</title><source>DOAJ Directory of Open Access Journals</source><source>PubMed Central Open Access</source><source>Springer Nature OA Free Journals</source><source>BioMedCentral</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><source>SpringerLink Journals - AutoHoldings</source><creator>Lambert, Charles R ; Varlotta, David ; Posey, Marjorie ; Heberlein, Jadie L ; Shirley, Janice M</creator><creatorcontrib>Lambert, Charles R ; Varlotta, David ; Posey, Marjorie ; Heberlein, Jadie L ; Shirley, Janice M</creatorcontrib><description>The RightSpotpH(TM) indicator is a new device designed to facilitate pH-based confirmation of nasogastric tube placement while minimizing exposure of the operator to nasogastric contents. Study objectives: In vivo and in vitro validation of the RightSpotpH(TM) indicator. Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode catheter following endotracheal intubation. Direct intragastric pH was recorded simultaneously with gastric aspirate pH using the RightSpotpH(TM) indicator as well as an external pH electrode. In vitro validation of the RightSpotpH(TM) indicator was performed using standard buffer solutions. Electrode catheter-determined intragastric pH was compared to the RightSpotpH(TM) indicator result (pH greater or less than 4.5) as was aspirate pH using an external pH electrode. The positive predictive value for the RightSpotpH(TM) indicator was 0.92 (95% CI 0.62-0.99) and negative predictive value was 1.0 (95% CI 0.48-1.0) when compared to the direct catheter intragastric pH determination. This corresponds to a sensitivity of 1.0 and specificity of 0.83. The positive predictive value for the RightSpotpH(TM) indicator was 1.0 (95% CI 0.29-0.99) and negative predictive value was 0.75 (95% CI 0.19-0.99) when compared to the external pH electrode determination of aspirate. This corresponds to a sensitivity of 0.91 and specificity of 1.0. Blinded in vitro testing of 46 buffer solution samples of pH 2-7 yielded sensitivity and specificity for correct pH discrimination of 1.0 and 1.0. The RightSpotpH(TM) indicator is sensitive and specific for determination of intragastric pH determination as less than or greater than 4.5 as commonly used for nasogastric tube placement.[PUBLICATION ABSTRACT]</description><identifier>EISSN: 1865-1380</identifier><identifier>DOI: 10.1186/1865-1380-6-28</identifier><language>eng</language><publisher>London: Springer Nature B.V</publisher><ispartof>International journal of emergency medicine, 2013-07, Vol.6</ispartof><rights>The Author(s) 2013</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27923,27924</link.rule.ids></links><search><creatorcontrib>Lambert, Charles R</creatorcontrib><creatorcontrib>Varlotta, David</creatorcontrib><creatorcontrib>Posey, Marjorie</creatorcontrib><creatorcontrib>Heberlein, Jadie L</creatorcontrib><creatorcontrib>Shirley, Janice M</creatorcontrib><title>Validation of the RightSpot(TM) device for determination of gastric pH during nasogastric tube placement: Doc 147</title><title>International journal of emergency medicine</title><description>The RightSpotpH(TM) indicator is a new device designed to facilitate pH-based confirmation of nasogastric tube placement while minimizing exposure of the operator to nasogastric contents. Study objectives: In vivo and in vitro validation of the RightSpotpH(TM) indicator. Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode catheter following endotracheal intubation. Direct intragastric pH was recorded simultaneously with gastric aspirate pH using the RightSpotpH(TM) indicator as well as an external pH electrode. In vitro validation of the RightSpotpH(TM) indicator was performed using standard buffer solutions. Electrode catheter-determined intragastric pH was compared to the RightSpotpH(TM) indicator result (pH greater or less than 4.5) as was aspirate pH using an external pH electrode. The positive predictive value for the RightSpotpH(TM) indicator was 0.92 (95% CI 0.62-0.99) and negative predictive value was 1.0 (95% CI 0.48-1.0) when compared to the direct catheter intragastric pH determination. This corresponds to a sensitivity of 1.0 and specificity of 0.83. The positive predictive value for the RightSpotpH(TM) indicator was 1.0 (95% CI 0.29-0.99) and negative predictive value was 0.75 (95% CI 0.19-0.99) when compared to the external pH electrode determination of aspirate. This corresponds to a sensitivity of 0.91 and specificity of 1.0. Blinded in vitro testing of 46 buffer solution samples of pH 2-7 yielded sensitivity and specificity for correct pH discrimination of 1.0 and 1.0. The RightSpotpH(TM) indicator is sensitive and specific for determination of intragastric pH determination as less than or greater than 4.5 as commonly used for nasogastric tube placement.[PUBLICATION ABSTRACT]</description><issn>1865-1380</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNij0PgjAURRsTE_FjdX6Jiw4oFWzYjcbFRYkrqfCAGmixffj7ZVBnh5t7c-5hbM6DNeex2PTZ-TyMA1_423jAvB8YsbFzjyAQPBLcY9VN1iqXpIwGUwBVCBdVVnRtDS2T8wpyfKkMoTC2n4S2Ufpnl9KRVRm0J8g7q3QJWjrzpdTdEdpaZtigpikbFrJ2OPv0hC2Oh2R_8ltrnh06Sh-ms7q_Uh5xIcJtFIXhf9YbvshLjw</recordid><startdate>20130701</startdate><enddate>20130701</enddate><creator>Lambert, Charles R</creator><creator>Varlotta, David</creator><creator>Posey, Marjorie</creator><creator>Heberlein, Jadie L</creator><creator>Shirley, Janice M</creator><general>Springer Nature B.V</general><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>NAPCQ</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20130701</creationdate><title>Validation of the RightSpot(TM) device for determination of gastric pH during nasogastric tube placement</title><author>Lambert, Charles R ; Varlotta, David ; Posey, Marjorie ; Heberlein, Jadie L ; Shirley, Janice M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_14166324433</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lambert, Charles R</creatorcontrib><creatorcontrib>Varlotta, David</creatorcontrib><creatorcontrib>Posey, Marjorie</creatorcontrib><creatorcontrib>Heberlein, Jadie L</creatorcontrib><creatorcontrib>Shirley, Janice M</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>International journal of emergency medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lambert, Charles R</au><au>Varlotta, David</au><au>Posey, Marjorie</au><au>Heberlein, Jadie L</au><au>Shirley, Janice M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Validation of the RightSpot(TM) device for determination of gastric pH during nasogastric tube placement: Doc 147</atitle><jtitle>International journal of emergency medicine</jtitle><date>2013-07-01</date><risdate>2013</risdate><volume>6</volume><eissn>1865-1380</eissn><abstract>The RightSpotpH(TM) indicator is a new device designed to facilitate pH-based confirmation of nasogastric tube placement while minimizing exposure of the operator to nasogastric contents. Study objectives: In vivo and in vitro validation of the RightSpotpH(TM) indicator. Patients (23) undergoing general anesthesia had placement of a nasogastric tube and gastric pH electrode catheter following endotracheal intubation. Direct intragastric pH was recorded simultaneously with gastric aspirate pH using the RightSpotpH(TM) indicator as well as an external pH electrode. In vitro validation of the RightSpotpH(TM) indicator was performed using standard buffer solutions. Electrode catheter-determined intragastric pH was compared to the RightSpotpH(TM) indicator result (pH greater or less than 4.5) as was aspirate pH using an external pH electrode. The positive predictive value for the RightSpotpH(TM) indicator was 0.92 (95% CI 0.62-0.99) and negative predictive value was 1.0 (95% CI 0.48-1.0) when compared to the direct catheter intragastric pH determination. This corresponds to a sensitivity of 1.0 and specificity of 0.83. The positive predictive value for the RightSpotpH(TM) indicator was 1.0 (95% CI 0.29-0.99) and negative predictive value was 0.75 (95% CI 0.19-0.99) when compared to the external pH electrode determination of aspirate. This corresponds to a sensitivity of 0.91 and specificity of 1.0. Blinded in vitro testing of 46 buffer solution samples of pH 2-7 yielded sensitivity and specificity for correct pH discrimination of 1.0 and 1.0. The RightSpotpH(TM) indicator is sensitive and specific for determination of intragastric pH determination as less than or greater than 4.5 as commonly used for nasogastric tube placement.[PUBLICATION ABSTRACT]</abstract><cop>London</cop><pub>Springer Nature B.V</pub><doi>10.1186/1865-1380-6-28</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 1865-1380
ispartof International journal of emergency medicine, 2013-07, Vol.6
issn 1865-1380
language eng
recordid cdi_proquest_journals_1416632443
source DOAJ Directory of Open Access Journals; PubMed Central Open Access; Springer Nature OA Free Journals; BioMedCentral; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection; SpringerLink Journals - AutoHoldings
title Validation of the RightSpot(TM) device for determination of gastric pH during nasogastric tube placement: Doc 147
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T13%3A07%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Validation%20of%20the%20RightSpot(TM)%20device%20for%20determination%20of%20gastric%20pH%20during%20nasogastric%20tube%20placement:%20Doc%20147&rft.jtitle=International%20journal%20of%20emergency%20medicine&rft.au=Lambert,%20Charles%20R&rft.date=2013-07-01&rft.volume=6&rft.eissn=1865-1380&rft_id=info:doi/10.1186/1865-1380-6-28&rft_dat=%3Cproquest%3E3034431431%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1416632443&rft_id=info:pmid/&rfr_iscdi=true