Computed microtomography (/spl mu/CT) with unmonochromatized synchrotron X-rays for cancerous human breast tissue and mouse vertebra

The use of X-ray computed microtomography (PCT) has increased in biomedical research and industrial applications. The inherited high quality of synchrotron radiation (SR) X-rays including high flux, collimation, and coherence, has been used recently to produce radiographic images with high spatial r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2002-10, Vol.49 (5), p.2262-2267
Hauptverfasser: Jung, Haijo, Kim, Hee-Joung, Hong, Soonil, Hong, Jin-O, Jeong, Ha-Kyu, Je, Jung Ho, Kim, Bo-Ra, Yoo, Hyung-Sik
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2267
container_issue 5
container_start_page 2262
container_title IEEE transactions on nuclear science
container_volume 49
creator Jung, Haijo
Kim, Hee-Joung
Hong, Soonil
Hong, Jin-O
Jeong, Ha-Kyu
Je, Jung Ho
Kim, Bo-Ra
Yoo, Hyung-Sik
description The use of X-ray computed microtomography (PCT) has increased in biomedical research and industrial applications. The inherited high quality of synchrotron radiation (SR) X-rays including high flux, collimation, and coherence, has been used recently to produce radiographic images with high spatial resolution and contrast. A simple and stable imaging system using an unmonochromatized SR source based on the principle of phase contrast X-ray imaging consists of a charge-coupled device (CCD) detector coupled with an optical lens system at the Pohang Light Source (PLS) 5C1 beamline. The spatial resolution of the imaging system was determined using the modulation transfer function (MTF), which was measured by step-by step calculations obtained from sharp edge images. Projection image data were obtained at 250 steps over 180 degrees of rotation with an acquisition time, depending on the imaged object materials, of 30 to 150 ms per projection image. The tomographic images were reconstructed using a simple filtered backprojection algorithm to reconstruct two-dimensional (2-D) images using projection data which may include characteristics of beam collimation and phase contrast. Although the use of a monochromatic X-ray beam has previously demonstrated to provide high resolution and enhanced contrast, our approach uses an unmonochromatized SR X-ray beam and shows similar image capability, without the needs for sophisticated X-ray optics, in an exposure time which is significantly less, by two orders of magnitude, than that for the monochromatic SR system. The current PLS 5C1 SR imaging system can produce projection images at a spatial resolution of 8.3 /spl mu/m over a field of view of about 5 mm at an exposure time of 30 ms per projection image for 1.5 /spl times/ optical magnification. This study presents the results of SR /spl mu/CT images of cancerous human breast tissue containing microcalcifications, mouse lumbar vertebra, and mouse coccygeal vertebra. The unmonochromatized SR /spl mu/CT imaging system provides an effective means of evaluating microstructures, not only in biomedical specimens but also in inorganic samples.
doi_str_mv 10.1109/TNS.2002.803814
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_journals_1018688939</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1046821</ieee_id><sourcerecordid>1671327758</sourcerecordid><originalsourceid>FETCH-LOGICAL-c351t-35f23632b137d124ae436532e4e66c296db811b6efc4e2f028643317a308d90e3</originalsourceid><addsrcrecordid>eNp9kT1vFDEQhq0IJI5ATZHGEhJKir3z-Gu9JTpBEimCgkOiW3n3ZrmNzvbG9gYdNT8cny5FREE1Gs3zztdLyDtgSwDWrDZfvi05Y3xpmDAgz8gClDIVqNq8IAvGwFSNbJpX5HVK9yWViqkF-bMObpozbqkb-xhycOFntNPuQC9XadpTN6_Wmyv6a8w7OnsXfOh3MTibx99Fkw7-mOYYPP1RRXtIdAiR9tb3GMOc6G521tMuok2Z5jGlGan1ZVgpIn3EmLGL9g15Odh9wrdP8Zx8__xps76p7r5e364_3lW9UJAroQYutOAdiHoLXFqUQivBUaLWPW_0tjMAncahl8gHxo2WQkBtBTPbhqE4Jx9OfacYHmZMuXVj6nG_tx7LQi03HEBJXsDL_4KgaxC8rpUp6Pt_0PswR1_OaKH8XBvTiKZQqxNVfpxSxKGd4uhsPBSoPdrXFvvao33tyb6iuDgpRkR8RktdlhR_AX5Flt0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1018688939</pqid></control><display><type>article</type><title>Computed microtomography (/spl mu/CT) with unmonochromatized synchrotron X-rays for cancerous human breast tissue and mouse vertebra</title><source>IEEE Electronic Library (IEL)</source><creator>Jung, Haijo ; Kim, Hee-Joung ; Hong, Soonil ; Hong, Jin-O ; Jeong, Ha-Kyu ; Je, Jung Ho ; Kim, Bo-Ra ; Yoo, Hyung-Sik</creator><creatorcontrib>Jung, Haijo ; Kim, Hee-Joung ; Hong, Soonil ; Hong, Jin-O ; Jeong, Ha-Kyu ; Je, Jung Ho ; Kim, Bo-Ra ; Yoo, Hyung-Sik</creatorcontrib><description>The use of X-ray computed microtomography (PCT) has increased in biomedical research and industrial applications. The inherited high quality of synchrotron radiation (SR) X-rays including high flux, collimation, and coherence, has been used recently to produce radiographic images with high spatial resolution and contrast. A simple and stable imaging system using an unmonochromatized SR source based on the principle of phase contrast X-ray imaging consists of a charge-coupled device (CCD) detector coupled with an optical lens system at the Pohang Light Source (PLS) 5C1 beamline. The spatial resolution of the imaging system was determined using the modulation transfer function (MTF), which was measured by step-by step calculations obtained from sharp edge images. Projection image data were obtained at 250 steps over 180 degrees of rotation with an acquisition time, depending on the imaged object materials, of 30 to 150 ms per projection image. The tomographic images were reconstructed using a simple filtered backprojection algorithm to reconstruct two-dimensional (2-D) images using projection data which may include characteristics of beam collimation and phase contrast. Although the use of a monochromatic X-ray beam has previously demonstrated to provide high resolution and enhanced contrast, our approach uses an unmonochromatized SR X-ray beam and shows similar image capability, without the needs for sophisticated X-ray optics, in an exposure time which is significantly less, by two orders of magnitude, than that for the monochromatic SR system. The current PLS 5C1 SR imaging system can produce projection images at a spatial resolution of 8.3 /spl mu/m over a field of view of about 5 mm at an exposure time of 30 ms per projection image for 1.5 /spl times/ optical magnification. This study presents the results of SR /spl mu/CT images of cancerous human breast tissue containing microcalcifications, mouse lumbar vertebra, and mouse coccygeal vertebra. The unmonochromatized SR /spl mu/CT imaging system provides an effective means of evaluating microstructures, not only in biomedical specimens but also in inorganic samples.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2002.803814</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Beams (radiation) ; Biomedical optical imaging ; Biomedical research ; Breast tissue ; Charge coupled devices ; Humans ; Image contrast ; Imaging ; Mice ; Optical filters ; Optical imaging ; Projection ; Spatial resolution ; Strontium ; Synchrotrons ; X-rays</subject><ispartof>IEEE transactions on nuclear science, 2002-10, Vol.49 (5), p.2262-2267</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2002</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c351t-35f23632b137d124ae436532e4e66c296db811b6efc4e2f028643317a308d90e3</citedby><cites>FETCH-LOGICAL-c351t-35f23632b137d124ae436532e4e66c296db811b6efc4e2f028643317a308d90e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1046821$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/1046821$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Jung, Haijo</creatorcontrib><creatorcontrib>Kim, Hee-Joung</creatorcontrib><creatorcontrib>Hong, Soonil</creatorcontrib><creatorcontrib>Hong, Jin-O</creatorcontrib><creatorcontrib>Jeong, Ha-Kyu</creatorcontrib><creatorcontrib>Je, Jung Ho</creatorcontrib><creatorcontrib>Kim, Bo-Ra</creatorcontrib><creatorcontrib>Yoo, Hyung-Sik</creatorcontrib><title>Computed microtomography (/spl mu/CT) with unmonochromatized synchrotron X-rays for cancerous human breast tissue and mouse vertebra</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>The use of X-ray computed microtomography (PCT) has increased in biomedical research and industrial applications. The inherited high quality of synchrotron radiation (SR) X-rays including high flux, collimation, and coherence, has been used recently to produce radiographic images with high spatial resolution and contrast. A simple and stable imaging system using an unmonochromatized SR source based on the principle of phase contrast X-ray imaging consists of a charge-coupled device (CCD) detector coupled with an optical lens system at the Pohang Light Source (PLS) 5C1 beamline. The spatial resolution of the imaging system was determined using the modulation transfer function (MTF), which was measured by step-by step calculations obtained from sharp edge images. Projection image data were obtained at 250 steps over 180 degrees of rotation with an acquisition time, depending on the imaged object materials, of 30 to 150 ms per projection image. The tomographic images were reconstructed using a simple filtered backprojection algorithm to reconstruct two-dimensional (2-D) images using projection data which may include characteristics of beam collimation and phase contrast. Although the use of a monochromatic X-ray beam has previously demonstrated to provide high resolution and enhanced contrast, our approach uses an unmonochromatized SR X-ray beam and shows similar image capability, without the needs for sophisticated X-ray optics, in an exposure time which is significantly less, by two orders of magnitude, than that for the monochromatic SR system. The current PLS 5C1 SR imaging system can produce projection images at a spatial resolution of 8.3 /spl mu/m over a field of view of about 5 mm at an exposure time of 30 ms per projection image for 1.5 /spl times/ optical magnification. This study presents the results of SR /spl mu/CT images of cancerous human breast tissue containing microcalcifications, mouse lumbar vertebra, and mouse coccygeal vertebra. The unmonochromatized SR /spl mu/CT imaging system provides an effective means of evaluating microstructures, not only in biomedical specimens but also in inorganic samples.</description><subject>Beams (radiation)</subject><subject>Biomedical optical imaging</subject><subject>Biomedical research</subject><subject>Breast tissue</subject><subject>Charge coupled devices</subject><subject>Humans</subject><subject>Image contrast</subject><subject>Imaging</subject><subject>Mice</subject><subject>Optical filters</subject><subject>Optical imaging</subject><subject>Projection</subject><subject>Spatial resolution</subject><subject>Strontium</subject><subject>Synchrotrons</subject><subject>X-rays</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNp9kT1vFDEQhq0IJI5ATZHGEhJKir3z-Gu9JTpBEimCgkOiW3n3ZrmNzvbG9gYdNT8cny5FREE1Gs3zztdLyDtgSwDWrDZfvi05Y3xpmDAgz8gClDIVqNq8IAvGwFSNbJpX5HVK9yWViqkF-bMObpozbqkb-xhycOFntNPuQC9XadpTN6_Wmyv6a8w7OnsXfOh3MTibx99Fkw7-mOYYPP1RRXtIdAiR9tb3GMOc6G521tMuok2Z5jGlGan1ZVgpIn3EmLGL9g15Odh9wrdP8Zx8__xps76p7r5e364_3lW9UJAroQYutOAdiHoLXFqUQivBUaLWPW_0tjMAncahl8gHxo2WQkBtBTPbhqE4Jx9OfacYHmZMuXVj6nG_tx7LQi03HEBJXsDL_4KgaxC8rpUp6Pt_0PswR1_OaKH8XBvTiKZQqxNVfpxSxKGd4uhsPBSoPdrXFvvao33tyb6iuDgpRkR8RktdlhR_AX5Flt0</recordid><startdate>20021001</startdate><enddate>20021001</enddate><creator>Jung, Haijo</creator><creator>Kim, Hee-Joung</creator><creator>Hong, Soonil</creator><creator>Hong, Jin-O</creator><creator>Jeong, Ha-Kyu</creator><creator>Je, Jung Ho</creator><creator>Kim, Bo-Ra</creator><creator>Yoo, Hyung-Sik</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QL</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7T7</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M7N</scope><scope>P64</scope></search><sort><creationdate>20021001</creationdate><title>Computed microtomography (/spl mu/CT) with unmonochromatized synchrotron X-rays for cancerous human breast tissue and mouse vertebra</title><author>Jung, Haijo ; Kim, Hee-Joung ; Hong, Soonil ; Hong, Jin-O ; Jeong, Ha-Kyu ; Je, Jung Ho ; Kim, Bo-Ra ; Yoo, Hyung-Sik</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c351t-35f23632b137d124ae436532e4e66c296db811b6efc4e2f028643317a308d90e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Beams (radiation)</topic><topic>Biomedical optical imaging</topic><topic>Biomedical research</topic><topic>Breast tissue</topic><topic>Charge coupled devices</topic><topic>Humans</topic><topic>Image contrast</topic><topic>Imaging</topic><topic>Mice</topic><topic>Optical filters</topic><topic>Optical imaging</topic><topic>Projection</topic><topic>Spatial resolution</topic><topic>Strontium</topic><topic>Synchrotrons</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jung, Haijo</creatorcontrib><creatorcontrib>Kim, Hee-Joung</creatorcontrib><creatorcontrib>Hong, Soonil</creatorcontrib><creatorcontrib>Hong, Jin-O</creatorcontrib><creatorcontrib>Jeong, Ha-Kyu</creatorcontrib><creatorcontrib>Je, Jung Ho</creatorcontrib><creatorcontrib>Kim, Bo-Ra</creatorcontrib><creatorcontrib>Yoo, Hyung-Sik</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Jung, Haijo</au><au>Kim, Hee-Joung</au><au>Hong, Soonil</au><au>Hong, Jin-O</au><au>Jeong, Ha-Kyu</au><au>Je, Jung Ho</au><au>Kim, Bo-Ra</au><au>Yoo, Hyung-Sik</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computed microtomography (/spl mu/CT) with unmonochromatized synchrotron X-rays for cancerous human breast tissue and mouse vertebra</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>2002-10-01</date><risdate>2002</risdate><volume>49</volume><issue>5</issue><spage>2262</spage><epage>2267</epage><pages>2262-2267</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>The use of X-ray computed microtomography (PCT) has increased in biomedical research and industrial applications. The inherited high quality of synchrotron radiation (SR) X-rays including high flux, collimation, and coherence, has been used recently to produce radiographic images with high spatial resolution and contrast. A simple and stable imaging system using an unmonochromatized SR source based on the principle of phase contrast X-ray imaging consists of a charge-coupled device (CCD) detector coupled with an optical lens system at the Pohang Light Source (PLS) 5C1 beamline. The spatial resolution of the imaging system was determined using the modulation transfer function (MTF), which was measured by step-by step calculations obtained from sharp edge images. Projection image data were obtained at 250 steps over 180 degrees of rotation with an acquisition time, depending on the imaged object materials, of 30 to 150 ms per projection image. The tomographic images were reconstructed using a simple filtered backprojection algorithm to reconstruct two-dimensional (2-D) images using projection data which may include characteristics of beam collimation and phase contrast. Although the use of a monochromatic X-ray beam has previously demonstrated to provide high resolution and enhanced contrast, our approach uses an unmonochromatized SR X-ray beam and shows similar image capability, without the needs for sophisticated X-ray optics, in an exposure time which is significantly less, by two orders of magnitude, than that for the monochromatic SR system. The current PLS 5C1 SR imaging system can produce projection images at a spatial resolution of 8.3 /spl mu/m over a field of view of about 5 mm at an exposure time of 30 ms per projection image for 1.5 /spl times/ optical magnification. This study presents the results of SR /spl mu/CT images of cancerous human breast tissue containing microcalcifications, mouse lumbar vertebra, and mouse coccygeal vertebra. The unmonochromatized SR /spl mu/CT imaging system provides an effective means of evaluating microstructures, not only in biomedical specimens but also in inorganic samples.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TNS.2002.803814</doi><tpages>6</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 2002-10, Vol.49 (5), p.2262-2267
issn 0018-9499
1558-1578
language eng
recordid cdi_proquest_journals_1018688939
source IEEE Electronic Library (IEL)
subjects Beams (radiation)
Biomedical optical imaging
Biomedical research
Breast tissue
Charge coupled devices
Humans
Image contrast
Imaging
Mice
Optical filters
Optical imaging
Projection
Spatial resolution
Strontium
Synchrotrons
X-rays
title Computed microtomography (/spl mu/CT) with unmonochromatized synchrotron X-rays for cancerous human breast tissue and mouse vertebra
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T06%3A36%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computed%20microtomography%20(/spl%20mu/CT)%20with%20unmonochromatized%20synchrotron%20X-rays%20for%20cancerous%20human%20breast%20tissue%20and%20mouse%20vertebra&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Jung,%20Haijo&rft.date=2002-10-01&rft.volume=49&rft.issue=5&rft.spage=2262&rft.epage=2267&rft.pages=2262-2267&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.2002.803814&rft_dat=%3Cproquest_RIE%3E1671327758%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1018688939&rft_id=info:pmid/&rft_ieee_id=1046821&rfr_iscdi=true