Measurement properties of cervical joint position error in people with and without chronic neck pain

People with chronic neck pain (CNP) often present with impaired neck proprioception. The most widely used clinical test for assessing neck proprioception is cervical joint position sense which measures joint position error (JPE). This clinical test is typically performed using a laser pointer to exa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2023-10, Vol.18 (10), p.e0292798-e0292798
Hauptverfasser: AlDahas, Ahmad, Devecchi, Valter, Deane, Janet A, Falla, Deborah
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:People with chronic neck pain (CNP) often present with impaired neck proprioception. The most widely used clinical test for assessing neck proprioception is cervical joint position sense which measures joint position error (JPE). This clinical test is typically performed using a laser pointer to examine the accuracy of returning to a neutral head position (NHP) or target head position (THP) following active neck movements. The aim of this study was to determine the measurement properties of JPE using a laser pointer when tested in people with and without CNP under a variety of different testing conditions (i.e., different movement directions, sitting versus standing, NHP versus THP). Forty-three participants (23 asymptomatic and 20 with CNP) underwent neck proprioception testing, returning to a NHP and THP in both sitting and standing positions (six trials for each test). A laser pointer was secured on the participant's forehead and inertial measurement unit (IMU) sensors were placed beneath the laser pointer and at the level of the spinous process of the seventh cervical vertebra. Both the absolute and the constant JPE were assessed. For the asymptomatic participants, good reliability (ICC: 0.79) was found only for right rotation of the THP task in sitting. In standing, good reliability (ICC: 0.77) was only found in flexion for the THP task. In standing, good reliability (ICC: 0.77) was only found for right rotation of the THP for the absolute JPE and left rotation (ICC: 0.85) for the constant error of the NHP task. In those with CNP, when tested in sitting, good reliability was found for flexion (ICC: 0.8) for the absolute JPE and good reliability (ICC range: 0.8-0.84) was found for flexion, extension, and right rotation for the constant JPE. In standing, good reliability (ICC range: 0.81-0.88) was found for flexion, and rotation for the absolute JPE. The constant JPE showed good reliability (ICC: 0.85) for right rotation and excellent reliability (ICC: 0.93) for flexion. Validity was weak to strong (r range: 0.26-0.83) and moderate to very strong (r range: 0.47-0.93) for absolute and constant error respectively, when tested in sitting. In standing, the validity was weak to very strong (0.38-0.96) for the absolute JPE and moderate to very strong (r range: 0.54-0.92) for the constant JPE. The reliability of the measure of JPE when tested in sitting and standing in both groups showed good reliability, but not for all movements. The results of the current s
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0292798