Different in-plane resolutions have been used for carotid 3T MRI. We compared the reproducibility, as well as the within- and between reader variability of high and routinely used spatial resolution in scans of patients with atherosclerotic carotid artery disease. Since no consensus exists about the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2015-07, Vol.10 (7), p.e0130878-e0130878
Hauptverfasser: van Wijk, Diederik F, Strang, Aart C, Duivenvoorden, Raphael, Enklaar, Dirk-Jan F, Zwinderman, Aeilko H, van der Geest, Rob J, Kastelein, John J P, de Groot, Eric, Stroes, Erik S G, Nederveen, Aart J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Different in-plane resolutions have been used for carotid 3T MRI. We compared the reproducibility, as well as the within- and between reader variability of high and routinely used spatial resolution in scans of patients with atherosclerotic carotid artery disease. Since no consensus exists about the optimal segmentation method, we analysed all imaging data using two different segmentation methods. In 31 patient with carotid atherosclerosis a high (0.25 × 0.25 mm2; HR) and routinely used (0.50 × 0.50 mm2; LR) spatial resolution carotid MRI scan were performed within one month. A fully blinded closed and a simultaneously open segmentation were used to quantify the lipid rich necrotic core (LRNC), calcified and loose matrix (LM) plaque area and the fibrous cap (FC) thickness. No significant differences were observed between scan-rescan reproducibility for HR versus LR measurements, nor did we find any significant difference between the within-reader and between-reader reproducibility. The same applies for differences between the open and closed reads. All intraclass correlation coefficients between scans and rescans for the LRNC, calcified and LM plaque area, as well as the FC thickness measurements with the open segmentation method were excellent (all above 0.75). Increasing the spatial resolution at the expense of the contrast-to-noise ratio does not improve carotid plaque component scan-rescan reproducibility in patients with atherosclerotic carotid disease, nor does using a different segmentation method.