Impedance of the Residential Power-Distribution Circuit
This paper presents measurements and analysis of the impedance of residential power-distribution circuits at frequencies from 5 to 20 kHz. These frequencies are used by systems such as distribution-line carriers which use the power distribution circuit as a communications medium. Residential impedan...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on electromagnetic compatibility 1985-02, Vol.EMC-27 (1), p.6-12 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 12 |
---|---|
container_issue | 1 |
container_start_page | 6 |
container_title | IEEE transactions on electromagnetic compatibility |
container_volume | EMC-27 |
creator | Vines, Roger M. Trussell, H. Joel Shuey, Kenneth C. O'Neal, J. B. |
description | This paper presents measurements and analysis of the impedance of residential power-distribution circuits at frequencies from 5 to 20 kHz. These frequencies are used by systems such as distribution-line carriers which use the power distribution circuit as a communications medium. Residential impedances are determined by the distribution transformer secondary windings, entrance cables, house wiring, and electrical loads. Impedance measurements of these components and measurements at four residences are presented. |
doi_str_mv | 10.1109/TEMC.1985.304239 |
format | Article |
fullrecord | <record><control><sourceid>pascalfrancis_RIE</sourceid><recordid>TN_cdi_pascalfrancis_primary_8483961</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4091771</ieee_id><sourcerecordid>8483961</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-39ea3cd208158f555c1e1bfbd8db44fbf0feada28f2db7b7a68fe429697ee67f3</originalsourceid><addsrcrecordid>eNo9j01LAzEURYMoWKt7wc0s3E7NmySTZClj1UJFkQruhny8YKTtlGSK-O-dMtLV4_LuuXAIuQY6A6D6bjV_aWaglZgxyiumT8gEhFAlKPl5SiaUgio1k-KcXOT8PUQuKjYhcrHZoTdbh0UXiv4Li3fM0eO2j2ZdvHU_mMqHmPsU7b6P3bZoYnL72F-Ss2DWGa_-75R8PM5XzXO5fH1aNPfL0jFR9yXTaJjzFVUgVBBCOECwwXrlLefBBhrQeFOpUHkrrTS1CsgrXWuJWMvApoSOuy51OScM7S7FjUm_LdD2IN4exNuDeDuKD8jtiOxMdmYd0mAX85FTXDFdw1C7GWsREY9fTjVICewPF25iNA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Impedance of the Residential Power-Distribution Circuit</title><source>IEEE Electronic Library (IEL)</source><creator>Vines, Roger M. ; Trussell, H. Joel ; Shuey, Kenneth C. ; O'Neal, J. B.</creator><creatorcontrib>Vines, Roger M. ; Trussell, H. Joel ; Shuey, Kenneth C. ; O'Neal, J. B.</creatorcontrib><description>This paper presents measurements and analysis of the impedance of residential power-distribution circuits at frequencies from 5 to 20 kHz. These frequencies are used by systems such as distribution-line carriers which use the power distribution circuit as a communications medium. Residential impedances are determined by the distribution transformer secondary windings, entrance cables, house wiring, and electrical loads. Impedance measurements of these components and measurements at four residences are presented.</description><identifier>ISSN: 0018-9375</identifier><identifier>EISSN: 1558-187X</identifier><identifier>DOI: 10.1109/TEMC.1985.304239</identifier><identifier>CODEN: IEMCAE</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>5-100 kHz ; analysis ; Applied sciences ; Exact sciences and technology ; Frequency measurement ; Impedance ; Impedance measurement ; Instrument transformers ; measurement ; Power measurement ; Powerline impedance ; Systems, networks and services of telecommunications ; Telecommunications ; Telecommunications and information theory ; Transmission and modulation (techniques and equipments) ; Voltage measurement ; Wires</subject><ispartof>IEEE transactions on electromagnetic compatibility, 1985-02, Vol.EMC-27 (1), p.6-12</ispartof><rights>1986 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-39ea3cd208158f555c1e1bfbd8db44fbf0feada28f2db7b7a68fe429697ee67f3</citedby><cites>FETCH-LOGICAL-c356t-39ea3cd208158f555c1e1bfbd8db44fbf0feada28f2db7b7a68fe429697ee67f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4091771$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4091771$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=8483961$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Vines, Roger M.</creatorcontrib><creatorcontrib>Trussell, H. Joel</creatorcontrib><creatorcontrib>Shuey, Kenneth C.</creatorcontrib><creatorcontrib>O'Neal, J. B.</creatorcontrib><title>Impedance of the Residential Power-Distribution Circuit</title><title>IEEE transactions on electromagnetic compatibility</title><addtitle>TEMC</addtitle><description>This paper presents measurements and analysis of the impedance of residential power-distribution circuits at frequencies from 5 to 20 kHz. These frequencies are used by systems such as distribution-line carriers which use the power distribution circuit as a communications medium. Residential impedances are determined by the distribution transformer secondary windings, entrance cables, house wiring, and electrical loads. Impedance measurements of these components and measurements at four residences are presented.</description><subject>5-100 kHz</subject><subject>analysis</subject><subject>Applied sciences</subject><subject>Exact sciences and technology</subject><subject>Frequency measurement</subject><subject>Impedance</subject><subject>Impedance measurement</subject><subject>Instrument transformers</subject><subject>measurement</subject><subject>Power measurement</subject><subject>Powerline impedance</subject><subject>Systems, networks and services of telecommunications</subject><subject>Telecommunications</subject><subject>Telecommunications and information theory</subject><subject>Transmission and modulation (techniques and equipments)</subject><subject>Voltage measurement</subject><subject>Wires</subject><issn>0018-9375</issn><issn>1558-187X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1985</creationdate><recordtype>article</recordtype><recordid>eNo9j01LAzEURYMoWKt7wc0s3E7NmySTZClj1UJFkQruhny8YKTtlGSK-O-dMtLV4_LuuXAIuQY6A6D6bjV_aWaglZgxyiumT8gEhFAlKPl5SiaUgio1k-KcXOT8PUQuKjYhcrHZoTdbh0UXiv4Li3fM0eO2j2ZdvHU_mMqHmPsU7b6P3bZoYnL72F-Ss2DWGa_-75R8PM5XzXO5fH1aNPfL0jFR9yXTaJjzFVUgVBBCOECwwXrlLefBBhrQeFOpUHkrrTS1CsgrXWuJWMvApoSOuy51OScM7S7FjUm_LdD2IN4exNuDeDuKD8jtiOxMdmYd0mAX85FTXDFdw1C7GWsREY9fTjVICewPF25iNA</recordid><startdate>198502</startdate><enddate>198502</enddate><creator>Vines, Roger M.</creator><creator>Trussell, H. Joel</creator><creator>Shuey, Kenneth C.</creator><creator>O'Neal, J. B.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>198502</creationdate><title>Impedance of the Residential Power-Distribution Circuit</title><author>Vines, Roger M. ; Trussell, H. Joel ; Shuey, Kenneth C. ; O'Neal, J. B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-39ea3cd208158f555c1e1bfbd8db44fbf0feada28f2db7b7a68fe429697ee67f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1985</creationdate><topic>5-100 kHz</topic><topic>analysis</topic><topic>Applied sciences</topic><topic>Exact sciences and technology</topic><topic>Frequency measurement</topic><topic>Impedance</topic><topic>Impedance measurement</topic><topic>Instrument transformers</topic><topic>measurement</topic><topic>Power measurement</topic><topic>Powerline impedance</topic><topic>Systems, networks and services of telecommunications</topic><topic>Telecommunications</topic><topic>Telecommunications and information theory</topic><topic>Transmission and modulation (techniques and equipments)</topic><topic>Voltage measurement</topic><topic>Wires</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vines, Roger M.</creatorcontrib><creatorcontrib>Trussell, H. Joel</creatorcontrib><creatorcontrib>Shuey, Kenneth C.</creatorcontrib><creatorcontrib>O'Neal, J. B.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>IEEE transactions on electromagnetic compatibility</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Vines, Roger M.</au><au>Trussell, H. Joel</au><au>Shuey, Kenneth C.</au><au>O'Neal, J. B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impedance of the Residential Power-Distribution Circuit</atitle><jtitle>IEEE transactions on electromagnetic compatibility</jtitle><stitle>TEMC</stitle><date>1985-02</date><risdate>1985</risdate><volume>EMC-27</volume><issue>1</issue><spage>6</spage><epage>12</epage><pages>6-12</pages><issn>0018-9375</issn><eissn>1558-187X</eissn><coden>IEMCAE</coden><abstract>This paper presents measurements and analysis of the impedance of residential power-distribution circuits at frequencies from 5 to 20 kHz. These frequencies are used by systems such as distribution-line carriers which use the power distribution circuit as a communications medium. Residential impedances are determined by the distribution transformer secondary windings, entrance cables, house wiring, and electrical loads. Impedance measurements of these components and measurements at four residences are presented.</abstract><cop>New York, NY</cop><pub>IEEE</pub><doi>10.1109/TEMC.1985.304239</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9375 |
ispartof | IEEE transactions on electromagnetic compatibility, 1985-02, Vol.EMC-27 (1), p.6-12 |
issn | 0018-9375 1558-187X |
language | eng |
recordid | cdi_pascalfrancis_primary_8483961 |
source | IEEE Electronic Library (IEL) |
subjects | 5-100 kHz analysis Applied sciences Exact sciences and technology Frequency measurement Impedance Impedance measurement Instrument transformers measurement Power measurement Powerline impedance Systems, networks and services of telecommunications Telecommunications Telecommunications and information theory Transmission and modulation (techniques and equipments) Voltage measurement Wires |
title | Impedance of the Residential Power-Distribution Circuit |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T11%3A08%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pascalfrancis_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impedance%20of%20the%20Residential%20Power-Distribution%20Circuit&rft.jtitle=IEEE%20transactions%20on%20electromagnetic%20compatibility&rft.au=Vines,%20Roger%20M.&rft.date=1985-02&rft.volume=EMC-27&rft.issue=1&rft.spage=6&rft.epage=12&rft.pages=6-12&rft.issn=0018-9375&rft.eissn=1558-187X&rft.coden=IEMCAE&rft_id=info:doi/10.1109/TEMC.1985.304239&rft_dat=%3Cpascalfrancis_RIE%3E8483961%3C/pascalfrancis_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4091771&rfr_iscdi=true |