Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes.: Application for the determination of ascorbic acid

A screen printed carbon electrode (SPCE) impregnated with the electrocatalyst 2,6-dichlorophenolindophenol lanthanum salt ([DCPI] 3La)was constructed. Using cyclic voltammetry the electrochemical behaviour of SPCE, -SPEs and their catalytic effect towards ascorbic acid was investigated. A synthesis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2000-10, Vol.423 (1), p.107-114
Hauptverfasser: Florou, Ageliki B., Prodromidis, Mamas I., Tzouwara-Karayanni, Stella M., Karayannis, Miltiades I.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 114
container_issue 1
container_start_page 107
container_title Analytica chimica acta
container_volume 423
creator Florou, Ageliki B.
Prodromidis, Mamas I.
Tzouwara-Karayanni, Stella M.
Karayannis, Miltiades I.
description A screen printed carbon electrode (SPCE) impregnated with the electrocatalyst 2,6-dichlorophenolindophenol lanthanum salt ([DCPI] 3La)was constructed. Using cyclic voltammetry the electrochemical behaviour of SPCE, -SPEs and their catalytic effect towards ascorbic acid was investigated. A synthesis protocol ([DCPI] 3La) and some identification studies are given. The fabrication of (SPE) using a mixture of 5% (w/w) [DCPI] 3-La/graphite powder in 1 and 2% (w/v) ethyl cellulose in 2-butoxyethylacetate is also described. Constant potential amperometry in stirred solutions was used for the determination of ascorbic acid in beverages and pharmaceuticals potential of +0.1 V versus Ag/AgCl, at pH 7.25 was employed. This technique was also used to assess the reproducibility of the electrode manufacture. Interference of various compounds was also studied. Good correlation with the official titrimetric method was attained. Calibration graphs were linear over the range 0.01–1 mM ascorbic acid and the RSD was 1.8% ( n=9) for 0.6 mM ascorbic acid. Recovery ranged from 91 to 103%. The [DCPI] 3-La-SPE showed very good storage and operational stability.
doi_str_mv 10.1016/S0003-2670(00)01081-3
format Article
fullrecord <record><control><sourceid>elsevier_pasca</sourceid><recordid>TN_cdi_pascalfrancis_primary_808182</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267000010813</els_id><sourcerecordid>S0003267000010813</sourcerecordid><originalsourceid>FETCH-LOGICAL-e237t-5c014acc403fcda1fca4ed0858ef23ffc39283141c54317d818725c6a53775913</originalsourceid><addsrcrecordid>eNo9UdtqGzEQFaWFOm4_oSDISwPdVJdd76YvIZg4KRj60ORZKKMRq6CVFkkO-Kvyi5VjpzAwFw5zzswh5Btnl5zx1c-_jDHZiFXPvjN2wTgbeCM_kAUfetm0UrQfyeI_5DM5y_m5toKzdkFeN_opOdDFxUB1MPQl-qKnCUud0lx2Zk-jpV6HMuqwm6j4sWqMg9HHFOcRQ_QumFNFYcSpLvN-T6donHVoaIaEGOicXCi1RY9QUjSYL3_Rm3n27-Q2JlpGpAYLpsmF47Ry6wwxPVU1Gpz5Qj5Z7TN-PeUledzcPqzvm-2fu9_rm22DQval6YDxVgO0TFowmlvQLRo2dANaIa0FeSUGyVsOXSt5b4b6K9HBSney77srLpfk_Lh3rvTa26QDuKzqFZNOezXUHw-ioq6PKKxSXhwmlcFhADQu1TOViU5xpg4uqTeX1MECxWocXFJS_gMEKIpx</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes.: Application for the determination of ascorbic acid</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Florou, Ageliki B. ; Prodromidis, Mamas I. ; Tzouwara-Karayanni, Stella M. ; Karayannis, Miltiades I.</creator><creatorcontrib>Florou, Ageliki B. ; Prodromidis, Mamas I. ; Tzouwara-Karayanni, Stella M. ; Karayannis, Miltiades I.</creatorcontrib><description>A screen printed carbon electrode (SPCE) impregnated with the electrocatalyst 2,6-dichlorophenolindophenol lanthanum salt ([DCPI] 3La)was constructed. Using cyclic voltammetry the electrochemical behaviour of SPCE, -SPEs and their catalytic effect towards ascorbic acid was investigated. A synthesis protocol ([DCPI] 3La) and some identification studies are given. The fabrication of (SPE) using a mixture of 5% (w/w) [DCPI] 3-La/graphite powder in 1 and 2% (w/v) ethyl cellulose in 2-butoxyethylacetate is also described. Constant potential amperometry in stirred solutions was used for the determination of ascorbic acid in beverages and pharmaceuticals potential of +0.1 V versus Ag/AgCl, at pH 7.25 was employed. This technique was also used to assess the reproducibility of the electrode manufacture. Interference of various compounds was also studied. Good correlation with the official titrimetric method was attained. Calibration graphs were linear over the range 0.01–1 mM ascorbic acid and the RSD was 1.8% ( n=9) for 0.6 mM ascorbic acid. Recovery ranged from 91 to 103%. The [DCPI] 3-La-SPE showed very good storage and operational stability.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/S0003-2670(00)01081-3</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>[DCPI] 3-La-SPE ; Analytical chemistry ; Beverages ; Chemistry ; Electrochemical determination of ascorbic acid ; Electrochemistry ; Electrodes: preparations and properties ; Exact sciences and technology ; General and physical chemistry ; General, instrumentation ; Other electrodes ; Pharmaceuticals ; Screen printed electrodes</subject><ispartof>Analytica chimica acta, 2000-10, Vol.423 (1), p.107-114</ispartof><rights>2000 Elsevier Science B.V.</rights><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S0003-2670(00)01081-3$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=808182$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Florou, Ageliki B.</creatorcontrib><creatorcontrib>Prodromidis, Mamas I.</creatorcontrib><creatorcontrib>Tzouwara-Karayanni, Stella M.</creatorcontrib><creatorcontrib>Karayannis, Miltiades I.</creatorcontrib><title>Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes.: Application for the determination of ascorbic acid</title><title>Analytica chimica acta</title><description>A screen printed carbon electrode (SPCE) impregnated with the electrocatalyst 2,6-dichlorophenolindophenol lanthanum salt ([DCPI] 3La)was constructed. Using cyclic voltammetry the electrochemical behaviour of SPCE, -SPEs and their catalytic effect towards ascorbic acid was investigated. A synthesis protocol ([DCPI] 3La) and some identification studies are given. The fabrication of (SPE) using a mixture of 5% (w/w) [DCPI] 3-La/graphite powder in 1 and 2% (w/v) ethyl cellulose in 2-butoxyethylacetate is also described. Constant potential amperometry in stirred solutions was used for the determination of ascorbic acid in beverages and pharmaceuticals potential of +0.1 V versus Ag/AgCl, at pH 7.25 was employed. This technique was also used to assess the reproducibility of the electrode manufacture. Interference of various compounds was also studied. Good correlation with the official titrimetric method was attained. Calibration graphs were linear over the range 0.01–1 mM ascorbic acid and the RSD was 1.8% ( n=9) for 0.6 mM ascorbic acid. Recovery ranged from 91 to 103%. The [DCPI] 3-La-SPE showed very good storage and operational stability.</description><subject>[DCPI] 3-La-SPE</subject><subject>Analytical chemistry</subject><subject>Beverages</subject><subject>Chemistry</subject><subject>Electrochemical determination of ascorbic acid</subject><subject>Electrochemistry</subject><subject>Electrodes: preparations and properties</subject><subject>Exact sciences and technology</subject><subject>General and physical chemistry</subject><subject>General, instrumentation</subject><subject>Other electrodes</subject><subject>Pharmaceuticals</subject><subject>Screen printed electrodes</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNo9UdtqGzEQFaWFOm4_oSDISwPdVJdd76YvIZg4KRj60ORZKKMRq6CVFkkO-Kvyi5VjpzAwFw5zzswh5Btnl5zx1c-_jDHZiFXPvjN2wTgbeCM_kAUfetm0UrQfyeI_5DM5y_m5toKzdkFeN_opOdDFxUB1MPQl-qKnCUud0lx2Zk-jpV6HMuqwm6j4sWqMg9HHFOcRQ_QumFNFYcSpLvN-T6donHVoaIaEGOicXCi1RY9QUjSYL3_Rm3n27-Q2JlpGpAYLpsmF47Ry6wwxPVU1Gpz5Qj5Z7TN-PeUledzcPqzvm-2fu9_rm22DQval6YDxVgO0TFowmlvQLRo2dANaIa0FeSUGyVsOXSt5b4b6K9HBSney77srLpfk_Lh3rvTa26QDuKzqFZNOezXUHw-ioq6PKKxSXhwmlcFhADQu1TOViU5xpg4uqTeX1MECxWocXFJS_gMEKIpx</recordid><startdate>20001020</startdate><enddate>20001020</enddate><creator>Florou, Ageliki B.</creator><creator>Prodromidis, Mamas I.</creator><creator>Tzouwara-Karayanni, Stella M.</creator><creator>Karayannis, Miltiades I.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope></search><sort><creationdate>20001020</creationdate><title>Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes.: Application for the determination of ascorbic acid</title><author>Florou, Ageliki B. ; Prodromidis, Mamas I. ; Tzouwara-Karayanni, Stella M. ; Karayannis, Miltiades I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-e237t-5c014acc403fcda1fca4ed0858ef23ffc39283141c54317d818725c6a53775913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>[DCPI] 3-La-SPE</topic><topic>Analytical chemistry</topic><topic>Beverages</topic><topic>Chemistry</topic><topic>Electrochemical determination of ascorbic acid</topic><topic>Electrochemistry</topic><topic>Electrodes: preparations and properties</topic><topic>Exact sciences and technology</topic><topic>General and physical chemistry</topic><topic>General, instrumentation</topic><topic>Other electrodes</topic><topic>Pharmaceuticals</topic><topic>Screen printed electrodes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Florou, Ageliki B.</creatorcontrib><creatorcontrib>Prodromidis, Mamas I.</creatorcontrib><creatorcontrib>Tzouwara-Karayanni, Stella M.</creatorcontrib><creatorcontrib>Karayannis, Miltiades I.</creatorcontrib><collection>Pascal-Francis</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Florou, Ageliki B.</au><au>Prodromidis, Mamas I.</au><au>Tzouwara-Karayanni, Stella M.</au><au>Karayannis, Miltiades I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes.: Application for the determination of ascorbic acid</atitle><jtitle>Analytica chimica acta</jtitle><date>2000-10-20</date><risdate>2000</risdate><volume>423</volume><issue>1</issue><spage>107</spage><epage>114</epage><pages>107-114</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>A screen printed carbon electrode (SPCE) impregnated with the electrocatalyst 2,6-dichlorophenolindophenol lanthanum salt ([DCPI] 3La)was constructed. Using cyclic voltammetry the electrochemical behaviour of SPCE, -SPEs and their catalytic effect towards ascorbic acid was investigated. A synthesis protocol ([DCPI] 3La) and some identification studies are given. The fabrication of (SPE) using a mixture of 5% (w/w) [DCPI] 3-La/graphite powder in 1 and 2% (w/v) ethyl cellulose in 2-butoxyethylacetate is also described. Constant potential amperometry in stirred solutions was used for the determination of ascorbic acid in beverages and pharmaceuticals potential of +0.1 V versus Ag/AgCl, at pH 7.25 was employed. This technique was also used to assess the reproducibility of the electrode manufacture. Interference of various compounds was also studied. Good correlation with the official titrimetric method was attained. Calibration graphs were linear over the range 0.01–1 mM ascorbic acid and the RSD was 1.8% ( n=9) for 0.6 mM ascorbic acid. Recovery ranged from 91 to 103%. The [DCPI] 3-La-SPE showed very good storage and operational stability.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/S0003-2670(00)01081-3</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2000-10, Vol.423 (1), p.107-114
issn 0003-2670
1873-4324
language eng
recordid cdi_pascalfrancis_primary_808182
source Elsevier ScienceDirect Journals Complete
subjects [DCPI] 3-La-SPE
Analytical chemistry
Beverages
Chemistry
Electrochemical determination of ascorbic acid
Electrochemistry
Electrodes: preparations and properties
Exact sciences and technology
General and physical chemistry
General, instrumentation
Other electrodes
Pharmaceuticals
Screen printed electrodes
title Fabrication and voltammetric study of lanthanum 2,6-dichlorophenolindophenol chemically modified screen printed electrodes.: Application for the determination of ascorbic acid
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T12%3A17%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_pasca&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fabrication%20and%20voltammetric%20study%20of%20lanthanum%202,6-dichlorophenolindophenol%20chemically%20modified%20screen%20printed%20electrodes.:%20Application%20for%20the%20determination%20of%20ascorbic%20acid&rft.jtitle=Analytica%20chimica%20acta&rft.au=Florou,%20Ageliki%20B.&rft.date=2000-10-20&rft.volume=423&rft.issue=1&rft.spage=107&rft.epage=114&rft.pages=107-114&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/S0003-2670(00)01081-3&rft_dat=%3Celsevier_pasca%3ES0003267000010813%3C/elsevier_pasca%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0003267000010813&rfr_iscdi=true