Reduction of susceptibility artifact in gradient-echo imaging

A new technique with which susceptibility artifact in gradient‐echo imaging can be reduced substantially by use of a tailored RF pulse is described. The proposed technique can ideally be applied to the case where high local magnetic field inhomogeneity is dominated by the susceptibility. The signal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in medicine 1992-01, Vol.23 (1), p.193-200
Hauptverfasser: Cho, Z. H., Ro, Y. M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 200
container_issue 1
container_start_page 193
container_title Magnetic resonance in medicine
container_volume 23
creator Cho, Z. H.
Ro, Y. M.
description A new technique with which susceptibility artifact in gradient‐echo imaging can be reduced substantially by use of a tailored RF pulse is described. The proposed technique can ideally be applied to the case where high local magnetic field inhomogeneity is dominated by the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method is also proposed. The description of the tailored RF pulse and its proposed application are given and experimental results obtained using a human volunteer with a 2.0‐T KAIS NMR system are presented. © 1992 Academic Press, Inc.
doi_str_mv 10.1002/mrm.1910230120
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_pascalfrancis_primary_5134344</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72795818</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4730-b8dd7312915815b2282f38124f0bd1747240d71434006c45b76e1e1d401ba9653</originalsourceid><addsrcrecordid>eNqFkDtPHDEUha2ICDaQNl2kKRDdbO71Yz0uKAiChfCIhBJBZ3k8nsXJPDb2jJL99ziaFYiK6hbnO-ceHUI-IcwRgH5pQztHhUAZIIV3ZIaC0pwKxXfIDCSHnKHie-RDjL8AQCnJd8kuSsZRqhk5vnPVaAffd1lfZ3GM1q0HX_rGD5vMhMHXxg6Z77JVMJV33ZA7-9hnvjUr360OyPvaNNF93N598vP87MfpRX79fXl5enKdWy4Z5GVRVZIhVSgKFCWlBa1ZgZTXUFYouaQcKomccYCF5aKUC4cOKw5YGrUQbJ8cTbnr0P8ZXRx061PTpjGd68eoJZUqRRcJnE-gDX2MwdV6HVLXsNEI-v9eOu2lX_ZKhs_b5LFsXfWCTwMl_XCrm2hNUwfTWR-fMYEsteYJUxP21zdu88ZTfXN386pCPnl9HNy_Z68Jv_VCMin0_e1SfxUX598erq70kj0BpL-QfA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72795818</pqid></control><display><type>article</type><title>Reduction of susceptibility artifact in gradient-echo imaging</title><source>MEDLINE</source><source>Wiley Online Library Journals</source><creator>Cho, Z. H. ; Ro, Y. M.</creator><creatorcontrib>Cho, Z. H. ; Ro, Y. M.</creatorcontrib><description>A new technique with which susceptibility artifact in gradient‐echo imaging can be reduced substantially by use of a tailored RF pulse is described. The proposed technique can ideally be applied to the case where high local magnetic field inhomogeneity is dominated by the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method is also proposed. The description of the tailored RF pulse and its proposed application are given and experimental results obtained using a human volunteer with a 2.0‐T KAIS NMR system are presented. © 1992 Academic Press, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.1910230120</identifier><identifier>PMID: 1734179</identifier><identifier>CODEN: MRMEEN</identifier><language>eng</language><publisher>Baltimore: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Biological and medical sciences ; Humans ; Image Enhancement - methods ; Investigative techniques, diagnostic techniques (general aspects) ; Magnetic Resonance Imaging - methods ; Medical sciences ; Miscellaneous. Technology ; Models, Theoretical ; Nasal Cavity - anatomy &amp; histology ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Signal Processing, Computer-Assisted</subject><ispartof>Magnetic resonance in medicine, 1992-01, Vol.23 (1), p.193-200</ispartof><rights>Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company</rights><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4730-b8dd7312915815b2282f38124f0bd1747240d71434006c45b76e1e1d401ba9653</citedby><cites>FETCH-LOGICAL-c4730-b8dd7312915815b2282f38124f0bd1747240d71434006c45b76e1e1d401ba9653</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmrm.1910230120$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmrm.1910230120$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,4024,27923,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5134344$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1734179$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cho, Z. H.</creatorcontrib><creatorcontrib>Ro, Y. M.</creatorcontrib><title>Reduction of susceptibility artifact in gradient-echo imaging</title><title>Magnetic resonance in medicine</title><addtitle>Magn. Reson. Med</addtitle><description>A new technique with which susceptibility artifact in gradient‐echo imaging can be reduced substantially by use of a tailored RF pulse is described. The proposed technique can ideally be applied to the case where high local magnetic field inhomogeneity is dominated by the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method is also proposed. The description of the tailored RF pulse and its proposed application are given and experimental results obtained using a human volunteer with a 2.0‐T KAIS NMR system are presented. © 1992 Academic Press, Inc.</description><subject>Biological and medical sciences</subject><subject>Humans</subject><subject>Image Enhancement - methods</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Medical sciences</subject><subject>Miscellaneous. Technology</subject><subject>Models, Theoretical</subject><subject>Nasal Cavity - anatomy &amp; histology</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Signal Processing, Computer-Assisted</subject><issn>0740-3194</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkDtPHDEUha2ICDaQNl2kKRDdbO71Yz0uKAiChfCIhBJBZ3k8nsXJPDb2jJL99ziaFYiK6hbnO-ceHUI-IcwRgH5pQztHhUAZIIV3ZIaC0pwKxXfIDCSHnKHie-RDjL8AQCnJd8kuSsZRqhk5vnPVaAffd1lfZ3GM1q0HX_rGD5vMhMHXxg6Z77JVMJV33ZA7-9hnvjUr360OyPvaNNF93N598vP87MfpRX79fXl5enKdWy4Z5GVRVZIhVSgKFCWlBa1ZgZTXUFYouaQcKomccYCF5aKUC4cOKw5YGrUQbJ8cTbnr0P8ZXRx061PTpjGd68eoJZUqRRcJnE-gDX2MwdV6HVLXsNEI-v9eOu2lX_ZKhs_b5LFsXfWCTwMl_XCrm2hNUwfTWR-fMYEsteYJUxP21zdu88ZTfXN386pCPnl9HNy_Z68Jv_VCMin0_e1SfxUX598erq70kj0BpL-QfA</recordid><startdate>199201</startdate><enddate>199201</enddate><creator>Cho, Z. H.</creator><creator>Ro, Y. M.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Williams &amp; Wilkins</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199201</creationdate><title>Reduction of susceptibility artifact in gradient-echo imaging</title><author>Cho, Z. H. ; Ro, Y. M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4730-b8dd7312915815b2282f38124f0bd1747240d71434006c45b76e1e1d401ba9653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Biological and medical sciences</topic><topic>Humans</topic><topic>Image Enhancement - methods</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Medical sciences</topic><topic>Miscellaneous. Technology</topic><topic>Models, Theoretical</topic><topic>Nasal Cavity - anatomy &amp; histology</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Signal Processing, Computer-Assisted</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cho, Z. H.</creatorcontrib><creatorcontrib>Ro, Y. M.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cho, Z. H.</au><au>Ro, Y. M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reduction of susceptibility artifact in gradient-echo imaging</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn. Reson. Med</addtitle><date>1992-01</date><risdate>1992</risdate><volume>23</volume><issue>1</issue><spage>193</spage><epage>200</epage><pages>193-200</pages><issn>0740-3194</issn><eissn>1522-2594</eissn><coden>MRMEEN</coden><abstract>A new technique with which susceptibility artifact in gradient‐echo imaging can be reduced substantially by use of a tailored RF pulse is described. The proposed technique can ideally be applied to the case where high local magnetic field inhomogeneity is dominated by the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method is also proposed. The description of the tailored RF pulse and its proposed application are given and experimental results obtained using a human volunteer with a 2.0‐T KAIS NMR system are presented. © 1992 Academic Press, Inc.</abstract><cop>Baltimore</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>1734179</pmid><doi>10.1002/mrm.1910230120</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0740-3194
ispartof Magnetic resonance in medicine, 1992-01, Vol.23 (1), p.193-200
issn 0740-3194
1522-2594
language eng
recordid cdi_pascalfrancis_primary_5134344
source MEDLINE; Wiley Online Library Journals
subjects Biological and medical sciences
Humans
Image Enhancement - methods
Investigative techniques, diagnostic techniques (general aspects)
Magnetic Resonance Imaging - methods
Medical sciences
Miscellaneous. Technology
Models, Theoretical
Nasal Cavity - anatomy & histology
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Signal Processing, Computer-Assisted
title Reduction of susceptibility artifact in gradient-echo imaging
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T18%3A07%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reduction%20of%20susceptibility%20artifact%20in%20gradient-echo%20imaging&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Cho,%20Z.%20H.&rft.date=1992-01&rft.volume=23&rft.issue=1&rft.spage=193&rft.epage=200&rft.pages=193-200&rft.issn=0740-3194&rft.eissn=1522-2594&rft.coden=MRMEEN&rft_id=info:doi/10.1002/mrm.1910230120&rft_dat=%3Cproquest_cross%3E72795818%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72795818&rft_id=info:pmid/1734179&rfr_iscdi=true