Design and test of current limiting modules using YBCO-coated conductors

Within the cooperation between American Superconductor Corporation (AMSC) and Siemens Corporate Technology we have investigated the fault current limiting performance of YBCO-coated conductors (also called second-generation or 2G HTS wires) stabilized with stainless steel laminates. Design rules for...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Superconductor science & technology 2010-01, Vol.23 (1), p.014024-014024 (9)
Hauptverfasser: Schmidt, W, Gamble, B, Kraemer, H-P, Madura, D, Otto, A, Romanosky, W
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 014024 (9)
container_issue 1
container_start_page 014024
container_title Superconductor science & technology
container_volume 23
creator Schmidt, W
Gamble, B
Kraemer, H-P
Madura, D
Otto, A
Romanosky, W
description Within the cooperation between American Superconductor Corporation (AMSC) and Siemens Corporate Technology we have investigated the fault current limiting performance of YBCO-coated conductors (also called second-generation or 2G HTS wires) stabilized with stainless steel laminates. Design rules for the length and width of the wire depending on utility grid requirements have been established. Bifilar coils have been manufactured and tested with a typical limitation period of 50 ms under stepwise increasing voltage loads to determine the maximum temperature the wires can withstand without degradation. Coils have been assembled into limiter modules demonstrating uniform tripping of the individual coils and recovery within seconds. At present this cooperation is proceeding within a joint project funded by the US Department of Energy (DOE) that encompasses the design, construction and testing of a 115 kV FCL for power transmission within a time frame of 4-5 years, and additional partners. Besides AMSC and Siemens, Nexans contributes the high voltage terminations and Los Alamos National Lab investigates the ac losses. Installation and testing are planned for a Southern California Edison substation. The module planned for the transmission voltage application consists of 63 horizontally arranged coils connected in parallel and series to account for a rated current of 1.2 kArms and voltage of 31 kVrms plus margins. The rated voltage of the module is considerably lower than the line to ground voltage in the 115 kV grid owing to our shunted limiter concept. The shunt reactor connected in parallel to the module outside the cryostat allows for adjustment of the limited current and reduces voltage drop across the module in case of a fault. The fault current reduction ratio is 42% for our present design. A subscale module comprising six full-size coils has been assembled and tested recently to validate the coil performance and coil winding technique. The module had a critical current of 425 ADC and a nominal power of 2.52 MV A at 77 K. A complete series of tests with applied voltage up to 8.4 kVrms, prospective short circuit current up to 26.6 kArms and variation of phase angle at initiation of the fault has been performed. After more than 40 switching tests the critical current of the module remained unchanged, indicating that no degradation of the wire occurred.
doi_str_mv 10.1088/0953-2048/23/1/014024
format Article
fullrecord <record><control><sourceid>proquest_pasca</sourceid><recordid>TN_cdi_pascalfrancis_primary_22300777</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>855717627</sourcerecordid><originalsourceid>FETCH-LOGICAL-c421t-6ec063e0cc21167d6e86f937c2042001af80b29d94f61799ba73574b1b541a4f3</originalsourceid><addsrcrecordid>eNqNkE1LxDAQhoMouK7-BKEX8WLdTJIm6VHXjxUW9qIHTyGbJkulbWrSHvz3tnTZi4KehoHnnXl4EboEfAtYygXOM5oSzOSC0AUsMDBM2BGaAeWQcs7lMZodmFN0FuMHxgCSkhlaPdhY7ppEN0XS2dgl3iWmD8E2XVKVddmVzS6pfdFXNiZ9HLf3--UmNV53tkiMb4redD7Ec3TidBXtxX7O0dvT4-tyla43zy_Lu3VqGIEu5dZgTi02hgBwUXArucupMIMbGay0k3hL8iJnjoPI860WNBNsC9uMgWaOztH1dLcN_rMfjFVdRmOrSjfW91HJLBMgOBF_koJREEJmciCziTTBxxisU20oax2-FGA1VqzG-tRYnyJUgZoqHnJX-w86Gl25oBtTxkOYEIqxEKMJnrjSt_8-ffMz8iuq2sLRb0JDlXM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>743177858</pqid></control><display><type>article</type><title>Design and test of current limiting modules using YBCO-coated conductors</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Schmidt, W ; Gamble, B ; Kraemer, H-P ; Madura, D ; Otto, A ; Romanosky, W</creator><creatorcontrib>Schmidt, W ; Gamble, B ; Kraemer, H-P ; Madura, D ; Otto, A ; Romanosky, W</creatorcontrib><description>Within the cooperation between American Superconductor Corporation (AMSC) and Siemens Corporate Technology we have investigated the fault current limiting performance of YBCO-coated conductors (also called second-generation or 2G HTS wires) stabilized with stainless steel laminates. Design rules for the length and width of the wire depending on utility grid requirements have been established. Bifilar coils have been manufactured and tested with a typical limitation period of 50 ms under stepwise increasing voltage loads to determine the maximum temperature the wires can withstand without degradation. Coils have been assembled into limiter modules demonstrating uniform tripping of the individual coils and recovery within seconds. At present this cooperation is proceeding within a joint project funded by the US Department of Energy (DOE) that encompasses the design, construction and testing of a 115 kV FCL for power transmission within a time frame of 4-5 years, and additional partners. Besides AMSC and Siemens, Nexans contributes the high voltage terminations and Los Alamos National Lab investigates the ac losses. Installation and testing are planned for a Southern California Edison substation. The module planned for the transmission voltage application consists of 63 horizontally arranged coils connected in parallel and series to account for a rated current of 1.2 kArms and voltage of 31 kVrms plus margins. The rated voltage of the module is considerably lower than the line to ground voltage in the 115 kV grid owing to our shunted limiter concept. The shunt reactor connected in parallel to the module outside the cryostat allows for adjustment of the limited current and reduces voltage drop across the module in case of a fault. The fault current reduction ratio is 42% for our present design. A subscale module comprising six full-size coils has been assembled and tested recently to validate the coil performance and coil winding technique. The module had a critical current of 425 ADC and a nominal power of 2.52 MV A at 77 K. A complete series of tests with applied voltage up to 8.4 kVrms, prospective short circuit current up to 26.6 kArms and variation of phase angle at initiation of the fault has been performed. After more than 40 switching tests the critical current of the module remained unchanged, indicating that no degradation of the wire occurred.</description><identifier>ISSN: 0953-2048</identifier><identifier>EISSN: 1361-6668</identifier><identifier>DOI: 10.1088/0953-2048/23/1/014024</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Applied sciences ; COATINGS ; Coils ; Connection and protection apparatus ; Constraining ; COPPER OXIDE ; Degradation ; Electric potential ; ELECTRICAL CONDUCTORS ; Electrical engineering. Electrical power engineering ; Exact sciences and technology ; Faults ; LAMINATES ; Modules ; SUPERCONDUCTORS ; VOLTAGE ; WIRE ; YTTRIUM OXIDE</subject><ispartof>Superconductor science &amp; technology, 2010-01, Vol.23 (1), p.014024-014024 (9)</ispartof><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c421t-6ec063e0cc21167d6e86f937c2042001af80b29d94f61799ba73574b1b541a4f3</citedby><cites>FETCH-LOGICAL-c421t-6ec063e0cc21167d6e86f937c2042001af80b29d94f61799ba73574b1b541a4f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0953-2048/23/1/014024/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,778,782,27911,27912,53817,53897</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=22300777$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Schmidt, W</creatorcontrib><creatorcontrib>Gamble, B</creatorcontrib><creatorcontrib>Kraemer, H-P</creatorcontrib><creatorcontrib>Madura, D</creatorcontrib><creatorcontrib>Otto, A</creatorcontrib><creatorcontrib>Romanosky, W</creatorcontrib><title>Design and test of current limiting modules using YBCO-coated conductors</title><title>Superconductor science &amp; technology</title><description>Within the cooperation between American Superconductor Corporation (AMSC) and Siemens Corporate Technology we have investigated the fault current limiting performance of YBCO-coated conductors (also called second-generation or 2G HTS wires) stabilized with stainless steel laminates. Design rules for the length and width of the wire depending on utility grid requirements have been established. Bifilar coils have been manufactured and tested with a typical limitation period of 50 ms under stepwise increasing voltage loads to determine the maximum temperature the wires can withstand without degradation. Coils have been assembled into limiter modules demonstrating uniform tripping of the individual coils and recovery within seconds. At present this cooperation is proceeding within a joint project funded by the US Department of Energy (DOE) that encompasses the design, construction and testing of a 115 kV FCL for power transmission within a time frame of 4-5 years, and additional partners. Besides AMSC and Siemens, Nexans contributes the high voltage terminations and Los Alamos National Lab investigates the ac losses. Installation and testing are planned for a Southern California Edison substation. The module planned for the transmission voltage application consists of 63 horizontally arranged coils connected in parallel and series to account for a rated current of 1.2 kArms and voltage of 31 kVrms plus margins. The rated voltage of the module is considerably lower than the line to ground voltage in the 115 kV grid owing to our shunted limiter concept. The shunt reactor connected in parallel to the module outside the cryostat allows for adjustment of the limited current and reduces voltage drop across the module in case of a fault. The fault current reduction ratio is 42% for our present design. A subscale module comprising six full-size coils has been assembled and tested recently to validate the coil performance and coil winding technique. The module had a critical current of 425 ADC and a nominal power of 2.52 MV A at 77 K. A complete series of tests with applied voltage up to 8.4 kVrms, prospective short circuit current up to 26.6 kArms and variation of phase angle at initiation of the fault has been performed. After more than 40 switching tests the critical current of the module remained unchanged, indicating that no degradation of the wire occurred.</description><subject>Applied sciences</subject><subject>COATINGS</subject><subject>Coils</subject><subject>Connection and protection apparatus</subject><subject>Constraining</subject><subject>COPPER OXIDE</subject><subject>Degradation</subject><subject>Electric potential</subject><subject>ELECTRICAL CONDUCTORS</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Exact sciences and technology</subject><subject>Faults</subject><subject>LAMINATES</subject><subject>Modules</subject><subject>SUPERCONDUCTORS</subject><subject>VOLTAGE</subject><subject>WIRE</subject><subject>YTTRIUM OXIDE</subject><issn>0953-2048</issn><issn>1361-6668</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqNkE1LxDAQhoMouK7-BKEX8WLdTJIm6VHXjxUW9qIHTyGbJkulbWrSHvz3tnTZi4KehoHnnXl4EboEfAtYygXOM5oSzOSC0AUsMDBM2BGaAeWQcs7lMZodmFN0FuMHxgCSkhlaPdhY7ppEN0XS2dgl3iWmD8E2XVKVddmVzS6pfdFXNiZ9HLf3--UmNV53tkiMb4redD7Ec3TidBXtxX7O0dvT4-tyla43zy_Lu3VqGIEu5dZgTi02hgBwUXArucupMIMbGay0k3hL8iJnjoPI860WNBNsC9uMgWaOztH1dLcN_rMfjFVdRmOrSjfW91HJLBMgOBF_koJREEJmciCziTTBxxisU20oax2-FGA1VqzG-tRYnyJUgZoqHnJX-w86Gl25oBtTxkOYEIqxEKMJnrjSt_8-ffMz8iuq2sLRb0JDlXM</recordid><startdate>20100101</startdate><enddate>20100101</enddate><creator>Schmidt, W</creator><creator>Gamble, B</creator><creator>Kraemer, H-P</creator><creator>Madura, D</creator><creator>Otto, A</creator><creator>Romanosky, W</creator><general>IOP Publishing</general><general>Institute of Physics</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8G</scope><scope>JG9</scope><scope>L7M</scope><scope>7QQ</scope></search><sort><creationdate>20100101</creationdate><title>Design and test of current limiting modules using YBCO-coated conductors</title><author>Schmidt, W ; Gamble, B ; Kraemer, H-P ; Madura, D ; Otto, A ; Romanosky, W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c421t-6ec063e0cc21167d6e86f937c2042001af80b29d94f61799ba73574b1b541a4f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Applied sciences</topic><topic>COATINGS</topic><topic>Coils</topic><topic>Connection and protection apparatus</topic><topic>Constraining</topic><topic>COPPER OXIDE</topic><topic>Degradation</topic><topic>Electric potential</topic><topic>ELECTRICAL CONDUCTORS</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Exact sciences and technology</topic><topic>Faults</topic><topic>LAMINATES</topic><topic>Modules</topic><topic>SUPERCONDUCTORS</topic><topic>VOLTAGE</topic><topic>WIRE</topic><topic>YTTRIUM OXIDE</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schmidt, W</creatorcontrib><creatorcontrib>Gamble, B</creatorcontrib><creatorcontrib>Kraemer, H-P</creatorcontrib><creatorcontrib>Madura, D</creatorcontrib><creatorcontrib>Otto, A</creatorcontrib><creatorcontrib>Romanosky, W</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Ceramic Abstracts</collection><jtitle>Superconductor science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schmidt, W</au><au>Gamble, B</au><au>Kraemer, H-P</au><au>Madura, D</au><au>Otto, A</au><au>Romanosky, W</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and test of current limiting modules using YBCO-coated conductors</atitle><jtitle>Superconductor science &amp; technology</jtitle><date>2010-01-01</date><risdate>2010</risdate><volume>23</volume><issue>1</issue><spage>014024</spage><epage>014024 (9)</epage><pages>014024-014024 (9)</pages><issn>0953-2048</issn><eissn>1361-6668</eissn><abstract>Within the cooperation between American Superconductor Corporation (AMSC) and Siemens Corporate Technology we have investigated the fault current limiting performance of YBCO-coated conductors (also called second-generation or 2G HTS wires) stabilized with stainless steel laminates. Design rules for the length and width of the wire depending on utility grid requirements have been established. Bifilar coils have been manufactured and tested with a typical limitation period of 50 ms under stepwise increasing voltage loads to determine the maximum temperature the wires can withstand without degradation. Coils have been assembled into limiter modules demonstrating uniform tripping of the individual coils and recovery within seconds. At present this cooperation is proceeding within a joint project funded by the US Department of Energy (DOE) that encompasses the design, construction and testing of a 115 kV FCL for power transmission within a time frame of 4-5 years, and additional partners. Besides AMSC and Siemens, Nexans contributes the high voltage terminations and Los Alamos National Lab investigates the ac losses. Installation and testing are planned for a Southern California Edison substation. The module planned for the transmission voltage application consists of 63 horizontally arranged coils connected in parallel and series to account for a rated current of 1.2 kArms and voltage of 31 kVrms plus margins. The rated voltage of the module is considerably lower than the line to ground voltage in the 115 kV grid owing to our shunted limiter concept. The shunt reactor connected in parallel to the module outside the cryostat allows for adjustment of the limited current and reduces voltage drop across the module in case of a fault. The fault current reduction ratio is 42% for our present design. A subscale module comprising six full-size coils has been assembled and tested recently to validate the coil performance and coil winding technique. The module had a critical current of 425 ADC and a nominal power of 2.52 MV A at 77 K. A complete series of tests with applied voltage up to 8.4 kVrms, prospective short circuit current up to 26.6 kArms and variation of phase angle at initiation of the fault has been performed. After more than 40 switching tests the critical current of the module remained unchanged, indicating that no degradation of the wire occurred.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/0953-2048/23/1/014024</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0953-2048
ispartof Superconductor science & technology, 2010-01, Vol.23 (1), p.014024-014024 (9)
issn 0953-2048
1361-6668
language eng
recordid cdi_pascalfrancis_primary_22300777
source IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Applied sciences
COATINGS
Coils
Connection and protection apparatus
Constraining
COPPER OXIDE
Degradation
Electric potential
ELECTRICAL CONDUCTORS
Electrical engineering. Electrical power engineering
Exact sciences and technology
Faults
LAMINATES
Modules
SUPERCONDUCTORS
VOLTAGE
WIRE
YTTRIUM OXIDE
title Design and test of current limiting modules using YBCO-coated conductors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T19%3A43%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pasca&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20test%20of%20current%20limiting%20modules%20using%20YBCO-coated%20conductors&rft.jtitle=Superconductor%20science%20&%20technology&rft.au=Schmidt,%20W&rft.date=2010-01-01&rft.volume=23&rft.issue=1&rft.spage=014024&rft.epage=014024%20(9)&rft.pages=014024-014024%20(9)&rft.issn=0953-2048&rft.eissn=1361-6668&rft_id=info:doi/10.1088/0953-2048/23/1/014024&rft_dat=%3Cproquest_pasca%3E855717627%3C/proquest_pasca%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=743177858&rft_id=info:pmid/&rfr_iscdi=true