Transient Measurements of Radiative Properties, Soot Volume Fraction and Soot Temperature in a Large Pool Fire

Multi-wavelength absorption/emission measurements of extinction coefficient, temperature, and soot volume fraction in a large (6 m by 6 m) JP8 pool fire using an in situ water-cooled fiberoptic probe are reported. These measurements provide the first in situ information on radiative properties, temp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Combustion science and technology 1998-10, Vol.139 (1), p.113-136
Hauptverfasser: GRITZO, L. A., SIVATHANU, Y. R., GILL, W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 136
container_issue 1
container_start_page 113
container_title Combustion science and technology
container_volume 139
creator GRITZO, L. A.
SIVATHANU, Y. R.
GILL, W.
description Multi-wavelength absorption/emission measurements of extinction coefficient, temperature, and soot volume fraction in a large (6 m by 6 m) JP8 pool fire using an in situ water-cooled fiberoptic probe are reported. These measurements provide the first in situ information on radiative properties, temperature, soot, and the associated time scales in large pool tires. Soot extinction coefficients on the order of 5 to 30m -1 were measured in the visible regime, indicating paths lengths for radiative transport in the infrared of approximately 0.1 to 0.3 m. Temperature measurements follow an approximately normal distribution with a mean of 1400 K. and a standard deviation of approximately 67 K. Integral length scales of approximately 0.25 m were deduced from the temperature data. This length scale corresponds to the size of the smaller combusting eddies visually observed in large fires. Soot concentration integral length scales of 1.4 m were determined from the absorption measurements. Soot volume fractions ranging from 0 to 6.0 ppm were measured. In comparison to laboratory-scale flames, excellent agreement was observed between the volume fractions determined by extinction and emission measurements, indicating a uniform temperature distribution (and hence uniform flame coverage) within the 2.0 cm long by 1.0 cm diameter cylindrical sampling volume. Soot volume fractions determined by emission show a strong peak in the PDF just above 1.0 ppm. The same peak is observed on the soot volume fraction determined by absorption, but an additional maxima in the PDF is observed near 3.0 ppm, indicating the occasional presence of thick, cold soot. The primary uncertainty in the results is due to uncertainty in the soot indices of refraction. Fortunately, the uniform flame volume observed in the results show that the environment is promising for the study of these refractive indices.
doi_str_mv 10.1080/00102209808952083
format Article
fullrecord <record><control><sourceid>pascalfrancis_infor</sourceid><recordid>TN_cdi_pascalfrancis_primary_1733286</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1733286</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-d6e049cf3b232e05853b0dd507410d787ed107433083fecea988f5ed8535d7bd3</originalsourceid><addsrcrecordid>eNqFkE9LAzEQxYMoWKsfwFsOHl3Nn6abBS9SrAoVRat4W9JkIpHdTUlStd_elFU8iHiamcz7PSYPoUNKTiiR5JQQShgjlSSyEoxIvoUGVIx5IRh93kaDzb7IAraL9mJ8zSPnjA5QNw-qiw66hG9AxVWANvcRe4vvlXEquTfAd8EvISQH8Rg_eJ_wk29WLeBpUDo532HVmX4xhzYrVco-2OV3PFPhJRt43-CpC7CPdqxqIhx81SF6nF7MJ1fF7PbyenI-KzQveSrMGMio0pYvGGdAhBR8QYwRpBxRYkpZgqG55zx_1IIGVUlpBZisE6ZcGD5EtPfVwccYwNbL4FoV1jUl9Saw-ldgmTnqmaWKWjU2B6Nd_AHLnJgcZ1nZy1xnfWjVuw-NqZNaNz58M7_M6_SRMnn2L8n_vu8TWRuQRA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Transient Measurements of Radiative Properties, Soot Volume Fraction and Soot Temperature in a Large Pool Fire</title><source>Taylor &amp; Francis</source><creator>GRITZO, L. A. ; SIVATHANU, Y. R. ; GILL, W.</creator><creatorcontrib>GRITZO, L. A. ; SIVATHANU, Y. R. ; GILL, W.</creatorcontrib><description>Multi-wavelength absorption/emission measurements of extinction coefficient, temperature, and soot volume fraction in a large (6 m by 6 m) JP8 pool fire using an in situ water-cooled fiberoptic probe are reported. These measurements provide the first in situ information on radiative properties, temperature, soot, and the associated time scales in large pool tires. Soot extinction coefficients on the order of 5 to 30m -1 were measured in the visible regime, indicating paths lengths for radiative transport in the infrared of approximately 0.1 to 0.3 m. Temperature measurements follow an approximately normal distribution with a mean of 1400 K. and a standard deviation of approximately 67 K. Integral length scales of approximately 0.25 m were deduced from the temperature data. This length scale corresponds to the size of the smaller combusting eddies visually observed in large fires. Soot concentration integral length scales of 1.4 m were determined from the absorption measurements. Soot volume fractions ranging from 0 to 6.0 ppm were measured. In comparison to laboratory-scale flames, excellent agreement was observed between the volume fractions determined by extinction and emission measurements, indicating a uniform temperature distribution (and hence uniform flame coverage) within the 2.0 cm long by 1.0 cm diameter cylindrical sampling volume. Soot volume fractions determined by emission show a strong peak in the PDF just above 1.0 ppm. The same peak is observed on the soot volume fraction determined by absorption, but an additional maxima in the PDF is observed near 3.0 ppm, indicating the occasional presence of thick, cold soot. The primary uncertainty in the results is due to uncertainty in the soot indices of refraction. Fortunately, the uniform flame volume observed in the results show that the environment is promising for the study of these refractive indices.</description><identifier>ISSN: 0010-2202</identifier><identifier>EISSN: 1563-521X</identifier><identifier>DOI: 10.1080/00102209808952083</identifier><identifier>CODEN: CBSTB9</identifier><language>eng</language><publisher>London: Taylor &amp; Francis Group</publisher><subject>Applied sciences ; Combustion. Flame ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Fire ; Miscellaneous ; soot ; temperature ; Theoretical studies. Data and constants. Metering</subject><ispartof>Combustion science and technology, 1998-10, Vol.139 (1), p.113-136</ispartof><rights>Copyright Taylor &amp; Francis Group, LLC 1998</rights><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-d6e049cf3b232e05853b0dd507410d787ed107433083fecea988f5ed8535d7bd3</citedby><cites>FETCH-LOGICAL-c373t-d6e049cf3b232e05853b0dd507410d787ed107433083fecea988f5ed8535d7bd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.1080/00102209808952083$$EPDF$$P50$$Ginformaworld$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.1080/00102209808952083$$EHTML$$P50$$Ginformaworld$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,59620,60409</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1733286$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>GRITZO, L. A.</creatorcontrib><creatorcontrib>SIVATHANU, Y. R.</creatorcontrib><creatorcontrib>GILL, W.</creatorcontrib><title>Transient Measurements of Radiative Properties, Soot Volume Fraction and Soot Temperature in a Large Pool Fire</title><title>Combustion science and technology</title><description>Multi-wavelength absorption/emission measurements of extinction coefficient, temperature, and soot volume fraction in a large (6 m by 6 m) JP8 pool fire using an in situ water-cooled fiberoptic probe are reported. These measurements provide the first in situ information on radiative properties, temperature, soot, and the associated time scales in large pool tires. Soot extinction coefficients on the order of 5 to 30m -1 were measured in the visible regime, indicating paths lengths for radiative transport in the infrared of approximately 0.1 to 0.3 m. Temperature measurements follow an approximately normal distribution with a mean of 1400 K. and a standard deviation of approximately 67 K. Integral length scales of approximately 0.25 m were deduced from the temperature data. This length scale corresponds to the size of the smaller combusting eddies visually observed in large fires. Soot concentration integral length scales of 1.4 m were determined from the absorption measurements. Soot volume fractions ranging from 0 to 6.0 ppm were measured. In comparison to laboratory-scale flames, excellent agreement was observed between the volume fractions determined by extinction and emission measurements, indicating a uniform temperature distribution (and hence uniform flame coverage) within the 2.0 cm long by 1.0 cm diameter cylindrical sampling volume. Soot volume fractions determined by emission show a strong peak in the PDF just above 1.0 ppm. The same peak is observed on the soot volume fraction determined by absorption, but an additional maxima in the PDF is observed near 3.0 ppm, indicating the occasional presence of thick, cold soot. The primary uncertainty in the results is due to uncertainty in the soot indices of refraction. Fortunately, the uniform flame volume observed in the results show that the environment is promising for the study of these refractive indices.</description><subject>Applied sciences</subject><subject>Combustion. Flame</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Fire</subject><subject>Miscellaneous</subject><subject>soot</subject><subject>temperature</subject><subject>Theoretical studies. Data and constants. Metering</subject><issn>0010-2202</issn><issn>1563-521X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkE9LAzEQxYMoWKsfwFsOHl3Nn6abBS9SrAoVRat4W9JkIpHdTUlStd_elFU8iHiamcz7PSYPoUNKTiiR5JQQShgjlSSyEoxIvoUGVIx5IRh93kaDzb7IAraL9mJ8zSPnjA5QNw-qiw66hG9AxVWANvcRe4vvlXEquTfAd8EvISQH8Rg_eJ_wk29WLeBpUDo532HVmX4xhzYrVco-2OV3PFPhJRt43-CpC7CPdqxqIhx81SF6nF7MJ1fF7PbyenI-KzQveSrMGMio0pYvGGdAhBR8QYwRpBxRYkpZgqG55zx_1IIGVUlpBZisE6ZcGD5EtPfVwccYwNbL4FoV1jUl9Saw-ldgmTnqmaWKWjU2B6Nd_AHLnJgcZ1nZy1xnfWjVuw-NqZNaNz58M7_M6_SRMnn2L8n_vu8TWRuQRA</recordid><startdate>19981001</startdate><enddate>19981001</enddate><creator>GRITZO, L. A.</creator><creator>SIVATHANU, Y. R.</creator><creator>GILL, W.</creator><general>Taylor &amp; Francis Group</general><general>Taylor &amp; Francis</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19981001</creationdate><title>Transient Measurements of Radiative Properties, Soot Volume Fraction and Soot Temperature in a Large Pool Fire</title><author>GRITZO, L. A. ; SIVATHANU, Y. R. ; GILL, W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-d6e049cf3b232e05853b0dd507410d787ed107433083fecea988f5ed8535d7bd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Applied sciences</topic><topic>Combustion. Flame</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Fire</topic><topic>Miscellaneous</topic><topic>soot</topic><topic>temperature</topic><topic>Theoretical studies. Data and constants. Metering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>GRITZO, L. A.</creatorcontrib><creatorcontrib>SIVATHANU, Y. R.</creatorcontrib><creatorcontrib>GILL, W.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Combustion science and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>GRITZO, L. A.</au><au>SIVATHANU, Y. R.</au><au>GILL, W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transient Measurements of Radiative Properties, Soot Volume Fraction and Soot Temperature in a Large Pool Fire</atitle><jtitle>Combustion science and technology</jtitle><date>1998-10-01</date><risdate>1998</risdate><volume>139</volume><issue>1</issue><spage>113</spage><epage>136</epage><pages>113-136</pages><issn>0010-2202</issn><eissn>1563-521X</eissn><coden>CBSTB9</coden><abstract>Multi-wavelength absorption/emission measurements of extinction coefficient, temperature, and soot volume fraction in a large (6 m by 6 m) JP8 pool fire using an in situ water-cooled fiberoptic probe are reported. These measurements provide the first in situ information on radiative properties, temperature, soot, and the associated time scales in large pool tires. Soot extinction coefficients on the order of 5 to 30m -1 were measured in the visible regime, indicating paths lengths for radiative transport in the infrared of approximately 0.1 to 0.3 m. Temperature measurements follow an approximately normal distribution with a mean of 1400 K. and a standard deviation of approximately 67 K. Integral length scales of approximately 0.25 m were deduced from the temperature data. This length scale corresponds to the size of the smaller combusting eddies visually observed in large fires. Soot concentration integral length scales of 1.4 m were determined from the absorption measurements. Soot volume fractions ranging from 0 to 6.0 ppm were measured. In comparison to laboratory-scale flames, excellent agreement was observed between the volume fractions determined by extinction and emission measurements, indicating a uniform temperature distribution (and hence uniform flame coverage) within the 2.0 cm long by 1.0 cm diameter cylindrical sampling volume. Soot volume fractions determined by emission show a strong peak in the PDF just above 1.0 ppm. The same peak is observed on the soot volume fraction determined by absorption, but an additional maxima in the PDF is observed near 3.0 ppm, indicating the occasional presence of thick, cold soot. The primary uncertainty in the results is due to uncertainty in the soot indices of refraction. Fortunately, the uniform flame volume observed in the results show that the environment is promising for the study of these refractive indices.</abstract><cop>London</cop><pub>Taylor &amp; Francis Group</pub><doi>10.1080/00102209808952083</doi><tpages>24</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0010-2202
ispartof Combustion science and technology, 1998-10, Vol.139 (1), p.113-136
issn 0010-2202
1563-521X
language eng
recordid cdi_pascalfrancis_primary_1733286
source Taylor & Francis
subjects Applied sciences
Combustion. Flame
Energy
Energy. Thermal use of fuels
Exact sciences and technology
Fire
Miscellaneous
soot
temperature
Theoretical studies. Data and constants. Metering
title Transient Measurements of Radiative Properties, Soot Volume Fraction and Soot Temperature in a Large Pool Fire
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T09%3A50%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pascalfrancis_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transient%20Measurements%20of%20Radiative%20Properties,%20Soot%20Volume%20Fraction%20and%20Soot%20Temperature%20in%20a%20Large%20Pool%20Fire&rft.jtitle=Combustion%20science%20and%20technology&rft.au=GRITZO,%20L.%20A.&rft.date=1998-10-01&rft.volume=139&rft.issue=1&rft.spage=113&rft.epage=136&rft.pages=113-136&rft.issn=0010-2202&rft.eissn=1563-521X&rft.coden=CBSTB9&rft_id=info:doi/10.1080/00102209808952083&rft_dat=%3Cpascalfrancis_infor%3E1733286%3C/pascalfrancis_infor%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true