Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficie...
Gespeichert in:
Veröffentlicht in: | Physical review letters 2009-01, Vol.102 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | Physical review letters |
container_volume | 102 |
creator | Lachniet, J. Bouchigny, S. Fradi, A. Guidal, M. Hadjidakis, C. S. Jo, H. Maccormick, M. Moreno, B. Niccolai, S. de Masi, R. Garçon, M. X. Girod, F. Konczykowski, P. M. Laget, J. Morrow, S.A. Sabatié, F. |
description | The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data. |
doi_str_mv | 10.1103/PhysRevLett.102.192001 |
format | Article |
fullrecord | <record><control><sourceid>hal_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_956239</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_HAL_in2p3_00868287v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-h132t-6bb3f93faa7ea80137edd4d0fea964e37e791f04af4dac746d67bac0b16d18b73</originalsourceid><addsrcrecordid>eNotzFFLwzAYheEgCs7pX5B4LZ1fkpo0l2O4Teh0DPW2pOnXNbIlo8km-_cO59XhhYdDyD2DEWMgnpbdMa7wUGJKIwZ8xDQHYBdkwEDpTDGWX5IBgGCZBlDX5CbGbzgJLosBWS17tC4iXaCJ-x636BMNLU0d0jfcpz54ujBrj8lZOg39lk6NTaGns4Wnzv-5Kf5kM_zidIVrF_wtuWrNJuLd_w7J5_TlYzLPyvfZ62RcZh0TPGWyrkWrRWuMQlMAEwqbJm-gRaNljqdUmrWQmzZvjFW5bKSqjYWayYYVtRJD8nD-DTG5KlqX0HY2eI82VfpZcqFP5vFsOrOpdr3bmv5YBeOq-bisnOc7UQEUsuCFOjDxC-gzYkQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region</title><source>American Physical Society Journals</source><creator>Lachniet, J. ; Bouchigny, S. ; Fradi, A. ; Guidal, M. ; Hadjidakis, C. ; S. Jo, H. ; Maccormick, M. ; Moreno, B. ; Niccolai, S. ; de Masi, R. ; Garçon, M. ; X. Girod, F. ; Konczykowski, P. ; M. Laget, J. ; Morrow, S.A. ; Sabatié, F.</creator><creatorcontrib>Lachniet, J. ; Bouchigny, S. ; Fradi, A. ; Guidal, M. ; Hadjidakis, C. ; S. Jo, H. ; Maccormick, M. ; Moreno, B. ; Niccolai, S. ; de Masi, R. ; Garçon, M. ; X. Girod, F. ; Konczykowski, P. ; M. Laget, J. ; Morrow, S.A. ; Sabatié, F. ; Thomas Jefferson Lab National Accelerator Facility</creatorcontrib><description>The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.</description><identifier>ISSN: 0031-9007</identifier><identifier>EISSN: 1079-7114</identifier><identifier>DOI: 10.1103/PhysRevLett.102.192001</identifier><language>eng</language><publisher>United States: American Physical Society</publisher><subject>ACCURACY ; CALIBRATION ; CALORIMETERS ; DEUTERIUM ; DIPOLES ; EFFICIENCY ; ELECTRON BEAMS ; ELECTRONS ; FORM FACTORS ; NEUTRON DETECTION ; NEUTRONS ; Nuclear Experiment ; PHOSPHORS ; Physics ; PHYSICS OF ELEMENTARY PARTICLES AND FIELDS ; SCATTERING ; SPECTROMETERS</subject><ispartof>Physical review letters, 2009-01, Vol.102</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://in2p3.hal.science/in2p3-00868287$$DView record in HAL$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/servlets/purl/956239$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Lachniet, J.</creatorcontrib><creatorcontrib>Bouchigny, S.</creatorcontrib><creatorcontrib>Fradi, A.</creatorcontrib><creatorcontrib>Guidal, M.</creatorcontrib><creatorcontrib>Hadjidakis, C.</creatorcontrib><creatorcontrib>S. Jo, H.</creatorcontrib><creatorcontrib>Maccormick, M.</creatorcontrib><creatorcontrib>Moreno, B.</creatorcontrib><creatorcontrib>Niccolai, S.</creatorcontrib><creatorcontrib>de Masi, R.</creatorcontrib><creatorcontrib>Garçon, M.</creatorcontrib><creatorcontrib>X. Girod, F.</creatorcontrib><creatorcontrib>Konczykowski, P.</creatorcontrib><creatorcontrib>M. Laget, J.</creatorcontrib><creatorcontrib>Morrow, S.A.</creatorcontrib><creatorcontrib>Sabatié, F.</creatorcontrib><creatorcontrib>Thomas Jefferson Lab National Accelerator Facility</creatorcontrib><title>Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region</title><title>Physical review letters</title><description>The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.</description><subject>ACCURACY</subject><subject>CALIBRATION</subject><subject>CALORIMETERS</subject><subject>DEUTERIUM</subject><subject>DIPOLES</subject><subject>EFFICIENCY</subject><subject>ELECTRON BEAMS</subject><subject>ELECTRONS</subject><subject>FORM FACTORS</subject><subject>NEUTRON DETECTION</subject><subject>NEUTRONS</subject><subject>Nuclear Experiment</subject><subject>PHOSPHORS</subject><subject>Physics</subject><subject>PHYSICS OF ELEMENTARY PARTICLES AND FIELDS</subject><subject>SCATTERING</subject><subject>SPECTROMETERS</subject><issn>0031-9007</issn><issn>1079-7114</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNotzFFLwzAYheEgCs7pX5B4LZ1fkpo0l2O4Teh0DPW2pOnXNbIlo8km-_cO59XhhYdDyD2DEWMgnpbdMa7wUGJKIwZ8xDQHYBdkwEDpTDGWX5IBgGCZBlDX5CbGbzgJLosBWS17tC4iXaCJ-x636BMNLU0d0jfcpz54ujBrj8lZOg39lk6NTaGns4Wnzv-5Kf5kM_zidIVrF_wtuWrNJuLd_w7J5_TlYzLPyvfZ62RcZh0TPGWyrkWrRWuMQlMAEwqbJm-gRaNljqdUmrWQmzZvjFW5bKSqjYWayYYVtRJD8nD-DTG5KlqX0HY2eI82VfpZcqFP5vFsOrOpdr3bmv5YBeOq-bisnOc7UQEUsuCFOjDxC-gzYkQ</recordid><startdate>20090101</startdate><enddate>20090101</enddate><creator>Lachniet, J.</creator><creator>Bouchigny, S.</creator><creator>Fradi, A.</creator><creator>Guidal, M.</creator><creator>Hadjidakis, C.</creator><creator>S. Jo, H.</creator><creator>Maccormick, M.</creator><creator>Moreno, B.</creator><creator>Niccolai, S.</creator><creator>de Masi, R.</creator><creator>Garçon, M.</creator><creator>X. Girod, F.</creator><creator>Konczykowski, P.</creator><creator>M. Laget, J.</creator><creator>Morrow, S.A.</creator><creator>Sabatié, F.</creator><general>American Physical Society</general><scope>1XC</scope><scope>OIOZB</scope><scope>OTOTI</scope></search><sort><creationdate>20090101</creationdate><title>Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region</title><author>Lachniet, J. ; Bouchigny, S. ; Fradi, A. ; Guidal, M. ; Hadjidakis, C. ; S. Jo, H. ; Maccormick, M. ; Moreno, B. ; Niccolai, S. ; de Masi, R. ; Garçon, M. ; X. Girod, F. ; Konczykowski, P. ; M. Laget, J. ; Morrow, S.A. ; Sabatié, F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-h132t-6bb3f93faa7ea80137edd4d0fea964e37e791f04af4dac746d67bac0b16d18b73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>ACCURACY</topic><topic>CALIBRATION</topic><topic>CALORIMETERS</topic><topic>DEUTERIUM</topic><topic>DIPOLES</topic><topic>EFFICIENCY</topic><topic>ELECTRON BEAMS</topic><topic>ELECTRONS</topic><topic>FORM FACTORS</topic><topic>NEUTRON DETECTION</topic><topic>NEUTRONS</topic><topic>Nuclear Experiment</topic><topic>PHOSPHORS</topic><topic>Physics</topic><topic>PHYSICS OF ELEMENTARY PARTICLES AND FIELDS</topic><topic>SCATTERING</topic><topic>SPECTROMETERS</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lachniet, J.</creatorcontrib><creatorcontrib>Bouchigny, S.</creatorcontrib><creatorcontrib>Fradi, A.</creatorcontrib><creatorcontrib>Guidal, M.</creatorcontrib><creatorcontrib>Hadjidakis, C.</creatorcontrib><creatorcontrib>S. Jo, H.</creatorcontrib><creatorcontrib>Maccormick, M.</creatorcontrib><creatorcontrib>Moreno, B.</creatorcontrib><creatorcontrib>Niccolai, S.</creatorcontrib><creatorcontrib>de Masi, R.</creatorcontrib><creatorcontrib>Garçon, M.</creatorcontrib><creatorcontrib>X. Girod, F.</creatorcontrib><creatorcontrib>Konczykowski, P.</creatorcontrib><creatorcontrib>M. Laget, J.</creatorcontrib><creatorcontrib>Morrow, S.A.</creatorcontrib><creatorcontrib>Sabatié, F.</creatorcontrib><creatorcontrib>Thomas Jefferson Lab National Accelerator Facility</creatorcontrib><collection>Hyper Article en Ligne (HAL)</collection><collection>OSTI.GOV - Hybrid</collection><collection>OSTI.GOV</collection><jtitle>Physical review letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lachniet, J.</au><au>Bouchigny, S.</au><au>Fradi, A.</au><au>Guidal, M.</au><au>Hadjidakis, C.</au><au>S. Jo, H.</au><au>Maccormick, M.</au><au>Moreno, B.</au><au>Niccolai, S.</au><au>de Masi, R.</au><au>Garçon, M.</au><au>X. Girod, F.</au><au>Konczykowski, P.</au><au>M. Laget, J.</au><au>Morrow, S.A.</au><au>Sabatié, F.</au><aucorp>Thomas Jefferson Lab National Accelerator Facility</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region</atitle><jtitle>Physical review letters</jtitle><date>2009-01-01</date><risdate>2009</risdate><volume>102</volume><issn>0031-9007</issn><eissn>1079-7114</eissn><abstract>The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.</abstract><cop>United States</cop><pub>American Physical Society</pub><doi>10.1103/PhysRevLett.102.192001</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0031-9007 |
ispartof | Physical review letters, 2009-01, Vol.102 |
issn | 0031-9007 1079-7114 |
language | eng |
recordid | cdi_osti_scitechconnect_956239 |
source | American Physical Society Journals |
subjects | ACCURACY CALIBRATION CALORIMETERS DEUTERIUM DIPOLES EFFICIENCY ELECTRON BEAMS ELECTRONS FORM FACTORS NEUTRON DETECTION NEUTRONS Nuclear Experiment PHOSPHORS Physics PHYSICS OF ELEMENTARY PARTICLES AND FIELDS SCATTERING SPECTROMETERS |
title | Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T20%3A07%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Precise%20Measurement%20of%20the%20Neutron%20Magnetic%20Form%20Factor%20GMn%20in%20the%20Few-GeV2%20Region&rft.jtitle=Physical%20review%20letters&rft.au=Lachniet,%20J.&rft.aucorp=Thomas%20Jefferson%20Lab%20National%20Accelerator%20Facility&rft.date=2009-01-01&rft.volume=102&rft.issn=0031-9007&rft.eissn=1079-7114&rft_id=info:doi/10.1103/PhysRevLett.102.192001&rft_dat=%3Chal_osti_%3Eoai_HAL_in2p3_00868287v1%3C/hal_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |