On cooling silicon surface-barrier particle detectors

The energy resolution of a surface-barrier silicon detector, thermoelectrically cooled, has been measured from 20°C to −30°C. Different thermic screens have been used in order to evidence the effect of thermic gradients inside the detector.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods 1973-10, Vol.112 (3), p.591-595
Hauptverfasser: Calligaris, F., Ciuti, P., Gabrielli, I., Giacomich, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 595
container_issue 3
container_start_page 591
container_title Nuclear instruments & methods
container_volume 112
creator Calligaris, F.
Ciuti, P.
Gabrielli, I.
Giacomich, R.
description The energy resolution of a surface-barrier silicon detector, thermoelectrically cooled, has been measured from 20°C to −30°C. Different thermic screens have been used in order to evidence the effect of thermic gradients inside the detector.
doi_str_mv 10.1016/0029-554X(73)90184-5
format Article
fullrecord <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_4388597</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0029554X73901845</els_id><sourcerecordid>0029554X73901845</sourcerecordid><originalsourceid>FETCH-LOGICAL-c333t-62ebef826e03cdc311dae618b31b438f6ba15160250ee2b6819a5e5ca29fbe013</originalsourceid><addsrcrecordid>eNp9kE9LxDAQxXNQcF39Bh6KJz1UZ5ImbS-CLP6Dhb0oeAtJOtVIbZakCn57U1c8ehoY3vvNe8PYCcIFAqpLAN6WUlbPZ7U4bwGbqpR7bPG3PmCHKb0BYAtCLpjcjIULYfDjS5H84F0Yi_QRe-OotCZGT7HYmjh5N1DR0URuCjEdsf3eDImOf-eSPd3ePK7uy_Xm7mF1vS6dEGIqFSdLfcMVgXCdE4idIYWNFWgr0fTKGpSogEsg4lY12BpJ0hne9pYAxZKd7rghTV4n5_P91xxxzDF0JjSyrbOo2olcDClF6vU2-ncTvzSCnn-i5_J6Lq9roX9-omW2Xe1slAt85p4zn0ZHnY8zvgv-f8A35FBqmA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>On cooling silicon surface-barrier particle detectors</title><source>Alma/SFX Local Collection</source><creator>Calligaris, F. ; Ciuti, P. ; Gabrielli, I. ; Giacomich, R.</creator><creatorcontrib>Calligaris, F. ; Ciuti, P. ; Gabrielli, I. ; Giacomich, R. ; Univ. degli Studi, Trieste, Italy</creatorcontrib><description>The energy resolution of a surface-barrier silicon detector, thermoelectrically cooled, has been measured from 20°C to −30°C. Different thermic screens have been used in order to evidence the effect of thermic gradients inside the detector.</description><identifier>ISSN: 0029-554X</identifier><identifier>DOI: 10.1016/0029-554X(73)90184-5</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>LOW TEMPERATURE ; MEDIUM TEMPERATURE ; N46110 -Instrumentation-Radiation Detection Instruments- General Detectors &amp; Monitors ; SI SEMICONDUCTOR DETECTORS ; SURFACE BARRIER DETECTORS- ENERGY RESOLUTION ; TEMPERATURE DEPENDENCE</subject><ispartof>Nuclear instruments &amp; methods, 1973-10, Vol.112 (3), p.591-595</ispartof><rights>1973</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c333t-62ebef826e03cdc311dae618b31b438f6ba15160250ee2b6819a5e5ca29fbe013</citedby><cites>FETCH-LOGICAL-c333t-62ebef826e03cdc311dae618b31b438f6ba15160250ee2b6819a5e5ca29fbe013</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27915,27916</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/4388597$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Calligaris, F.</creatorcontrib><creatorcontrib>Ciuti, P.</creatorcontrib><creatorcontrib>Gabrielli, I.</creatorcontrib><creatorcontrib>Giacomich, R.</creatorcontrib><creatorcontrib>Univ. degli Studi, Trieste, Italy</creatorcontrib><title>On cooling silicon surface-barrier particle detectors</title><title>Nuclear instruments &amp; methods</title><description>The energy resolution of a surface-barrier silicon detector, thermoelectrically cooled, has been measured from 20°C to −30°C. Different thermic screens have been used in order to evidence the effect of thermic gradients inside the detector.</description><subject>LOW TEMPERATURE</subject><subject>MEDIUM TEMPERATURE</subject><subject>N46110 -Instrumentation-Radiation Detection Instruments- General Detectors &amp; Monitors</subject><subject>SI SEMICONDUCTOR DETECTORS</subject><subject>SURFACE BARRIER DETECTORS- ENERGY RESOLUTION</subject><subject>TEMPERATURE DEPENDENCE</subject><issn>0029-554X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1973</creationdate><recordtype>article</recordtype><recordid>eNp9kE9LxDAQxXNQcF39Bh6KJz1UZ5ImbS-CLP6Dhb0oeAtJOtVIbZakCn57U1c8ehoY3vvNe8PYCcIFAqpLAN6WUlbPZ7U4bwGbqpR7bPG3PmCHKb0BYAtCLpjcjIULYfDjS5H84F0Yi_QRe-OotCZGT7HYmjh5N1DR0URuCjEdsf3eDImOf-eSPd3ePK7uy_Xm7mF1vS6dEGIqFSdLfcMVgXCdE4idIYWNFWgr0fTKGpSogEsg4lY12BpJ0hne9pYAxZKd7rghTV4n5_P91xxxzDF0JjSyrbOo2olcDClF6vU2-ncTvzSCnn-i5_J6Lq9roX9-omW2Xe1slAt85p4zn0ZHnY8zvgv-f8A35FBqmA</recordid><startdate>19731001</startdate><enddate>19731001</enddate><creator>Calligaris, F.</creator><creator>Ciuti, P.</creator><creator>Gabrielli, I.</creator><creator>Giacomich, R.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>19731001</creationdate><title>On cooling silicon surface-barrier particle detectors</title><author>Calligaris, F. ; Ciuti, P. ; Gabrielli, I. ; Giacomich, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c333t-62ebef826e03cdc311dae618b31b438f6ba15160250ee2b6819a5e5ca29fbe013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1973</creationdate><topic>LOW TEMPERATURE</topic><topic>MEDIUM TEMPERATURE</topic><topic>N46110 -Instrumentation-Radiation Detection Instruments- General Detectors &amp; Monitors</topic><topic>SI SEMICONDUCTOR DETECTORS</topic><topic>SURFACE BARRIER DETECTORS- ENERGY RESOLUTION</topic><topic>TEMPERATURE DEPENDENCE</topic><toplevel>online_resources</toplevel><creatorcontrib>Calligaris, F.</creatorcontrib><creatorcontrib>Ciuti, P.</creatorcontrib><creatorcontrib>Gabrielli, I.</creatorcontrib><creatorcontrib>Giacomich, R.</creatorcontrib><creatorcontrib>Univ. degli Studi, Trieste, Italy</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Nuclear instruments &amp; methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Calligaris, F.</au><au>Ciuti, P.</au><au>Gabrielli, I.</au><au>Giacomich, R.</au><aucorp>Univ. degli Studi, Trieste, Italy</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On cooling silicon surface-barrier particle detectors</atitle><jtitle>Nuclear instruments &amp; methods</jtitle><date>1973-10-01</date><risdate>1973</risdate><volume>112</volume><issue>3</issue><spage>591</spage><epage>595</epage><pages>591-595</pages><issn>0029-554X</issn><abstract>The energy resolution of a surface-barrier silicon detector, thermoelectrically cooled, has been measured from 20°C to −30°C. Different thermic screens have been used in order to evidence the effect of thermic gradients inside the detector.</abstract><pub>Elsevier B.V</pub><doi>10.1016/0029-554X(73)90184-5</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0029-554X
ispartof Nuclear instruments & methods, 1973-10, Vol.112 (3), p.591-595
issn 0029-554X
language eng
recordid cdi_osti_scitechconnect_4388597
source Alma/SFX Local Collection
subjects LOW TEMPERATURE
MEDIUM TEMPERATURE
N46110 -Instrumentation-Radiation Detection Instruments- General Detectors & Monitors
SI SEMICONDUCTOR DETECTORS
SURFACE BARRIER DETECTORS- ENERGY RESOLUTION
TEMPERATURE DEPENDENCE
title On cooling silicon surface-barrier particle detectors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T07%3A21%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20cooling%20silicon%20surface-barrier%20particle%20detectors&rft.jtitle=Nuclear%20instruments%20&%20methods&rft.au=Calligaris,%20F.&rft.aucorp=Univ.%20degli%20Studi,%20Trieste,%20Italy&rft.date=1973-10-01&rft.volume=112&rft.issue=3&rft.spage=591&rft.epage=595&rft.pages=591-595&rft.issn=0029-554X&rft_id=info:doi/10.1016/0029-554X(73)90184-5&rft_dat=%3Celsevier_osti_%3E0029554X73901845%3C/elsevier_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=0029554X73901845&rfr_iscdi=true