Three-axis atomic magnetometer based on spin precession modulation
We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the pro...
Gespeichert in:
Veröffentlicht in: | Applied physics letters 2015-11, Vol.107 (18) |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 18 |
container_start_page | |
container_title | Applied physics letters |
container_volume | 107 |
creator | Huang, H. C. Dong, H. F. Hu, X. Y. Chen, L. Gao, Y. |
description | We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT. |
doi_str_mv | 10.1063/1.4935096 |
format | Article |
fullrecord | <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_22485997</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2123810811</sourcerecordid><originalsourceid>FETCH-LOGICAL-c351t-ea6a740d40a4eb456116b5aff1327d3552f6213d24d053a5d460804e31b300d23</originalsourceid><addsrcrecordid>eNpFkE9LAzEUxIMoWKsHv8GCJw9b8_KS7O5Ri_-g4KWeQzZ5a7d0NzVJQb-9KxU8zQz8GIZh7Br4ArjGO1jIBhVv9AmbAa-qEgHqUzbjnGOpGwXn7CKl7RSVQJyxh_UmEpX2q0-FzWHoXTHYj5EmS5li0dpEvghjkfb9WOwjOUqpn_IQ_GFn82Qv2Vlnd4mu_nTO3p8e18uXcvX2_Lq8X5UOFeSSrLaV5F5yK6mVSgPoVtmuAxSVR6VEpwWgF9JzhVZ5qXnNJSG0yLkXOGc3x96Qcm-S6zO5jQvjSC4bIWStmqb6p_YxfB4oZbMNhzhOw4wAgTXwGmCibo-UiyGlSJ3Zx36w8dsAN79HGjB_R-IP3VBiyg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2123810811</pqid></control><display><type>article</type><title>Three-axis atomic magnetometer based on spin precession modulation</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Huang, H. C. ; Dong, H. F. ; Hu, X. Y. ; Chen, L. ; Gao, Y.</creator><creatorcontrib>Huang, H. C. ; Dong, H. F. ; Hu, X. Y. ; Chen, L. ; Gao, Y.</creatorcontrib><description>We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.</description><identifier>ISSN: 0003-6951</identifier><identifier>EISSN: 1077-3118</identifier><identifier>DOI: 10.1063/1.4935096</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Applied physics ; BEAMS ; CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS ; Electrons ; MAGNETIC FIELDS ; Magnetic resonance ; MAGNETOMETERS ; MODULATION ; Optical properties ; OPTICAL PUMPING ; Optical rotation ; Plasma ; PRECESSION ; RADIOWAVE RADIATION ; RESONANCE ; SENSITIVITY ; SPIN ; Three axis ; VISIBLE RADIATION</subject><ispartof>Applied physics letters, 2015-11, Vol.107 (18)</ispartof><rights>2015 AIP Publishing LLC.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c351t-ea6a740d40a4eb456116b5aff1327d3552f6213d24d053a5d460804e31b300d23</citedby><cites>FETCH-LOGICAL-c351t-ea6a740d40a4eb456116b5aff1327d3552f6213d24d053a5d460804e31b300d23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/22485997$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Huang, H. C.</creatorcontrib><creatorcontrib>Dong, H. F.</creatorcontrib><creatorcontrib>Hu, X. Y.</creatorcontrib><creatorcontrib>Chen, L.</creatorcontrib><creatorcontrib>Gao, Y.</creatorcontrib><title>Three-axis atomic magnetometer based on spin precession modulation</title><title>Applied physics letters</title><description>We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.</description><subject>Applied physics</subject><subject>BEAMS</subject><subject>CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS</subject><subject>Electrons</subject><subject>MAGNETIC FIELDS</subject><subject>Magnetic resonance</subject><subject>MAGNETOMETERS</subject><subject>MODULATION</subject><subject>Optical properties</subject><subject>OPTICAL PUMPING</subject><subject>Optical rotation</subject><subject>Plasma</subject><subject>PRECESSION</subject><subject>RADIOWAVE RADIATION</subject><subject>RESONANCE</subject><subject>SENSITIVITY</subject><subject>SPIN</subject><subject>Three axis</subject><subject>VISIBLE RADIATION</subject><issn>0003-6951</issn><issn>1077-3118</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpFkE9LAzEUxIMoWKsHv8GCJw9b8_KS7O5Ri_-g4KWeQzZ5a7d0NzVJQb-9KxU8zQz8GIZh7Br4ArjGO1jIBhVv9AmbAa-qEgHqUzbjnGOpGwXn7CKl7RSVQJyxh_UmEpX2q0-FzWHoXTHYj5EmS5li0dpEvghjkfb9WOwjOUqpn_IQ_GFn82Qv2Vlnd4mu_nTO3p8e18uXcvX2_Lq8X5UOFeSSrLaV5F5yK6mVSgPoVtmuAxSVR6VEpwWgF9JzhVZ5qXnNJSG0yLkXOGc3x96Qcm-S6zO5jQvjSC4bIWStmqb6p_YxfB4oZbMNhzhOw4wAgTXwGmCibo-UiyGlSJ3Zx36w8dsAN79HGjB_R-IP3VBiyg</recordid><startdate>20151102</startdate><enddate>20151102</enddate><creator>Huang, H. C.</creator><creator>Dong, H. F.</creator><creator>Hu, X. Y.</creator><creator>Chen, L.</creator><creator>Gao, Y.</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>20151102</creationdate><title>Three-axis atomic magnetometer based on spin precession modulation</title><author>Huang, H. C. ; Dong, H. F. ; Hu, X. Y. ; Chen, L. ; Gao, Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c351t-ea6a740d40a4eb456116b5aff1327d3552f6213d24d053a5d460804e31b300d23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Applied physics</topic><topic>BEAMS</topic><topic>CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS</topic><topic>Electrons</topic><topic>MAGNETIC FIELDS</topic><topic>Magnetic resonance</topic><topic>MAGNETOMETERS</topic><topic>MODULATION</topic><topic>Optical properties</topic><topic>OPTICAL PUMPING</topic><topic>Optical rotation</topic><topic>Plasma</topic><topic>PRECESSION</topic><topic>RADIOWAVE RADIATION</topic><topic>RESONANCE</topic><topic>SENSITIVITY</topic><topic>SPIN</topic><topic>Three axis</topic><topic>VISIBLE RADIATION</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Huang, H. C.</creatorcontrib><creatorcontrib>Dong, H. F.</creatorcontrib><creatorcontrib>Hu, X. Y.</creatorcontrib><creatorcontrib>Chen, L.</creatorcontrib><creatorcontrib>Gao, Y.</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>Applied physics letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Huang, H. C.</au><au>Dong, H. F.</au><au>Hu, X. Y.</au><au>Chen, L.</au><au>Gao, Y.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Three-axis atomic magnetometer based on spin precession modulation</atitle><jtitle>Applied physics letters</jtitle><date>2015-11-02</date><risdate>2015</risdate><volume>107</volume><issue>18</issue><issn>0003-6951</issn><eissn>1077-3118</eissn><abstract>We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/1.4935096</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-6951 |
ispartof | Applied physics letters, 2015-11, Vol.107 (18) |
issn | 0003-6951 1077-3118 |
language | eng |
recordid | cdi_osti_scitechconnect_22485997 |
source | AIP Journals Complete; Alma/SFX Local Collection |
subjects | Applied physics BEAMS CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS Electrons MAGNETIC FIELDS Magnetic resonance MAGNETOMETERS MODULATION Optical properties OPTICAL PUMPING Optical rotation Plasma PRECESSION RADIOWAVE RADIATION RESONANCE SENSITIVITY SPIN Three axis VISIBLE RADIATION |
title | Three-axis atomic magnetometer based on spin precession modulation |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T11%3A43%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Three-axis%20atomic%20magnetometer%20based%20on%20spin%20precession%20modulation&rft.jtitle=Applied%20physics%20letters&rft.au=Huang,%20H.%20C.&rft.date=2015-11-02&rft.volume=107&rft.issue=18&rft.issn=0003-6951&rft.eissn=1077-3118&rft_id=info:doi/10.1063/1.4935096&rft_dat=%3Cproquest_osti_%3E2123810811%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2123810811&rft_id=info:pmid/&rfr_iscdi=true |