Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes

D-Pace has developed a compact cost-effective gamma detector system based on technology licensed from TRIUMF [1]. These photodiode detectors are convenient for detecting the presence of positron emitting radioisotopes, particularly for the case of transport of radioisotopes from a PET cyclotron to h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIP conference proceedings 2013-04, Vol.1525 (1)
Hauptverfasser: Marsland, M G, Dehnel, M P, Johansson, S, Rajander, J, Solin, O, Theroux, J, Stewart, T M, Christensen, T, Hollinger, C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title AIP conference proceedings
container_volume 1525
creator Marsland, M G
Dehnel, M P
Johansson, S
Rajander, J
Solin, O
Theroux, J
Stewart, T M
Christensen, T
Hollinger, C
description D-Pace has developed a compact cost-effective gamma detector system based on technology licensed from TRIUMF [1]. These photodiode detectors are convenient for detecting the presence of positron emitting radioisotopes, particularly for the case of transport of radioisotopes from a PET cyclotron to hotlab, or from one location to another in an automated radiochemistry processing unit. This paper describes recent calibration experiments undertaken at the Turku PET Centre for stationary and moving sources of F18 and C11 in standard setups. The practical diagnostic utility of using several of these devices to track the transport of radioisotopes from the cyclotron to hotlab is illustrated. For example, such a detector system provides: a semi-quantitative indication of total activity, speed of transport, location of any activity lost en route and effectiveness of follow-up system flushes, a means of identifying bolus break-up, feedback useful for deciding when to change out tubing.
doi_str_mv 10.1063/1.4802345
format Article
fullrecord <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_22116977</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1660054039</sourcerecordid><originalsourceid>FETCH-LOGICAL-o251t-a60824e8ba5d8a07d508d23cfadab453c1c1578937b77fafdb9d434af239cc923</originalsourceid><addsrcrecordid>eNotj81qHDEQhEWcQBZnD34DgS-5jN36G42OYbETg8EXG3xbeiSNV2Z2ejLS-GHytNFmc2qqvqKaYuxKwI2AVt2KG92BVNp8YhthjGhsK9oLtnW2A6uMFkJ39jPbADjdSK1ev7Jtzu8AIEFJ6WDD_uxwTP2CJdHEcQqc5nhWOPKABflAC0fu6TijL3w-UKGQKEQeYom-VLrmOKzjv-CRplStNL3xcoh8JH9upqGij5OdaV18zCdnppzKUmk8plJOcMFanXJ9Mcf8jX0ZcMxx-_9espf7u-fdr-bx6efD7sdjQ9KI0mALndSx69GEDsEGA12Qyg8YsNdGeeGFsZ1Ttrd2wCH0LmilcZDKee-kumTX517KJe2zT3XWwdM01XV7KYVonbU19f2cmhf6vcZc9seUfRxHnCKteS_aFsBoUE79BTlRfpY</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1660054039</pqid></control><display><type>article</type><title>Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes</title><source>AIP Journals Complete</source><creator>Marsland, M G ; Dehnel, M P ; Johansson, S ; Rajander, J ; Solin, O ; Theroux, J ; Stewart, T M ; Christensen, T ; Hollinger, C</creator><creatorcontrib>Marsland, M G ; Dehnel, M P ; Johansson, S ; Rajander, J ; Solin, O ; Theroux, J ; Stewart, T M ; Christensen, T ; Hollinger, C</creatorcontrib><description>D-Pace has developed a compact cost-effective gamma detector system based on technology licensed from TRIUMF [1]. These photodiode detectors are convenient for detecting the presence of positron emitting radioisotopes, particularly for the case of transport of radioisotopes from a PET cyclotron to hotlab, or from one location to another in an automated radiochemistry processing unit. This paper describes recent calibration experiments undertaken at the Turku PET Centre for stationary and moving sources of F18 and C11 in standard setups. The practical diagnostic utility of using several of these devices to track the transport of radioisotopes from the cyclotron to hotlab is illustrated. For example, such a detector system provides: a semi-quantitative indication of total activity, speed of transport, location of any activity lost en route and effectiveness of follow-up system flushes, a means of identifying bolus break-up, feedback useful for deciding when to change out tubing.</description><identifier>ISSN: 0094-243X</identifier><identifier>ISBN: 9780735411487</identifier><identifier>ISBN: 0735411484</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.4802345</identifier><language>eng</language><publisher>United States</publisher><subject>07 ISOTOPES AND RADIATION SOURCES ; CALIBRATION ; CARBON 11 ; CYCLOTRONS ; Devices ; Emittance ; FLUORINE 18 ; INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; PHOTODETECTORS ; Photodiode detectors ; PHOTODIODES ; POSITRON COMPUTED TOMOGRAPHY ; POSITRONS ; RADIATION MONITORING ; Radioisotopes ; RADIOLOGY AND NUCLEAR MEDICINE ; Transport</subject><ispartof>AIP conference proceedings, 2013-04, Vol.1525 (1)</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/22116977$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Marsland, M G</creatorcontrib><creatorcontrib>Dehnel, M P</creatorcontrib><creatorcontrib>Johansson, S</creatorcontrib><creatorcontrib>Rajander, J</creatorcontrib><creatorcontrib>Solin, O</creatorcontrib><creatorcontrib>Theroux, J</creatorcontrib><creatorcontrib>Stewart, T M</creatorcontrib><creatorcontrib>Christensen, T</creatorcontrib><creatorcontrib>Hollinger, C</creatorcontrib><title>Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes</title><title>AIP conference proceedings</title><description>D-Pace has developed a compact cost-effective gamma detector system based on technology licensed from TRIUMF [1]. These photodiode detectors are convenient for detecting the presence of positron emitting radioisotopes, particularly for the case of transport of radioisotopes from a PET cyclotron to hotlab, or from one location to another in an automated radiochemistry processing unit. This paper describes recent calibration experiments undertaken at the Turku PET Centre for stationary and moving sources of F18 and C11 in standard setups. The practical diagnostic utility of using several of these devices to track the transport of radioisotopes from the cyclotron to hotlab is illustrated. For example, such a detector system provides: a semi-quantitative indication of total activity, speed of transport, location of any activity lost en route and effectiveness of follow-up system flushes, a means of identifying bolus break-up, feedback useful for deciding when to change out tubing.</description><subject>07 ISOTOPES AND RADIATION SOURCES</subject><subject>CALIBRATION</subject><subject>CARBON 11</subject><subject>CYCLOTRONS</subject><subject>Devices</subject><subject>Emittance</subject><subject>FLUORINE 18</subject><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>PHOTODETECTORS</subject><subject>Photodiode detectors</subject><subject>PHOTODIODES</subject><subject>POSITRON COMPUTED TOMOGRAPHY</subject><subject>POSITRONS</subject><subject>RADIATION MONITORING</subject><subject>Radioisotopes</subject><subject>RADIOLOGY AND NUCLEAR MEDICINE</subject><subject>Transport</subject><issn>0094-243X</issn><issn>1551-7616</issn><isbn>9780735411487</isbn><isbn>0735411484</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNotj81qHDEQhEWcQBZnD34DgS-5jN36G42OYbETg8EXG3xbeiSNV2Z2ejLS-GHytNFmc2qqvqKaYuxKwI2AVt2KG92BVNp8YhthjGhsK9oLtnW2A6uMFkJ39jPbADjdSK1ev7Jtzu8AIEFJ6WDD_uxwTP2CJdHEcQqc5nhWOPKABflAC0fu6TijL3w-UKGQKEQeYom-VLrmOKzjv-CRplStNL3xcoh8JH9upqGij5OdaV18zCdnppzKUmk8plJOcMFanXJ9Mcf8jX0ZcMxx-_9espf7u-fdr-bx6efD7sdjQ9KI0mALndSx69GEDsEGA12Qyg8YsNdGeeGFsZ1Ttrd2wCH0LmilcZDKee-kumTX517KJe2zT3XWwdM01XV7KYVonbU19f2cmhf6vcZc9seUfRxHnCKteS_aFsBoUE79BTlRfpY</recordid><startdate>20130419</startdate><enddate>20130419</enddate><creator>Marsland, M G</creator><creator>Dehnel, M P</creator><creator>Johansson, S</creator><creator>Rajander, J</creator><creator>Solin, O</creator><creator>Theroux, J</creator><creator>Stewart, T M</creator><creator>Christensen, T</creator><creator>Hollinger, C</creator><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>20130419</creationdate><title>Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes</title><author>Marsland, M G ; Dehnel, M P ; Johansson, S ; Rajander, J ; Solin, O ; Theroux, J ; Stewart, T M ; Christensen, T ; Hollinger, C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-o251t-a60824e8ba5d8a07d508d23cfadab453c1c1578937b77fafdb9d434af239cc923</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>07 ISOTOPES AND RADIATION SOURCES</topic><topic>CALIBRATION</topic><topic>CARBON 11</topic><topic>CYCLOTRONS</topic><topic>Devices</topic><topic>Emittance</topic><topic>FLUORINE 18</topic><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>PHOTODETECTORS</topic><topic>Photodiode detectors</topic><topic>PHOTODIODES</topic><topic>POSITRON COMPUTED TOMOGRAPHY</topic><topic>POSITRONS</topic><topic>RADIATION MONITORING</topic><topic>Radioisotopes</topic><topic>RADIOLOGY AND NUCLEAR MEDICINE</topic><topic>Transport</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Marsland, M G</creatorcontrib><creatorcontrib>Dehnel, M P</creatorcontrib><creatorcontrib>Johansson, S</creatorcontrib><creatorcontrib>Rajander, J</creatorcontrib><creatorcontrib>Solin, O</creatorcontrib><creatorcontrib>Theroux, J</creatorcontrib><creatorcontrib>Stewart, T M</creatorcontrib><creatorcontrib>Christensen, T</creatorcontrib><creatorcontrib>Hollinger, C</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>AIP conference proceedings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marsland, M G</au><au>Dehnel, M P</au><au>Johansson, S</au><au>Rajander, J</au><au>Solin, O</au><au>Theroux, J</au><au>Stewart, T M</au><au>Christensen, T</au><au>Hollinger, C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes</atitle><jtitle>AIP conference proceedings</jtitle><date>2013-04-19</date><risdate>2013</risdate><volume>1525</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><isbn>9780735411487</isbn><isbn>0735411484</isbn><abstract>D-Pace has developed a compact cost-effective gamma detector system based on technology licensed from TRIUMF [1]. These photodiode detectors are convenient for detecting the presence of positron emitting radioisotopes, particularly for the case of transport of radioisotopes from a PET cyclotron to hotlab, or from one location to another in an automated radiochemistry processing unit. This paper describes recent calibration experiments undertaken at the Turku PET Centre for stationary and moving sources of F18 and C11 in standard setups. The practical diagnostic utility of using several of these devices to track the transport of radioisotopes from the cyclotron to hotlab is illustrated. For example, such a detector system provides: a semi-quantitative indication of total activity, speed of transport, location of any activity lost en route and effectiveness of follow-up system flushes, a means of identifying bolus break-up, feedback useful for deciding when to change out tubing.</abstract><cop>United States</cop><doi>10.1063/1.4802345</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2013-04, Vol.1525 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_osti_scitechconnect_22116977
source AIP Journals Complete
subjects 07 ISOTOPES AND RADIATION SOURCES
CALIBRATION
CARBON 11
CYCLOTRONS
Devices
Emittance
FLUORINE 18
INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
PHOTODETECTORS
Photodiode detectors
PHOTODIODES
POSITRON COMPUTED TOMOGRAPHY
POSITRONS
RADIATION MONITORING
Radioisotopes
RADIOLOGY AND NUCLEAR MEDICINE
Transport
title Calibration and operational data for a compact photodiode detector useful for monitoring the location of moving sources of positron emitting radioisotopes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T17%3A58%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration%20and%20operational%20data%20for%20a%20compact%20photodiode%20detector%20useful%20for%20monitoring%20the%20location%20of%20moving%20sources%20of%20positron%20emitting%20radioisotopes&rft.jtitle=AIP%20conference%20proceedings&rft.au=Marsland,%20M%20G&rft.date=2013-04-19&rft.volume=1525&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.isbn=9780735411487&rft.isbn_list=0735411484&rft_id=info:doi/10.1063/1.4802345&rft_dat=%3Cproquest_osti_%3E1660054039%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1660054039&rft_id=info:pmid/&rfr_iscdi=true