Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies
The feasibility of using TANDEM electrostatic particle accelerators as a linear TOF analyzer for molecular ions (TOF-AMS) is reported in this work. A specific ion source, based on a soft ionization technique commonly used in modern mass spectrometry, employing a pulsed UV-laser to desorb molecular i...
Gespeichert in:
Hauptverfasser: | , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 65 |
---|---|
container_issue | 1 |
container_start_page | 63 |
container_title | |
container_volume | 1099 |
creator | Pereira, J A M Macchione, E L A Vasconcelos, S S Added, N Tabacniks, M H Dietzsch, O Santos, W M S Luiz, A M de Castro Faria, N V |
description | The feasibility of using TANDEM electrostatic particle accelerators as a linear TOF analyzer for molecular ions (TOF-AMS) is reported in this work. A specific ion source, based on a soft ionization technique commonly used in modern mass spectrometry, employing a pulsed UV-laser to desorb molecular ions from the solid state, was built for that purpose. The current instrumentation has been used to analyze samples of CsI and C60 using the whole accelerator as a linear Time of Flight spectrometer. From the point of view of basic studies on molecular collisions, the apparatus has some unique features that allow the simultaneous discrimination of various fragmentation and charge exchange channels for different types of molecular ions. From the point of view of applied studies, the TOF-AMS technique may be able to overcome some difficulties encountered in mass spectrometry of biomolecules. |
doi_str_mv | 10.1063/1.3120118 |
format | Conference Proceeding |
fullrecord | <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_21289613</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>33921203</sourcerecordid><originalsourceid>FETCH-LOGICAL-o214t-3ceb962d154b7fe6b4efc0e069d79bdc72e614566e6a1a8fddc2fa47c5d342503</originalsourceid><addsrcrecordid>eNot0M1LwzAYBvDgB1jnDv4HAUH00JmvJs1xjE0HKztsiidLmr7dKl0zk-zgf29hnt7Lj4fneRG6p2RCieQvdMIpI5TmFyihWUZTJam8RGOtcqJ4JgbD9RVKCNEiZYJ_3qDbEL4JYVqpPEFf2_YAeN3gRdfu9hFPrYUOvInO48KEgDdHsNG7A0T_i5-260U6LTbP2DV4ZfwOcOE6sKfOeLx0fcAm4gI-8LwHv2sh3KHrxnQBxv93hN4X8-3sLV2tX5ez6Sp1jIqYcguVlqymmahUA7IS0FgCROpa6aq2ioGkIpMSpKEmb-rassYIZbOaC5YRPkIP51wXYlsG20awe-v6fihfMspyLSkf1ONZHb37OUGI5aENw97O9OBOoRxeNVjC-R_crmNo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>33921203</pqid></control><display><type>conference_proceeding</type><title>Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies</title><source>AIP Journals Complete</source><creator>Pereira, J A M ; Macchione, E L A ; Vasconcelos, S S ; Added, N ; Tabacniks, M H ; Dietzsch, O ; Santos, W M S ; Luiz, A M ; de Castro Faria, N V</creator><creatorcontrib>Pereira, J A M ; Macchione, E L A ; Vasconcelos, S S ; Added, N ; Tabacniks, M H ; Dietzsch, O ; Santos, W M S ; Luiz, A M ; de Castro Faria, N V</creatorcontrib><description>The feasibility of using TANDEM electrostatic particle accelerators as a linear TOF analyzer for molecular ions (TOF-AMS) is reported in this work. A specific ion source, based on a soft ionization technique commonly used in modern mass spectrometry, employing a pulsed UV-laser to desorb molecular ions from the solid state, was built for that purpose. The current instrumentation has been used to analyze samples of CsI and C60 using the whole accelerator as a linear Time of Flight spectrometer. From the point of view of basic studies on molecular collisions, the apparatus has some unique features that allow the simultaneous discrimination of various fragmentation and charge exchange channels for different types of molecular ions. From the point of view of applied studies, the TOF-AMS technique may be able to overcome some difficulties encountered in mass spectrometry of biomolecules.</description><identifier>ISSN: 0094-243X</identifier><identifier>ISBN: 9780735406339</identifier><identifier>ISBN: 0735406332</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.3120118</identifier><language>eng</language><publisher>United States</publisher><subject>ATOMIC AND MOLECULAR PHYSICS ; CESIUM IODIDES ; CHARGE EXCHANGE ; CURRENTS ; ELECTROSTATIC ACCELERATORS ; FULLERENES ; IONIZATION ; MASS SPECTROSCOPY ; MEV RANGE ; MOLECULAR IONS ; MOLECULE COLLISIONS ; TIME-OF-FLIGHT METHOD ; ULTRAVIOLET RADIATION</subject><ispartof>AIP conference proceedings, 2009, Vol.1099 (1), p.63-65</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/21289613$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Pereira, J A M</creatorcontrib><creatorcontrib>Macchione, E L A</creatorcontrib><creatorcontrib>Vasconcelos, S S</creatorcontrib><creatorcontrib>Added, N</creatorcontrib><creatorcontrib>Tabacniks, M H</creatorcontrib><creatorcontrib>Dietzsch, O</creatorcontrib><creatorcontrib>Santos, W M S</creatorcontrib><creatorcontrib>Luiz, A M</creatorcontrib><creatorcontrib>de Castro Faria, N V</creatorcontrib><title>Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies</title><title>AIP conference proceedings</title><description>The feasibility of using TANDEM electrostatic particle accelerators as a linear TOF analyzer for molecular ions (TOF-AMS) is reported in this work. A specific ion source, based on a soft ionization technique commonly used in modern mass spectrometry, employing a pulsed UV-laser to desorb molecular ions from the solid state, was built for that purpose. The current instrumentation has been used to analyze samples of CsI and C60 using the whole accelerator as a linear Time of Flight spectrometer. From the point of view of basic studies on molecular collisions, the apparatus has some unique features that allow the simultaneous discrimination of various fragmentation and charge exchange channels for different types of molecular ions. From the point of view of applied studies, the TOF-AMS technique may be able to overcome some difficulties encountered in mass spectrometry of biomolecules.</description><subject>ATOMIC AND MOLECULAR PHYSICS</subject><subject>CESIUM IODIDES</subject><subject>CHARGE EXCHANGE</subject><subject>CURRENTS</subject><subject>ELECTROSTATIC ACCELERATORS</subject><subject>FULLERENES</subject><subject>IONIZATION</subject><subject>MASS SPECTROSCOPY</subject><subject>MEV RANGE</subject><subject>MOLECULAR IONS</subject><subject>MOLECULE COLLISIONS</subject><subject>TIME-OF-FLIGHT METHOD</subject><subject>ULTRAVIOLET RADIATION</subject><issn>0094-243X</issn><issn>1551-7616</issn><isbn>9780735406339</isbn><isbn>0735406332</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2009</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNot0M1LwzAYBvDgB1jnDv4HAUH00JmvJs1xjE0HKztsiidLmr7dKl0zk-zgf29hnt7Lj4fneRG6p2RCieQvdMIpI5TmFyihWUZTJam8RGOtcqJ4JgbD9RVKCNEiZYJ_3qDbEL4JYVqpPEFf2_YAeN3gRdfu9hFPrYUOvInO48KEgDdHsNG7A0T_i5-260U6LTbP2DV4ZfwOcOE6sKfOeLx0fcAm4gI-8LwHv2sh3KHrxnQBxv93hN4X8-3sLV2tX5ez6Sp1jIqYcguVlqymmahUA7IS0FgCROpa6aq2ioGkIpMSpKEmb-rassYIZbOaC5YRPkIP51wXYlsG20awe-v6fihfMspyLSkf1ONZHb37OUGI5aENw97O9OBOoRxeNVjC-R_crmNo</recordid><startdate>20090101</startdate><enddate>20090101</enddate><creator>Pereira, J A M</creator><creator>Macchione, E L A</creator><creator>Vasconcelos, S S</creator><creator>Added, N</creator><creator>Tabacniks, M H</creator><creator>Dietzsch, O</creator><creator>Santos, W M S</creator><creator>Luiz, A M</creator><creator>de Castro Faria, N V</creator><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>20090101</creationdate><title>Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies</title><author>Pereira, J A M ; Macchione, E L A ; Vasconcelos, S S ; Added, N ; Tabacniks, M H ; Dietzsch, O ; Santos, W M S ; Luiz, A M ; de Castro Faria, N V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-o214t-3ceb962d154b7fe6b4efc0e069d79bdc72e614566e6a1a8fddc2fa47c5d342503</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2009</creationdate><topic>ATOMIC AND MOLECULAR PHYSICS</topic><topic>CESIUM IODIDES</topic><topic>CHARGE EXCHANGE</topic><topic>CURRENTS</topic><topic>ELECTROSTATIC ACCELERATORS</topic><topic>FULLERENES</topic><topic>IONIZATION</topic><topic>MASS SPECTROSCOPY</topic><topic>MEV RANGE</topic><topic>MOLECULAR IONS</topic><topic>MOLECULE COLLISIONS</topic><topic>TIME-OF-FLIGHT METHOD</topic><topic>ULTRAVIOLET RADIATION</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pereira, J A M</creatorcontrib><creatorcontrib>Macchione, E L A</creatorcontrib><creatorcontrib>Vasconcelos, S S</creatorcontrib><creatorcontrib>Added, N</creatorcontrib><creatorcontrib>Tabacniks, M H</creatorcontrib><creatorcontrib>Dietzsch, O</creatorcontrib><creatorcontrib>Santos, W M S</creatorcontrib><creatorcontrib>Luiz, A M</creatorcontrib><creatorcontrib>de Castro Faria, N V</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pereira, J A M</au><au>Macchione, E L A</au><au>Vasconcelos, S S</au><au>Added, N</au><au>Tabacniks, M H</au><au>Dietzsch, O</au><au>Santos, W M S</au><au>Luiz, A M</au><au>de Castro Faria, N V</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies</atitle><btitle>AIP conference proceedings</btitle><date>2009-01-01</date><risdate>2009</risdate><volume>1099</volume><issue>1</issue><spage>63</spage><epage>65</epage><pages>63-65</pages><issn>0094-243X</issn><eissn>1551-7616</eissn><isbn>9780735406339</isbn><isbn>0735406332</isbn><abstract>The feasibility of using TANDEM electrostatic particle accelerators as a linear TOF analyzer for molecular ions (TOF-AMS) is reported in this work. A specific ion source, based on a soft ionization technique commonly used in modern mass spectrometry, employing a pulsed UV-laser to desorb molecular ions from the solid state, was built for that purpose. The current instrumentation has been used to analyze samples of CsI and C60 using the whole accelerator as a linear Time of Flight spectrometer. From the point of view of basic studies on molecular collisions, the apparatus has some unique features that allow the simultaneous discrimination of various fragmentation and charge exchange channels for different types of molecular ions. From the point of view of applied studies, the TOF-AMS technique may be able to overcome some difficulties encountered in mass spectrometry of biomolecules.</abstract><cop>United States</cop><doi>10.1063/1.3120118</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2009, Vol.1099 (1), p.63-65 |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_osti_scitechconnect_21289613 |
source | AIP Journals Complete |
subjects | ATOMIC AND MOLECULAR PHYSICS CESIUM IODIDES CHARGE EXCHANGE CURRENTS ELECTROSTATIC ACCELERATORS FULLERENES IONIZATION MASS SPECTROSCOPY MEV RANGE MOLECULAR IONS MOLECULE COLLISIONS TIME-OF-FLIGHT METHOD ULTRAVIOLET RADIATION |
title | Time Of Flight Accelerator Mass Spectrometry (TOF-AMS) of Large Molecular Ions at MeV Energies |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T07%3A57%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Time%20Of%20Flight%20Accelerator%20Mass%20Spectrometry%20(TOF-AMS)%20of%20Large%20Molecular%20Ions%20at%20MeV%20Energies&rft.btitle=AIP%20conference%20proceedings&rft.au=Pereira,%20J%20A%20M&rft.date=2009-01-01&rft.volume=1099&rft.issue=1&rft.spage=63&rft.epage=65&rft.pages=63-65&rft.issn=0094-243X&rft.eissn=1551-7616&rft.isbn=9780735406339&rft.isbn_list=0735406332&rft_id=info:doi/10.1063/1.3120118&rft_dat=%3Cproquest_osti_%3E33921203%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=33921203&rft_id=info:pmid/&rfr_iscdi=true |