Particle and Gas Emissions from a Simulated Coal-Burning Household Fire Pit

An open fire was assembled with firebricks to simulate the household fire pit used in rural China, and 15 different coals from this area were burned to measure the gaseous and particulate emissions. Particle size distribution was studied with a microorifice uniform-deposit impactor (MOUDI). Over 90%...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental science & technology 2008-04, Vol.42 (7), p.2503-2508
Hauptverfasser: Tian, Linwei, Lucas, Donald, Fischer, Susan L, Lee, S. C, Hammond, S. Katharine, Koshland, Catherine P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2508
container_issue 7
container_start_page 2503
container_title Environmental science & technology
container_volume 42
creator Tian, Linwei
Lucas, Donald
Fischer, Susan L
Lee, S. C
Hammond, S. Katharine
Koshland, Catherine P
description An open fire was assembled with firebricks to simulate the household fire pit used in rural China, and 15 different coals from this area were burned to measure the gaseous and particulate emissions. Particle size distribution was studied with a microorifice uniform-deposit impactor (MOUDI). Over 90% of the particulate mass was attributed to sub-micrometer particles. The carbon balance method was used to calculate the emission factors. Emission factors for four pollutants (particulate matter, CO2, total hydrocarbons, and NO x ) were 2–4 times higher for bituminous coals than for anthracites. In past inventories of carbonaceous emissions used for climate modeling, these two types of coal were not treated separately. The dramatic emission factor difference between the two types of coal warrants attention in the future development of emission inventories.
doi_str_mv 10.1021/es0716610
format Article
fullrecord <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_21049828</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20686628</sourcerecordid><originalsourceid>FETCH-LOGICAL-a533t-4f9c1b3c042eae55a15f1715771ace6fd172f492a1c52596beb9272ee00a51a43</originalsourceid><addsrcrecordid>eNqFkU9v1DAQxS0EotvCgS-ALBBIHAIzThw7x7L9s6iVWKkFcbNmvQ51SeJiJ1L59njZ1VaCA6c5vJ-e3pvH2AuE9wgCP7gECusa4RGboRRQSC3xMZsBYFk0Zf3tgB2mdAsAogT9lB2gllA1Ws_YxZLi6G3nOA1rfk6Jn_Y-JR-GxNsYek78yvdTR6Nb83mgrvg4xcEP3_kiTMndhG7Nz3x0fOnHZ-xJS11yz3f3iH05O72eL4rLz-ef5seXBcmyHIuqbSyuSguVcOSkJJQtKpRKIVlXt2tUoq0aQWilkE29cqtGKOEcAEmkqjxir7e-IY3eJOtHZ29sGAZnRyNw00zoTL3dUncx_JxcGk0uZl3X0eBydKNAaQRV_RcUUOu6_uP46i_wNuRn5Kom_xUrLeXG7d0WsjGkFF1r7qLvKf4yCGazltmvldmXO8Np1bv1A7mbJwNvdgAlS10babA-7TkBQuRsKnPFlvNpdPd7neIPk1UlzfXyyogTfbE4-VrmsHtfsumhxL8BfwOgubNg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>230148554</pqid></control><display><type>article</type><title>Particle and Gas Emissions from a Simulated Coal-Burning Household Fire Pit</title><source>MEDLINE</source><source>American Chemical Society Journals</source><creator>Tian, Linwei ; Lucas, Donald ; Fischer, Susan L ; Lee, S. C ; Hammond, S. Katharine ; Koshland, Catherine P</creator><creatorcontrib>Tian, Linwei ; Lucas, Donald ; Fischer, Susan L ; Lee, S. C ; Hammond, S. Katharine ; Koshland, Catherine P</creatorcontrib><description>An open fire was assembled with firebricks to simulate the household fire pit used in rural China, and 15 different coals from this area were burned to measure the gaseous and particulate emissions. Particle size distribution was studied with a microorifice uniform-deposit impactor (MOUDI). Over 90% of the particulate mass was attributed to sub-micrometer particles. The carbon balance method was used to calculate the emission factors. Emission factors for four pollutants (particulate matter, CO2, total hydrocarbons, and NO x ) were 2–4 times higher for bituminous coals than for anthracites. In past inventories of carbonaceous emissions used for climate modeling, these two types of coal were not treated separately. The dramatic emission factor difference between the two types of coal warrants attention in the future development of emission inventories.</description><identifier>ISSN: 0013-936X</identifier><identifier>EISSN: 1520-5851</identifier><identifier>DOI: 10.1021/es0716610</identifier><identifier>PMID: 18504988</identifier><identifier>CODEN: ESTHAG</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>01 COAL, LIGNITE, AND PEAT ; 09 BIOMASS FUELS ; Airborne particulates ; ANTHRACITE ; Applied sciences ; Atmospheric models ; BITUMINOUS COAL ; CARBON DIOXIDE ; CARBON MONOXIDE ; CHINA ; COAL ; DISTRIBUTION ; EMISSION ; Emissions ; Environmental Measurements Methods ; Exact sciences and technology ; FIREPLACES ; Gases ; HOUSEHOLDS ; HYDROCARBONS ; INVENTORIES ; NITROGEN OXIDES ; PARTICLE SIZE ; PARTICULATES ; Pollution ; RESIDENTIAL SECTOR ; RURAL AREAS ; Simulation ; STOVES ; Studies ; WOOD FUELS</subject><ispartof>Environmental science &amp; technology, 2008-04, Vol.42 (7), p.2503-2508</ispartof><rights>Copyright © 2008 American Chemical Society</rights><rights>2008 INIST-CNRS</rights><rights>Copyright American Chemical Society Apr 1, 2008</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a533t-4f9c1b3c042eae55a15f1715771ace6fd172f492a1c52596beb9272ee00a51a43</citedby><cites>FETCH-LOGICAL-a533t-4f9c1b3c042eae55a15f1715771ace6fd172f492a1c52596beb9272ee00a51a43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/es0716610$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/es0716610$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>230,315,781,785,886,2766,27080,27928,27929,56742,56792</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=20226867$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18504988$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/21049828$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Tian, Linwei</creatorcontrib><creatorcontrib>Lucas, Donald</creatorcontrib><creatorcontrib>Fischer, Susan L</creatorcontrib><creatorcontrib>Lee, S. C</creatorcontrib><creatorcontrib>Hammond, S. Katharine</creatorcontrib><creatorcontrib>Koshland, Catherine P</creatorcontrib><title>Particle and Gas Emissions from a Simulated Coal-Burning Household Fire Pit</title><title>Environmental science &amp; technology</title><addtitle>Environ. Sci. Technol</addtitle><description>An open fire was assembled with firebricks to simulate the household fire pit used in rural China, and 15 different coals from this area were burned to measure the gaseous and particulate emissions. Particle size distribution was studied with a microorifice uniform-deposit impactor (MOUDI). Over 90% of the particulate mass was attributed to sub-micrometer particles. The carbon balance method was used to calculate the emission factors. Emission factors for four pollutants (particulate matter, CO2, total hydrocarbons, and NO x ) were 2–4 times higher for bituminous coals than for anthracites. In past inventories of carbonaceous emissions used for climate modeling, these two types of coal were not treated separately. The dramatic emission factor difference between the two types of coal warrants attention in the future development of emission inventories.</description><subject>01 COAL, LIGNITE, AND PEAT</subject><subject>09 BIOMASS FUELS</subject><subject>Airborne particulates</subject><subject>ANTHRACITE</subject><subject>Applied sciences</subject><subject>Atmospheric models</subject><subject>BITUMINOUS COAL</subject><subject>CARBON DIOXIDE</subject><subject>CARBON MONOXIDE</subject><subject>CHINA</subject><subject>COAL</subject><subject>DISTRIBUTION</subject><subject>EMISSION</subject><subject>Emissions</subject><subject>Environmental Measurements Methods</subject><subject>Exact sciences and technology</subject><subject>FIREPLACES</subject><subject>Gases</subject><subject>HOUSEHOLDS</subject><subject>HYDROCARBONS</subject><subject>INVENTORIES</subject><subject>NITROGEN OXIDES</subject><subject>PARTICLE SIZE</subject><subject>PARTICULATES</subject><subject>Pollution</subject><subject>RESIDENTIAL SECTOR</subject><subject>RURAL AREAS</subject><subject>Simulation</subject><subject>STOVES</subject><subject>Studies</subject><subject>WOOD FUELS</subject><issn>0013-936X</issn><issn>1520-5851</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkU9v1DAQxS0EotvCgS-ALBBIHAIzThw7x7L9s6iVWKkFcbNmvQ51SeJiJ1L59njZ1VaCA6c5vJ-e3pvH2AuE9wgCP7gECusa4RGboRRQSC3xMZsBYFk0Zf3tgB2mdAsAogT9lB2gllA1Ws_YxZLi6G3nOA1rfk6Jn_Y-JR-GxNsYek78yvdTR6Nb83mgrvg4xcEP3_kiTMndhG7Nz3x0fOnHZ-xJS11yz3f3iH05O72eL4rLz-ef5seXBcmyHIuqbSyuSguVcOSkJJQtKpRKIVlXt2tUoq0aQWilkE29cqtGKOEcAEmkqjxir7e-IY3eJOtHZ29sGAZnRyNw00zoTL3dUncx_JxcGk0uZl3X0eBydKNAaQRV_RcUUOu6_uP46i_wNuRn5Kom_xUrLeXG7d0WsjGkFF1r7qLvKf4yCGazltmvldmXO8Np1bv1A7mbJwNvdgAlS10babA-7TkBQuRsKnPFlvNpdPd7neIPk1UlzfXyyogTfbE4-VrmsHtfsumhxL8BfwOgubNg</recordid><startdate>20080401</startdate><enddate>20080401</enddate><creator>Tian, Linwei</creator><creator>Lucas, Donald</creator><creator>Fischer, Susan L</creator><creator>Lee, S. C</creator><creator>Hammond, S. Katharine</creator><creator>Koshland, Catherine P</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7ST</scope><scope>7T7</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><scope>SOI</scope><scope>7TV</scope><scope>7U6</scope><scope>7X8</scope><scope>OTOTI</scope></search><sort><creationdate>20080401</creationdate><title>Particle and Gas Emissions from a Simulated Coal-Burning Household Fire Pit</title><author>Tian, Linwei ; Lucas, Donald ; Fischer, Susan L ; Lee, S. C ; Hammond, S. Katharine ; Koshland, Catherine P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a533t-4f9c1b3c042eae55a15f1715771ace6fd172f492a1c52596beb9272ee00a51a43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>01 COAL, LIGNITE, AND PEAT</topic><topic>09 BIOMASS FUELS</topic><topic>Airborne particulates</topic><topic>ANTHRACITE</topic><topic>Applied sciences</topic><topic>Atmospheric models</topic><topic>BITUMINOUS COAL</topic><topic>CARBON DIOXIDE</topic><topic>CARBON MONOXIDE</topic><topic>CHINA</topic><topic>COAL</topic><topic>DISTRIBUTION</topic><topic>EMISSION</topic><topic>Emissions</topic><topic>Environmental Measurements Methods</topic><topic>Exact sciences and technology</topic><topic>FIREPLACES</topic><topic>Gases</topic><topic>HOUSEHOLDS</topic><topic>HYDROCARBONS</topic><topic>INVENTORIES</topic><topic>NITROGEN OXIDES</topic><topic>PARTICLE SIZE</topic><topic>PARTICULATES</topic><topic>Pollution</topic><topic>RESIDENTIAL SECTOR</topic><topic>RURAL AREAS</topic><topic>Simulation</topic><topic>STOVES</topic><topic>Studies</topic><topic>WOOD FUELS</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tian, Linwei</creatorcontrib><creatorcontrib>Lucas, Donald</creatorcontrib><creatorcontrib>Fischer, Susan L</creatorcontrib><creatorcontrib>Lee, S. C</creatorcontrib><creatorcontrib>Hammond, S. Katharine</creatorcontrib><creatorcontrib>Koshland, Catherine P</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environment Abstracts</collection><collection>Pollution Abstracts</collection><collection>Sustainability Science Abstracts</collection><collection>MEDLINE - Academic</collection><collection>OSTI.GOV</collection><jtitle>Environmental science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tian, Linwei</au><au>Lucas, Donald</au><au>Fischer, Susan L</au><au>Lee, S. C</au><au>Hammond, S. Katharine</au><au>Koshland, Catherine P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Particle and Gas Emissions from a Simulated Coal-Burning Household Fire Pit</atitle><jtitle>Environmental science &amp; technology</jtitle><addtitle>Environ. Sci. Technol</addtitle><date>2008-04-01</date><risdate>2008</risdate><volume>42</volume><issue>7</issue><spage>2503</spage><epage>2508</epage><pages>2503-2508</pages><issn>0013-936X</issn><eissn>1520-5851</eissn><coden>ESTHAG</coden><abstract>An open fire was assembled with firebricks to simulate the household fire pit used in rural China, and 15 different coals from this area were burned to measure the gaseous and particulate emissions. Particle size distribution was studied with a microorifice uniform-deposit impactor (MOUDI). Over 90% of the particulate mass was attributed to sub-micrometer particles. The carbon balance method was used to calculate the emission factors. Emission factors for four pollutants (particulate matter, CO2, total hydrocarbons, and NO x ) were 2–4 times higher for bituminous coals than for anthracites. In past inventories of carbonaceous emissions used for climate modeling, these two types of coal were not treated separately. The dramatic emission factor difference between the two types of coal warrants attention in the future development of emission inventories.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>18504988</pmid><doi>10.1021/es0716610</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0013-936X
ispartof Environmental science & technology, 2008-04, Vol.42 (7), p.2503-2508
issn 0013-936X
1520-5851
language eng
recordid cdi_osti_scitechconnect_21049828
source MEDLINE; American Chemical Society Journals
subjects 01 COAL, LIGNITE, AND PEAT
09 BIOMASS FUELS
Airborne particulates
ANTHRACITE
Applied sciences
Atmospheric models
BITUMINOUS COAL
CARBON DIOXIDE
CARBON MONOXIDE
CHINA
COAL
DISTRIBUTION
EMISSION
Emissions
Environmental Measurements Methods
Exact sciences and technology
FIREPLACES
Gases
HOUSEHOLDS
HYDROCARBONS
INVENTORIES
NITROGEN OXIDES
PARTICLE SIZE
PARTICULATES
Pollution
RESIDENTIAL SECTOR
RURAL AREAS
Simulation
STOVES
Studies
WOOD FUELS
title Particle and Gas Emissions from a Simulated Coal-Burning Household Fire Pit
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T07%3A47%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Particle%20and%20Gas%20Emissions%20from%20a%20Simulated%20Coal-Burning%20Household%20Fire%20Pit&rft.jtitle=Environmental%20science%20&%20technology&rft.au=Tian,%20Linwei&rft.date=2008-04-01&rft.volume=42&rft.issue=7&rft.spage=2503&rft.epage=2508&rft.pages=2503-2508&rft.issn=0013-936X&rft.eissn=1520-5851&rft.coden=ESTHAG&rft_id=info:doi/10.1021/es0716610&rft_dat=%3Cproquest_osti_%3E20686628%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=230148554&rft_id=info:pmid/18504988&rfr_iscdi=true