Performance of the ECH Transmission Lines and Launchers in DIII-D

The efficiency of the transmission line for the 110 GHz ECH system was measured in DIII-D using a low power rf source. The measured efficiency was about 10% lower than expected from theoretical analysis of the components. The launcher temperature increase during rf pulses was measured and the peak m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIP conference proceedings 2005-09, Vol.787 (1), p.407-410
Hauptverfasser: Kajiwara, K, Mui, A, Baxi, C B, Lohr, J, Gorelov, I A, Green, M T, Ponce, D, Callis, R W
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The efficiency of the transmission line for the 110 GHz ECH system was measured in DIII-D using a low power rf source. The measured efficiency was about 10% lower than expected from theoretical analysis of the components. The launcher temperature increase during rf pulses was measured and the peak mirror surface temperature was inferred from a simulation.
ISSN:0094-243X