Performance of the ECH Transmission Lines and Launchers in DIII-D
The efficiency of the transmission line for the 110 GHz ECH system was measured in DIII-D using a low power rf source. The measured efficiency was about 10% lower than expected from theoretical analysis of the components. The launcher temperature increase during rf pulses was measured and the peak m...
Gespeichert in:
Veröffentlicht in: | AIP conference proceedings 2005-09, Vol.787 (1), p.407-410 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The efficiency of the transmission line for the 110 GHz ECH system was measured in DIII-D using a low power rf source. The measured efficiency was about 10% lower than expected from theoretical analysis of the components. The launcher temperature increase during rf pulses was measured and the peak mirror surface temperature was inferred from a simulation. |
---|---|
ISSN: | 0094-243X 1551-7616 |
DOI: | 10.1063/1.2098448 |