Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy

Simplified intensity-modulated arc therapy (SIMAT) employs forward planned, conformal, and avoidance arc combinations with dynamic multileaf collimation (MLC) as a simpler alternative to other forms of intensity-modulated radiotherapy (IMRT). In this work, we compare SIMAT with 4-field (4F) and 6-fi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2004, Vol.29 (1), p.18-25
Hauptverfasser: Bauman, G, Gete, E, Chen, J.Z, Wong, E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 25
container_issue 1
container_start_page 18
container_title Medical dosimetry : official journal of the American Association of Medical Dosimetrists
container_volume 29
creator Bauman, G
Gete, E
Chen, J.Z
Wong, E
description Simplified intensity-modulated arc therapy (SIMAT) employs forward planned, conformal, and avoidance arc combinations with dynamic multileaf collimation (MLC) as a simpler alternative to other forms of intensity-modulated radiotherapy (IMRT). In this work, we compare SIMAT with 4-field (4F) and 6-field (6F) 3D conformal radiation therapy (CRT) for prostate cancer treatment. Prostate, seminal vesicle, bladder, and rectum were contoured on the CT images of 10 patients being planned for radiotherapy. Two planning target volumes (PTV) were defined: PTV1 (prostate + seminal vesicles + 1.0-cm margin) and PTV2 (prostate + 1.0-cm margin). SIMAT, 4F, and 6F plans were generated with a prescription dose of 78 Gy to prostate and 54 Gy to the seminal vesicles. Differences in the 3 techniques in terms of target and rectal coverage were compared. In addition, dose distributions of the SIMAT plans were verified with measurements in a phantom. Mean dose to PTV2 (4F, 76 Gy; 6F, 78 Gy; SIMAT, 76 Gy) and the dose delivered to 95% of the target volume (D 95) were similar between the 3-techniques. Target conformity was better with SIMAT. Mean dose and calculated NTCP for the rectum were lower for SIMAT than those for 4F and 6F plans (4F 55.6 Gy vs. 6F 49.0 Gy vs. SIMAT 42.7 Gy). Mean dose to femoral heads was lower for the 4F technique vs. 6F and SIMAT techniques (4F 44.5 Gy vs. 6F 48.9 Gy vs. SIMAT 49.5 Gy). In-phantom measurement demonstrated good agreement between the plans and SIMAT treatments delivered in phantom. We concluded that SIMAT demonstrates advantages over 4F and 6F in terms of target conformity mean rectal dose and NTCP with good reproducibility in phantom. On the basis of this analysis, we have commenced a clinical pilot study of SIMAT for prostate cancer radiotherapy.
doi_str_mv 10.1016/j.meddos.2003.09.003
format Article
fullrecord <record><control><sourceid>pubmed_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_20655470</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0958394703001523</els_id><sourcerecordid>15023389</sourcerecordid><originalsourceid>FETCH-LOGICAL-c301t-f2f223962d2d853a9724f264e12bd621dbbae6a4410958d4e62778e0fcf8e04a3</originalsourceid><addsrcrecordid>eNp9UMtKBDEQDKK46-ofiAx4nrHzmNdFEPEFCx7Ui5eQSTpslp0Hyaywf2-GWfDmpatJV6Wri5BrChkFWtxtsxaN6UPGAHgGdRbhhCxpVfJUAGOnZAl1XqW8FuWCXISwBYBcAD8nC5oD47yql-T7w7XDzlmHJnHdiF1w4yFte7PfqTG-Ka-TcYNeDYfE9j6JCzHBoNU8HnwfxtglWnUafeKVcf2Rf0nOrNoFvDriinw9P30-vqbr95e3x4d1qjnQMbXMMsbrghlmqpyrumTCskIgZY0pGDVNo7BQQtDpHCOwYGVZIVhtYxWKr8jt_G-04mTQbkS90X3XoR4lgyLPRQmRJWaWjpaDRysH71rlD5KCnAKVWzkHKqdAJdQyQpTdzLJh38Txn-iYYCTczwSMJ_449JMDjGEY5ycDpnf_b_gFltCJxw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Bauman, G ; Gete, E ; Chen, J.Z ; Wong, E</creator><creatorcontrib>Bauman, G ; Gete, E ; Chen, J.Z ; Wong, E</creatorcontrib><description>Simplified intensity-modulated arc therapy (SIMAT) employs forward planned, conformal, and avoidance arc combinations with dynamic multileaf collimation (MLC) as a simpler alternative to other forms of intensity-modulated radiotherapy (IMRT). In this work, we compare SIMAT with 4-field (4F) and 6-field (6F) 3D conformal radiation therapy (CRT) for prostate cancer treatment. Prostate, seminal vesicle, bladder, and rectum were contoured on the CT images of 10 patients being planned for radiotherapy. Two planning target volumes (PTV) were defined: PTV1 (prostate + seminal vesicles + 1.0-cm margin) and PTV2 (prostate + 1.0-cm margin). SIMAT, 4F, and 6F plans were generated with a prescription dose of 78 Gy to prostate and 54 Gy to the seminal vesicles. Differences in the 3 techniques in terms of target and rectal coverage were compared. In addition, dose distributions of the SIMAT plans were verified with measurements in a phantom. Mean dose to PTV2 (4F, 76 Gy; 6F, 78 Gy; SIMAT, 76 Gy) and the dose delivered to 95% of the target volume (D 95) were similar between the 3-techniques. Target conformity was better with SIMAT. Mean dose and calculated NTCP for the rectum were lower for SIMAT than those for 4F and 6F plans (4F 55.6 Gy vs. 6F 49.0 Gy vs. SIMAT 42.7 Gy). Mean dose to femoral heads was lower for the 4F technique vs. 6F and SIMAT techniques (4F 44.5 Gy vs. 6F 48.9 Gy vs. SIMAT 49.5 Gy). In-phantom measurement demonstrated good agreement between the plans and SIMAT treatments delivered in phantom. We concluded that SIMAT demonstrates advantages over 4F and 6F in terms of target conformity mean rectal dose and NTCP with good reproducibility in phantom. On the basis of this analysis, we have commenced a clinical pilot study of SIMAT for prostate cancer radiotherapy.</description><identifier>ISSN: 0958-3947</identifier><identifier>EISSN: 1873-4022</identifier><identifier>DOI: 10.1016/j.meddos.2003.09.003</identifier><identifier>PMID: 15023389</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>BLADDER ; COMPUTERIZED TOMOGRAPHY ; Conformal radiotherapy ; Dynamic-arc ; Film Dosimetry ; HEAD ; Humans ; Intensity-modulation ; Male ; MODULATION ; NEOPLASMS ; PATIENTS ; PHANTOMS ; Phantoms, Imaging ; PLANNING ; PROSTATE ; Prostatic Neoplasms - radiotherapy ; Quality Assurance, Health Care ; RADIATION DOSE DISTRIBUTIONS ; RADIATION DOSES ; RADIOLOGY AND NUCLEAR MEDICINE ; RADIOTHERAPY ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted - instrumentation ; Radiotherapy Planning, Computer-Assisted - methods ; Radiotherapy, Conformal - instrumentation ; Radiotherapy, Conformal - methods ; RECTUM ; Reproducibility of Results</subject><ispartof>Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 2004, Vol.29 (1), p.18-25</ispartof><rights>2004 American Association of Medical Dosimetrists</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c301t-f2f223962d2d853a9724f264e12bd621dbbae6a4410958d4e62778e0fcf8e04a3</citedby><cites>FETCH-LOGICAL-c301t-f2f223962d2d853a9724f264e12bd621dbbae6a4410958d4e62778e0fcf8e04a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.meddos.2003.09.003$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15023389$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/20655470$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Bauman, G</creatorcontrib><creatorcontrib>Gete, E</creatorcontrib><creatorcontrib>Chen, J.Z</creatorcontrib><creatorcontrib>Wong, E</creatorcontrib><title>Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy</title><title>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</title><addtitle>Med Dosim</addtitle><description>Simplified intensity-modulated arc therapy (SIMAT) employs forward planned, conformal, and avoidance arc combinations with dynamic multileaf collimation (MLC) as a simpler alternative to other forms of intensity-modulated radiotherapy (IMRT). In this work, we compare SIMAT with 4-field (4F) and 6-field (6F) 3D conformal radiation therapy (CRT) for prostate cancer treatment. Prostate, seminal vesicle, bladder, and rectum were contoured on the CT images of 10 patients being planned for radiotherapy. Two planning target volumes (PTV) were defined: PTV1 (prostate + seminal vesicles + 1.0-cm margin) and PTV2 (prostate + 1.0-cm margin). SIMAT, 4F, and 6F plans were generated with a prescription dose of 78 Gy to prostate and 54 Gy to the seminal vesicles. Differences in the 3 techniques in terms of target and rectal coverage were compared. In addition, dose distributions of the SIMAT plans were verified with measurements in a phantom. Mean dose to PTV2 (4F, 76 Gy; 6F, 78 Gy; SIMAT, 76 Gy) and the dose delivered to 95% of the target volume (D 95) were similar between the 3-techniques. Target conformity was better with SIMAT. Mean dose and calculated NTCP for the rectum were lower for SIMAT than those for 4F and 6F plans (4F 55.6 Gy vs. 6F 49.0 Gy vs. SIMAT 42.7 Gy). Mean dose to femoral heads was lower for the 4F technique vs. 6F and SIMAT techniques (4F 44.5 Gy vs. 6F 48.9 Gy vs. SIMAT 49.5 Gy). In-phantom measurement demonstrated good agreement between the plans and SIMAT treatments delivered in phantom. We concluded that SIMAT demonstrates advantages over 4F and 6F in terms of target conformity mean rectal dose and NTCP with good reproducibility in phantom. On the basis of this analysis, we have commenced a clinical pilot study of SIMAT for prostate cancer radiotherapy.</description><subject>BLADDER</subject><subject>COMPUTERIZED TOMOGRAPHY</subject><subject>Conformal radiotherapy</subject><subject>Dynamic-arc</subject><subject>Film Dosimetry</subject><subject>HEAD</subject><subject>Humans</subject><subject>Intensity-modulation</subject><subject>Male</subject><subject>MODULATION</subject><subject>NEOPLASMS</subject><subject>PATIENTS</subject><subject>PHANTOMS</subject><subject>Phantoms, Imaging</subject><subject>PLANNING</subject><subject>PROSTATE</subject><subject>Prostatic Neoplasms - radiotherapy</subject><subject>Quality Assurance, Health Care</subject><subject>RADIATION DOSE DISTRIBUTIONS</subject><subject>RADIATION DOSES</subject><subject>RADIOLOGY AND NUCLEAR MEDICINE</subject><subject>RADIOTHERAPY</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy Planning, Computer-Assisted - instrumentation</subject><subject>Radiotherapy Planning, Computer-Assisted - methods</subject><subject>Radiotherapy, Conformal - instrumentation</subject><subject>Radiotherapy, Conformal - methods</subject><subject>RECTUM</subject><subject>Reproducibility of Results</subject><issn>0958-3947</issn><issn>1873-4022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9UMtKBDEQDKK46-ofiAx4nrHzmNdFEPEFCx7Ui5eQSTpslp0Hyaywf2-GWfDmpatJV6Wri5BrChkFWtxtsxaN6UPGAHgGdRbhhCxpVfJUAGOnZAl1XqW8FuWCXISwBYBcAD8nC5oD47yql-T7w7XDzlmHJnHdiF1w4yFte7PfqTG-Ka-TcYNeDYfE9j6JCzHBoNU8HnwfxtglWnUafeKVcf2Rf0nOrNoFvDriinw9P30-vqbr95e3x4d1qjnQMbXMMsbrghlmqpyrumTCskIgZY0pGDVNo7BQQtDpHCOwYGVZIVhtYxWKr8jt_G-04mTQbkS90X3XoR4lgyLPRQmRJWaWjpaDRysH71rlD5KCnAKVWzkHKqdAJdQyQpTdzLJh38Txn-iYYCTczwSMJ_449JMDjGEY5ycDpnf_b_gFltCJxw</recordid><startdate>2004</startdate><enddate>2004</enddate><creator>Bauman, G</creator><creator>Gete, E</creator><creator>Chen, J.Z</creator><creator>Wong, E</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>2004</creationdate><title>Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy</title><author>Bauman, G ; Gete, E ; Chen, J.Z ; Wong, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c301t-f2f223962d2d853a9724f264e12bd621dbbae6a4410958d4e62778e0fcf8e04a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>BLADDER</topic><topic>COMPUTERIZED TOMOGRAPHY</topic><topic>Conformal radiotherapy</topic><topic>Dynamic-arc</topic><topic>Film Dosimetry</topic><topic>HEAD</topic><topic>Humans</topic><topic>Intensity-modulation</topic><topic>Male</topic><topic>MODULATION</topic><topic>NEOPLASMS</topic><topic>PATIENTS</topic><topic>PHANTOMS</topic><topic>Phantoms, Imaging</topic><topic>PLANNING</topic><topic>PROSTATE</topic><topic>Prostatic Neoplasms - radiotherapy</topic><topic>Quality Assurance, Health Care</topic><topic>RADIATION DOSE DISTRIBUTIONS</topic><topic>RADIATION DOSES</topic><topic>RADIOLOGY AND NUCLEAR MEDICINE</topic><topic>RADIOTHERAPY</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy Planning, Computer-Assisted - instrumentation</topic><topic>Radiotherapy Planning, Computer-Assisted - methods</topic><topic>Radiotherapy, Conformal - instrumentation</topic><topic>Radiotherapy, Conformal - methods</topic><topic>RECTUM</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bauman, G</creatorcontrib><creatorcontrib>Gete, E</creatorcontrib><creatorcontrib>Chen, J.Z</creatorcontrib><creatorcontrib>Wong, E</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bauman, G</au><au>Gete, E</au><au>Chen, J.Z</au><au>Wong, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy</atitle><jtitle>Medical dosimetry : official journal of the American Association of Medical Dosimetrists</jtitle><addtitle>Med Dosim</addtitle><date>2004</date><risdate>2004</risdate><volume>29</volume><issue>1</issue><spage>18</spage><epage>25</epage><pages>18-25</pages><issn>0958-3947</issn><eissn>1873-4022</eissn><abstract>Simplified intensity-modulated arc therapy (SIMAT) employs forward planned, conformal, and avoidance arc combinations with dynamic multileaf collimation (MLC) as a simpler alternative to other forms of intensity-modulated radiotherapy (IMRT). In this work, we compare SIMAT with 4-field (4F) and 6-field (6F) 3D conformal radiation therapy (CRT) for prostate cancer treatment. Prostate, seminal vesicle, bladder, and rectum were contoured on the CT images of 10 patients being planned for radiotherapy. Two planning target volumes (PTV) were defined: PTV1 (prostate + seminal vesicles + 1.0-cm margin) and PTV2 (prostate + 1.0-cm margin). SIMAT, 4F, and 6F plans were generated with a prescription dose of 78 Gy to prostate and 54 Gy to the seminal vesicles. Differences in the 3 techniques in terms of target and rectal coverage were compared. In addition, dose distributions of the SIMAT plans were verified with measurements in a phantom. Mean dose to PTV2 (4F, 76 Gy; 6F, 78 Gy; SIMAT, 76 Gy) and the dose delivered to 95% of the target volume (D 95) were similar between the 3-techniques. Target conformity was better with SIMAT. Mean dose and calculated NTCP for the rectum were lower for SIMAT than those for 4F and 6F plans (4F 55.6 Gy vs. 6F 49.0 Gy vs. SIMAT 42.7 Gy). Mean dose to femoral heads was lower for the 4F technique vs. 6F and SIMAT techniques (4F 44.5 Gy vs. 6F 48.9 Gy vs. SIMAT 49.5 Gy). In-phantom measurement demonstrated good agreement between the plans and SIMAT treatments delivered in phantom. We concluded that SIMAT demonstrates advantages over 4F and 6F in terms of target conformity mean rectal dose and NTCP with good reproducibility in phantom. On the basis of this analysis, we have commenced a clinical pilot study of SIMAT for prostate cancer radiotherapy.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>15023389</pmid><doi>10.1016/j.meddos.2003.09.003</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0958-3947
ispartof Medical dosimetry : official journal of the American Association of Medical Dosimetrists, 2004, Vol.29 (1), p.18-25
issn 0958-3947
1873-4022
language eng
recordid cdi_osti_scitechconnect_20655470
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects BLADDER
COMPUTERIZED TOMOGRAPHY
Conformal radiotherapy
Dynamic-arc
Film Dosimetry
HEAD
Humans
Intensity-modulation
Male
MODULATION
NEOPLASMS
PATIENTS
PHANTOMS
Phantoms, Imaging
PLANNING
PROSTATE
Prostatic Neoplasms - radiotherapy
Quality Assurance, Health Care
RADIATION DOSE DISTRIBUTIONS
RADIATION DOSES
RADIOLOGY AND NUCLEAR MEDICINE
RADIOTHERAPY
Radiotherapy Dosage
Radiotherapy Planning, Computer-Assisted - instrumentation
Radiotherapy Planning, Computer-Assisted - methods
Radiotherapy, Conformal - instrumentation
Radiotherapy, Conformal - methods
RECTUM
Reproducibility of Results
title Simplified intensity-modulated arc therapy for dose escalated prostate cancer radiotherapy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T13%3A54%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simplified%20intensity-modulated%20arc%20therapy%20for%20dose%20escalated%20prostate%20cancer%20radiotherapy&rft.jtitle=Medical%20dosimetry%20:%20official%20journal%20of%20the%20American%20Association%20of%20Medical%20Dosimetrists&rft.au=Bauman,%20G&rft.date=2004&rft.volume=29&rft.issue=1&rft.spage=18&rft.epage=25&rft.pages=18-25&rft.issn=0958-3947&rft.eissn=1873-4022&rft_id=info:doi/10.1016/j.meddos.2003.09.003&rft_dat=%3Cpubmed_osti_%3E15023389%3C/pubmed_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/15023389&rft_els_id=S0958394703001523&rfr_iscdi=true