Improving the measurement sensitivity of the Canadian Penning Trap mass spectrometer through PI-ICR

For the past two decades the Canadian Penning Trap mass spectrometer (CPT) has been utilized to study various disciplines of nuclear physics through precision mass measurements. Since moving to the Californium Rare Isotope Breeder Upgrade (CARIBU) facility, the CPT experimental program has focused o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms Beam interactions with materials and atoms, 2020-01, Vol.463 (C), p.491-495
Hauptverfasser: Orford, R., Clark, J.A., Savard, G., Aprahamian, A., Buchinger, F., Burkey, M.T., Gorelov, D.A., Klimes, J.W., Morgan, G.E., Nystrom, A., Porter, W.S., Ray, D., Sharma, K.S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 495
container_issue C
container_start_page 491
container_title Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms
container_volume 463
creator Orford, R.
Clark, J.A.
Savard, G.
Aprahamian, A.
Buchinger, F.
Burkey, M.T.
Gorelov, D.A.
Klimes, J.W.
Morgan, G.E.
Nystrom, A.
Porter, W.S.
Ray, D.
Sharma, K.S.
description For the past two decades the Canadian Penning Trap mass spectrometer (CPT) has been utilized to study various disciplines of nuclear physics through precision mass measurements. Since moving to the Californium Rare Isotope Breeder Upgrade (CARIBU) facility, the CPT experimental program has focused on neutron-rich nuclei whose masses may play an important role in the astrophysical r process. Through a recent upgrade of the detector system, the phase-imaging ion-cyclotron-resonance (PI-ICR) technique has been successfully implemented. This method offers several benefits which drastically improve the experimental sensitivity of the CPT to the most neutron-rich nuclei produced at CARIBU. Here we describe the PI-ICR procedure at the CPT, give an overview of the systematic sources of uncertainty in the system, and provide new mass results for 142I, 146La, and 163Gd which were made possible through this upgrade.
doi_str_mv 10.1016/j.nimb.2019.04.016
format Article
fullrecord <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1776886</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0168583X19302009</els_id><sourcerecordid>S0168583X19302009</sourcerecordid><originalsourceid>FETCH-LOGICAL-c437t-8a53950fe4b2d88cc48b1ccdbca8ee70ec14000f20c18ac3b507c65ccc0174b73</originalsourceid><addsrcrecordid>eNp9kF9LwzAUxYMoOKdfwKfge2vSpm0Gvkjxz2DgkAm-hfT2dsuwaUmygd_e1PlsXgLnnt_hcAi55SzljJf3-9SavkkzxhcpE2mUzsiMyypLFoUU52QWFZkUMv-8JFfe71l8RV7MCCz70Q1HY7c07JD2qP3BYY82UI_Wm2COJnzTofs919rq1mhL12jtxGycHmmvvad-RAhu6DGgi143HLY7ul4my_r9mlx0-svjzd8_Jx_PT5v6NVm9vSzrx1UCIq9CInWRLwrWoWiyVkoAIRsO0DagJWLFELiItbuMAZca8qZgFZQFADBeiabK5-TulDv4YJQHExB2MFgbmyleVaWUZTRlJxO4wXuHnRqd6bX7VpypaUu1V9OWatpSMaGiFKGHE4Sx_tGgm9LRArbGTeHtYP7DfwDrXH7_</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Improving the measurement sensitivity of the Canadian Penning Trap mass spectrometer through PI-ICR</title><source>Elsevier ScienceDirect Journals</source><creator>Orford, R. ; Clark, J.A. ; Savard, G. ; Aprahamian, A. ; Buchinger, F. ; Burkey, M.T. ; Gorelov, D.A. ; Klimes, J.W. ; Morgan, G.E. ; Nystrom, A. ; Porter, W.S. ; Ray, D. ; Sharma, K.S.</creator><creatorcontrib>Orford, R. ; Clark, J.A. ; Savard, G. ; Aprahamian, A. ; Buchinger, F. ; Burkey, M.T. ; Gorelov, D.A. ; Klimes, J.W. ; Morgan, G.E. ; Nystrom, A. ; Porter, W.S. ; Ray, D. ; Sharma, K.S.</creatorcontrib><description>For the past two decades the Canadian Penning Trap mass spectrometer (CPT) has been utilized to study various disciplines of nuclear physics through precision mass measurements. Since moving to the Californium Rare Isotope Breeder Upgrade (CARIBU) facility, the CPT experimental program has focused on neutron-rich nuclei whose masses may play an important role in the astrophysical r process. Through a recent upgrade of the detector system, the phase-imaging ion-cyclotron-resonance (PI-ICR) technique has been successfully implemented. This method offers several benefits which drastically improve the experimental sensitivity of the CPT to the most neutron-rich nuclei produced at CARIBU. Here we describe the PI-ICR procedure at the CPT, give an overview of the systematic sources of uncertainty in the system, and provide new mass results for 142I, 146La, and 163Gd which were made possible through this upgrade.</description><identifier>ISSN: 0168-583X</identifier><identifier>EISSN: 1872-9584</identifier><identifier>DOI: 10.1016/j.nimb.2019.04.016</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Neutron-rich ; Nuclear masses ; Penning trap ; Phase-imaging</subject><ispartof>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms, 2020-01, Vol.463 (C), p.491-495</ispartof><rights>2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c437t-8a53950fe4b2d88cc48b1ccdbca8ee70ec14000f20c18ac3b507c65ccc0174b73</citedby><cites>FETCH-LOGICAL-c437t-8a53950fe4b2d88cc48b1ccdbca8ee70ec14000f20c18ac3b507c65ccc0174b73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0168583X19302009$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,776,780,881,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/1776886$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Orford, R.</creatorcontrib><creatorcontrib>Clark, J.A.</creatorcontrib><creatorcontrib>Savard, G.</creatorcontrib><creatorcontrib>Aprahamian, A.</creatorcontrib><creatorcontrib>Buchinger, F.</creatorcontrib><creatorcontrib>Burkey, M.T.</creatorcontrib><creatorcontrib>Gorelov, D.A.</creatorcontrib><creatorcontrib>Klimes, J.W.</creatorcontrib><creatorcontrib>Morgan, G.E.</creatorcontrib><creatorcontrib>Nystrom, A.</creatorcontrib><creatorcontrib>Porter, W.S.</creatorcontrib><creatorcontrib>Ray, D.</creatorcontrib><creatorcontrib>Sharma, K.S.</creatorcontrib><title>Improving the measurement sensitivity of the Canadian Penning Trap mass spectrometer through PI-ICR</title><title>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms</title><description>For the past two decades the Canadian Penning Trap mass spectrometer (CPT) has been utilized to study various disciplines of nuclear physics through precision mass measurements. Since moving to the Californium Rare Isotope Breeder Upgrade (CARIBU) facility, the CPT experimental program has focused on neutron-rich nuclei whose masses may play an important role in the astrophysical r process. Through a recent upgrade of the detector system, the phase-imaging ion-cyclotron-resonance (PI-ICR) technique has been successfully implemented. This method offers several benefits which drastically improve the experimental sensitivity of the CPT to the most neutron-rich nuclei produced at CARIBU. Here we describe the PI-ICR procedure at the CPT, give an overview of the systematic sources of uncertainty in the system, and provide new mass results for 142I, 146La, and 163Gd which were made possible through this upgrade.</description><subject>Neutron-rich</subject><subject>Nuclear masses</subject><subject>Penning trap</subject><subject>Phase-imaging</subject><issn>0168-583X</issn><issn>1872-9584</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp9kF9LwzAUxYMoOKdfwKfge2vSpm0Gvkjxz2DgkAm-hfT2dsuwaUmygd_e1PlsXgLnnt_hcAi55SzljJf3-9SavkkzxhcpE2mUzsiMyypLFoUU52QWFZkUMv-8JFfe71l8RV7MCCz70Q1HY7c07JD2qP3BYY82UI_Wm2COJnzTofs919rq1mhL12jtxGycHmmvvad-RAhu6DGgi143HLY7ul4my_r9mlx0-svjzd8_Jx_PT5v6NVm9vSzrx1UCIq9CInWRLwrWoWiyVkoAIRsO0DagJWLFELiItbuMAZca8qZgFZQFADBeiabK5-TulDv4YJQHExB2MFgbmyleVaWUZTRlJxO4wXuHnRqd6bX7VpypaUu1V9OWatpSMaGiFKGHE4Sx_tGgm9LRArbGTeHtYP7DfwDrXH7_</recordid><startdate>20200115</startdate><enddate>20200115</enddate><creator>Orford, R.</creator><creator>Clark, J.A.</creator><creator>Savard, G.</creator><creator>Aprahamian, A.</creator><creator>Buchinger, F.</creator><creator>Burkey, M.T.</creator><creator>Gorelov, D.A.</creator><creator>Klimes, J.W.</creator><creator>Morgan, G.E.</creator><creator>Nystrom, A.</creator><creator>Porter, W.S.</creator><creator>Ray, D.</creator><creator>Sharma, K.S.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>20200115</creationdate><title>Improving the measurement sensitivity of the Canadian Penning Trap mass spectrometer through PI-ICR</title><author>Orford, R. ; Clark, J.A. ; Savard, G. ; Aprahamian, A. ; Buchinger, F. ; Burkey, M.T. ; Gorelov, D.A. ; Klimes, J.W. ; Morgan, G.E. ; Nystrom, A. ; Porter, W.S. ; Ray, D. ; Sharma, K.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c437t-8a53950fe4b2d88cc48b1ccdbca8ee70ec14000f20c18ac3b507c65ccc0174b73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Neutron-rich</topic><topic>Nuclear masses</topic><topic>Penning trap</topic><topic>Phase-imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Orford, R.</creatorcontrib><creatorcontrib>Clark, J.A.</creatorcontrib><creatorcontrib>Savard, G.</creatorcontrib><creatorcontrib>Aprahamian, A.</creatorcontrib><creatorcontrib>Buchinger, F.</creatorcontrib><creatorcontrib>Burkey, M.T.</creatorcontrib><creatorcontrib>Gorelov, D.A.</creatorcontrib><creatorcontrib>Klimes, J.W.</creatorcontrib><creatorcontrib>Morgan, G.E.</creatorcontrib><creatorcontrib>Nystrom, A.</creatorcontrib><creatorcontrib>Porter, W.S.</creatorcontrib><creatorcontrib>Ray, D.</creatorcontrib><creatorcontrib>Sharma, K.S.</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Orford, R.</au><au>Clark, J.A.</au><au>Savard, G.</au><au>Aprahamian, A.</au><au>Buchinger, F.</au><au>Burkey, M.T.</au><au>Gorelov, D.A.</au><au>Klimes, J.W.</au><au>Morgan, G.E.</au><au>Nystrom, A.</au><au>Porter, W.S.</au><au>Ray, D.</au><au>Sharma, K.S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Improving the measurement sensitivity of the Canadian Penning Trap mass spectrometer through PI-ICR</atitle><jtitle>Nuclear instruments &amp; methods in physics research. Section B, Beam interactions with materials and atoms</jtitle><date>2020-01-15</date><risdate>2020</risdate><volume>463</volume><issue>C</issue><spage>491</spage><epage>495</epage><pages>491-495</pages><issn>0168-583X</issn><eissn>1872-9584</eissn><abstract>For the past two decades the Canadian Penning Trap mass spectrometer (CPT) has been utilized to study various disciplines of nuclear physics through precision mass measurements. Since moving to the Californium Rare Isotope Breeder Upgrade (CARIBU) facility, the CPT experimental program has focused on neutron-rich nuclei whose masses may play an important role in the astrophysical r process. Through a recent upgrade of the detector system, the phase-imaging ion-cyclotron-resonance (PI-ICR) technique has been successfully implemented. This method offers several benefits which drastically improve the experimental sensitivity of the CPT to the most neutron-rich nuclei produced at CARIBU. Here we describe the PI-ICR procedure at the CPT, give an overview of the systematic sources of uncertainty in the system, and provide new mass results for 142I, 146La, and 163Gd which were made possible through this upgrade.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><doi>10.1016/j.nimb.2019.04.016</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0168-583X
ispartof Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 2020-01, Vol.463 (C), p.491-495
issn 0168-583X
1872-9584
language eng
recordid cdi_osti_scitechconnect_1776886
source Elsevier ScienceDirect Journals
subjects Neutron-rich
Nuclear masses
Penning trap
Phase-imaging
title Improving the measurement sensitivity of the Canadian Penning Trap mass spectrometer through PI-ICR
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T21%3A27%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Improving%20the%20measurement%20sensitivity%20of%20the%20Canadian%20Penning%20Trap%20mass%20spectrometer%20through%20PI-ICR&rft.jtitle=Nuclear%20instruments%20&%20methods%20in%20physics%20research.%20Section%20B,%20Beam%20interactions%20with%20materials%20and%20atoms&rft.au=Orford,%20R.&rft.date=2020-01-15&rft.volume=463&rft.issue=C&rft.spage=491&rft.epage=495&rft.pages=491-495&rft.issn=0168-583X&rft.eissn=1872-9584&rft_id=info:doi/10.1016/j.nimb.2019.04.016&rft_dat=%3Celsevier_osti_%3ES0168583X19302009%3C/elsevier_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0168583X19302009&rfr_iscdi=true