Design and characterization of zero magnetic field chambers for high efficiency neutron polarization transport
Several methods of polarized neutron scattering call for a zero magnetic field (ZF) region to reduce magnetic field integral aberrations while preserving the neutron polarization. Though the design for large angle neutron scattering has been presented in various places, the design characterization a...
Gespeichert in:
Veröffentlicht in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2019-10, Vol.940 (C), p.174-180 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 180 |
---|---|
container_issue | C |
container_start_page | 174 |
container_title | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |
container_volume | 940 |
creator | Dadisman, Ryan Shen, Jiazhou Feng, Hao Crow, Lowell Jiang, Chenyang Wang, Tianhao Zhang, Yuxuan Bilheux, Hassina Parnell, Steven R. Pynn, Roger Li, Fankang |
description | Several methods of polarized neutron scattering call for a zero magnetic field (ZF) region to reduce magnetic field integral aberrations while preserving the neutron polarization. Though the design for large angle neutron scattering has been presented in various places, the design characterization and tuning has not been discussed before. In this report, the tuning procedure will be discussed with both neutron polarization transport method and utilization of fluxgate magnetometers. As a tuning procedure, polarized neutrons are sensitive to any local field distortions along all trajectories within the beam, but the process is slow. With fluxgates, the entire beam region cannot be accessed simultaneously, but very fast and precise measurements can be made in accessible regions of interest. Consequently, we would like to benchmark the usage of fluxgates as a fast tuning probe compared with polarization measurements made with neutrons. Polarization transport results for tuned ZF chambers, up to 2.25 m in length, are presented. |
doi_str_mv | 10.1016/j.nima.2019.05.092 |
format | Article |
fullrecord | <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1542231</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0168900219307648</els_id><sourcerecordid>S0168900219307648</sourcerecordid><originalsourceid>FETCH-LOGICAL-c371t-8fc036a436227a9caf873ac442249920d52dd6f58009428ab1c56cb5a254239c3</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKt_wFPwvmuS_Qx4kfoJBS96DunspE1pk5JEof31Zq14dC5zed6XmYeQa85Kznh7uy6d3epSMC5L1pRMihMy4X0nCtl07SmZZKgvJGPinFzEuGZ5ZNdPiHvAaJeOajdQWOmgIWGwB52sd9QbesDg6VYvHSYL1Fjc_HDbBYZIjQ90ZZcrisZYsOhgTx1-ppCzO7_Rf0UpaBd3PqRLcmb0JuLV756Sj6fH99lLMX97fp3dzwuoOp6K3gCrWl1XrRCdlqBN31Ua6lqIWkrBhkYMQ2uaPn9Ri14vODQtLBotmlpUEqopuTn2-pisimATwgq8cwhJ8QyJimdIHCEIPsaARu1Cthj2ijM1alVrNWpVo1bFGpW15tDdMYT5_C-LYWzPn-Ngw1g-ePtf_BsDXYKQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Design and characterization of zero magnetic field chambers for high efficiency neutron polarization transport</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><creator>Dadisman, Ryan ; Shen, Jiazhou ; Feng, Hao ; Crow, Lowell ; Jiang, Chenyang ; Wang, Tianhao ; Zhang, Yuxuan ; Bilheux, Hassina ; Parnell, Steven R. ; Pynn, Roger ; Li, Fankang</creator><creatorcontrib>Dadisman, Ryan ; Shen, Jiazhou ; Feng, Hao ; Crow, Lowell ; Jiang, Chenyang ; Wang, Tianhao ; Zhang, Yuxuan ; Bilheux, Hassina ; Parnell, Steven R. ; Pynn, Roger ; Li, Fankang ; Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)</creatorcontrib><description>Several methods of polarized neutron scattering call for a zero magnetic field (ZF) region to reduce magnetic field integral aberrations while preserving the neutron polarization. Though the design for large angle neutron scattering has been presented in various places, the design characterization and tuning has not been discussed before. In this report, the tuning procedure will be discussed with both neutron polarization transport method and utilization of fluxgate magnetometers. As a tuning procedure, polarized neutrons are sensitive to any local field distortions along all trajectories within the beam, but the process is slow. With fluxgates, the entire beam region cannot be accessed simultaneously, but very fast and precise measurements can be made in accessible regions of interest. Consequently, we would like to benchmark the usage of fluxgates as a fast tuning probe compared with polarization measurements made with neutrons. Polarization transport results for tuned ZF chambers, up to 2.25 m in length, are presented.</description><identifier>ISSN: 0168-9002</identifier><identifier>EISSN: 1872-9576</identifier><identifier>DOI: 10.1016/j.nima.2019.05.092</identifier><language>eng</language><publisher>United States: Elsevier B.V</publisher><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; Large-angle neutron scattering ; Larmor labeling ; Magnetic Wollaston prisms ; Polarization transport ; Small-angle neutron scattering ; Zero magnetic field</subject><ispartof>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2019-10, Vol.940 (C), p.174-180</ispartof><rights>2019 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c371t-8fc036a436227a9caf873ac442249920d52dd6f58009428ab1c56cb5a254239c3</citedby><cites>FETCH-LOGICAL-c371t-8fc036a436227a9caf873ac442249920d52dd6f58009428ab1c56cb5a254239c3</cites><orcidid>0000000188590102 ; 000000025212879X ; 0000000200831408 ; 0000000185742449</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.nima.2019.05.092$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,778,782,883,3539,27907,27908,45978</link.rule.ids><backlink>$$Uhttps://www.osti.gov/servlets/purl/1542231$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Dadisman, Ryan</creatorcontrib><creatorcontrib>Shen, Jiazhou</creatorcontrib><creatorcontrib>Feng, Hao</creatorcontrib><creatorcontrib>Crow, Lowell</creatorcontrib><creatorcontrib>Jiang, Chenyang</creatorcontrib><creatorcontrib>Wang, Tianhao</creatorcontrib><creatorcontrib>Zhang, Yuxuan</creatorcontrib><creatorcontrib>Bilheux, Hassina</creatorcontrib><creatorcontrib>Parnell, Steven R.</creatorcontrib><creatorcontrib>Pynn, Roger</creatorcontrib><creatorcontrib>Li, Fankang</creatorcontrib><creatorcontrib>Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)</creatorcontrib><title>Design and characterization of zero magnetic field chambers for high efficiency neutron polarization transport</title><title>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</title><description>Several methods of polarized neutron scattering call for a zero magnetic field (ZF) region to reduce magnetic field integral aberrations while preserving the neutron polarization. Though the design for large angle neutron scattering has been presented in various places, the design characterization and tuning has not been discussed before. In this report, the tuning procedure will be discussed with both neutron polarization transport method and utilization of fluxgate magnetometers. As a tuning procedure, polarized neutrons are sensitive to any local field distortions along all trajectories within the beam, but the process is slow. With fluxgates, the entire beam region cannot be accessed simultaneously, but very fast and precise measurements can be made in accessible regions of interest. Consequently, we would like to benchmark the usage of fluxgates as a fast tuning probe compared with polarization measurements made with neutrons. Polarization transport results for tuned ZF chambers, up to 2.25 m in length, are presented.</description><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>Large-angle neutron scattering</subject><subject>Larmor labeling</subject><subject>Magnetic Wollaston prisms</subject><subject>Polarization transport</subject><subject>Small-angle neutron scattering</subject><subject>Zero magnetic field</subject><issn>0168-9002</issn><issn>1872-9576</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMoWKt_wFPwvmuS_Qx4kfoJBS96DunspE1pk5JEof31Zq14dC5zed6XmYeQa85Kznh7uy6d3epSMC5L1pRMihMy4X0nCtl07SmZZKgvJGPinFzEuGZ5ZNdPiHvAaJeOajdQWOmgIWGwB52sd9QbesDg6VYvHSYL1Fjc_HDbBYZIjQ90ZZcrisZYsOhgTx1-ppCzO7_Rf0UpaBd3PqRLcmb0JuLV756Sj6fH99lLMX97fp3dzwuoOp6K3gCrWl1XrRCdlqBN31Ua6lqIWkrBhkYMQ2uaPn9Ri14vODQtLBotmlpUEqopuTn2-pisimATwgq8cwhJ8QyJimdIHCEIPsaARu1Cthj2ijM1alVrNWpVo1bFGpW15tDdMYT5_C-LYWzPn-Ngw1g-ePtf_BsDXYKQ</recordid><startdate>20191001</startdate><enddate>20191001</enddate><creator>Dadisman, Ryan</creator><creator>Shen, Jiazhou</creator><creator>Feng, Hao</creator><creator>Crow, Lowell</creator><creator>Jiang, Chenyang</creator><creator>Wang, Tianhao</creator><creator>Zhang, Yuxuan</creator><creator>Bilheux, Hassina</creator><creator>Parnell, Steven R.</creator><creator>Pynn, Roger</creator><creator>Li, Fankang</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OIOZB</scope><scope>OTOTI</scope><orcidid>https://orcid.org/0000000188590102</orcidid><orcidid>https://orcid.org/000000025212879X</orcidid><orcidid>https://orcid.org/0000000200831408</orcidid><orcidid>https://orcid.org/0000000185742449</orcidid></search><sort><creationdate>20191001</creationdate><title>Design and characterization of zero magnetic field chambers for high efficiency neutron polarization transport</title><author>Dadisman, Ryan ; Shen, Jiazhou ; Feng, Hao ; Crow, Lowell ; Jiang, Chenyang ; Wang, Tianhao ; Zhang, Yuxuan ; Bilheux, Hassina ; Parnell, Steven R. ; Pynn, Roger ; Li, Fankang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c371t-8fc036a436227a9caf873ac442249920d52dd6f58009428ab1c56cb5a254239c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>Large-angle neutron scattering</topic><topic>Larmor labeling</topic><topic>Magnetic Wollaston prisms</topic><topic>Polarization transport</topic><topic>Small-angle neutron scattering</topic><topic>Zero magnetic field</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dadisman, Ryan</creatorcontrib><creatorcontrib>Shen, Jiazhou</creatorcontrib><creatorcontrib>Feng, Hao</creatorcontrib><creatorcontrib>Crow, Lowell</creatorcontrib><creatorcontrib>Jiang, Chenyang</creatorcontrib><creatorcontrib>Wang, Tianhao</creatorcontrib><creatorcontrib>Zhang, Yuxuan</creatorcontrib><creatorcontrib>Bilheux, Hassina</creatorcontrib><creatorcontrib>Parnell, Steven R.</creatorcontrib><creatorcontrib>Pynn, Roger</creatorcontrib><creatorcontrib>Li, Fankang</creatorcontrib><creatorcontrib>Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV - Hybrid</collection><collection>OSTI.GOV</collection><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dadisman, Ryan</au><au>Shen, Jiazhou</au><au>Feng, Hao</au><au>Crow, Lowell</au><au>Jiang, Chenyang</au><au>Wang, Tianhao</au><au>Zhang, Yuxuan</au><au>Bilheux, Hassina</au><au>Parnell, Steven R.</au><au>Pynn, Roger</au><au>Li, Fankang</au><aucorp>Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and characterization of zero magnetic field chambers for high efficiency neutron polarization transport</atitle><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle><date>2019-10-01</date><risdate>2019</risdate><volume>940</volume><issue>C</issue><spage>174</spage><epage>180</epage><pages>174-180</pages><issn>0168-9002</issn><eissn>1872-9576</eissn><abstract>Several methods of polarized neutron scattering call for a zero magnetic field (ZF) region to reduce magnetic field integral aberrations while preserving the neutron polarization. Though the design for large angle neutron scattering has been presented in various places, the design characterization and tuning has not been discussed before. In this report, the tuning procedure will be discussed with both neutron polarization transport method and utilization of fluxgate magnetometers. As a tuning procedure, polarized neutrons are sensitive to any local field distortions along all trajectories within the beam, but the process is slow. With fluxgates, the entire beam region cannot be accessed simultaneously, but very fast and precise measurements can be made in accessible regions of interest. Consequently, we would like to benchmark the usage of fluxgates as a fast tuning probe compared with polarization measurements made with neutrons. Polarization transport results for tuned ZF chambers, up to 2.25 m in length, are presented.</abstract><cop>United States</cop><pub>Elsevier B.V</pub><doi>10.1016/j.nima.2019.05.092</doi><tpages>7</tpages><orcidid>https://orcid.org/0000000188590102</orcidid><orcidid>https://orcid.org/000000025212879X</orcidid><orcidid>https://orcid.org/0000000200831408</orcidid><orcidid>https://orcid.org/0000000185742449</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0168-9002 |
ispartof | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2019-10, Vol.940 (C), p.174-180 |
issn | 0168-9002 1872-9576 |
language | eng |
recordid | cdi_osti_scitechconnect_1542231 |
source | Elsevier ScienceDirect Journals Complete - AutoHoldings |
subjects | INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY Large-angle neutron scattering Larmor labeling Magnetic Wollaston prisms Polarization transport Small-angle neutron scattering Zero magnetic field |
title | Design and characterization of zero magnetic field chambers for high efficiency neutron polarization transport |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T12%3A27%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20characterization%20of%20zero%20magnetic%20field%20chambers%20for%20high%20efficiency%20neutron%20polarization%20transport&rft.jtitle=Nuclear%20instruments%20&%20methods%20in%20physics%20research.%20Section%20A,%20Accelerators,%20spectrometers,%20detectors%20and%20associated%20equipment&rft.au=Dadisman,%20Ryan&rft.aucorp=Oak%20Ridge%20National%20Lab.%20(ORNL),%20Oak%20Ridge,%20TN%20(United%20States)&rft.date=2019-10-01&rft.volume=940&rft.issue=C&rft.spage=174&rft.epage=180&rft.pages=174-180&rft.issn=0168-9002&rft.eissn=1872-9576&rft_id=info:doi/10.1016/j.nima.2019.05.092&rft_dat=%3Celsevier_osti_%3ES0168900219307648%3C/elsevier_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S0168900219307648&rfr_iscdi=true |