Diamond detectors for high energy physics experiments

Beam test results of the radiation tolerance study of chemical vapour deposition (CVD) diamond against different particle species and energies is presented. We also present beam test results on the independence of signal size on incident particle rate in charged particle detectors based on un-irradi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of instrumentation 2018-01, Vol.13 (1), p.C01029-C01029
Hauptverfasser: Bäni, L., Alexopoulos, A., Artuso, M., Bachmair, F., Bartosik, M., Beacham, J., Beck, H., Bellini, V., Belyaev, V., Bentele, B., Berdermann, E., Bergonzo, P., Bes, A., Brom, J-M., Bruzzi, M., Cerv, M., Chiodini, G., Chren, D., Cindro, V., Claus, G., Collot, J., Cumalat, J., Dabrowski, A., D'Alessandro, R., Dauvergne, D., de Boer, W., Dorfer, C., Dünser, M., Eremin, V., Eusebi, R., Forcolin, G., Forneris, J., Frais-Kölbl, H., Gallin-Martel, L., Gallin-Martel, M.L., Gan, K.K., Gastal, M., Giroletti, C., Goffe, M., Goldstein, J., Golubev, A., Gorišek, A., Grigoriev, E., Grosse-Knetter, J., Grummer, A., Gui, B., Guthoff, M., Haughton, I., Hiti, B., Hits, D., Hoeferkamp, M., Hofmann, T., Hosslet, J., Hostachy, J-Y., Hügging, F., Hutton, C., Jansen, H., Janssen, J., Kagan, H., Kanxheri, K., Kasieczka, G., Kass, R., Kassel, F., Kis, M., Konovalov, V., Kramberger, G., Kuleshov, S., Lacoste, A., Lagomarsino, S., Giudice, A. Lo, Lukosi, E., Maazouzi, C., Mandic, I., Mathieu, C., Menichelli, M., Mikuž, M., Morozzi, A., Moss, J., Mountain, R., Murphy, S., Muškinja, M., Oh, A., Oliviero, P., Passeri, D., Pernegger, H., Perrino, R., Picollo, F., Pomorski, M., Potenza, R., Quadt, A., Re, A., Reichmann, M., Riley, G., Roe, S., Sanz, D., Scaringella, M., Schaefer, D., Schmidt, C.J., Schnetzer, S., Sciortino, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Beam test results of the radiation tolerance study of chemical vapour deposition (CVD) diamond against different particle species and energies is presented. We also present beam test results on the independence of signal size on incident particle rate in charged particle detectors based on un-irradiated and irradiated poly-crystalline CVD diamond over a range of particle fluxes from 2 kHz/cm2 to 10 MHz/cm2. The pulse height of the sensors was measured with readout electronics with a peaking time of 6 ns. In addition functionality of poly-crystalline CVD diamond 3D devices was demonstrated in beam tests and 3D diamond detectors are shown to be a promising technology for applications in future high luminosity experiments.
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/13/01/C01029