Vapor chambers with hydrophobic and biphilic evaporators in moderate to high heat flux applications

•Feasibility of concurrent reducing thermal resistance and enhancing CHF is studied.•Engineered surfaces are leveraged to fabricate vapor chambers.•One vapor chamber is fabricated by a combined hydrophobicity and hydrophilicity.•One vapor chamber is fabricated by a biphilic evaporator. Two new types...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied thermal engineering 2018-02, Vol.130 (C), p.83-92
Hauptverfasser: Shaeri, Mohammad Reza, Attinger, Daniel, Bonner, Richard W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 92
container_issue C
container_start_page 83
container_title Applied thermal engineering
container_volume 130
creator Shaeri, Mohammad Reza
Attinger, Daniel
Bonner, Richard W.
description •Feasibility of concurrent reducing thermal resistance and enhancing CHF is studied.•Engineered surfaces are leveraged to fabricate vapor chambers.•One vapor chamber is fabricated by a combined hydrophobicity and hydrophilicity.•One vapor chamber is fabricated by a biphilic evaporator. Two new types of vapor chambers were fabricated to investigate the influence of engineering the wettability of evaporators for possibility of simultaneously reducing the thermal resistances and increasing the critical heat flux (CHF). One vapor chamber was fabricated by pressing a hydrophilic screen mesh wick structure into a hydrophobic evaporator through support posts integral to the condenser portion of the vapor chamber. The second vapor chamber included a biphilic evaporator without an evaporator wick, as such, the superhydrophilic zone surrounding the central hydrophobic area directly above the heater provided the capillary forces. Despite their lower thermal performances compared with those of the baseline vapor chamber fabricated by sintering the hydrophilic copper particles onto a hydrophilic copper substrate, both novel vapor chambers exhibited promising performances, as such, the vapor chamber with a hydrophobic evaporator approached CHF at high heat fluxes around 105 W/cm2, and the one with a biphilic evaporator did not approach the incipience of CHF until 162 W/cm2. The mechanical contact between the screen mesh and the hydrophobic evaporator, and the patterning of the biphilic evaporator were identified as the key roles in thermal performances of the tested vapor chambers. Suggestions are given to improve the thermal performances of the proposed vapor chambers in this study. If successful, the fabrication cost of these vapor chambers will be reduced by skipping high-temperature sintering process on the evaporators, the method that is used to fabricate the commonly used sintered-powder vapor chambers.
doi_str_mv 10.1016/j.applthermaleng.2017.11.051
format Article
fullrecord <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1538003</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1359431117334762</els_id><sourcerecordid>2043252901</sourcerecordid><originalsourceid>FETCH-LOGICAL-c439t-4648f29ad4c111bf4f142775face8c4f56e38fe4b6650e552f83f8585b43f7553</originalsourceid><addsrcrecordid>eNqNkM1L7TAQxYso-Pk_BJ_b1kyTtLngRsQvENyo25CmE5tLb9OX5Orzv38p1407VzMDv3M4c4riAmgFFJrLdaXneUwDho0ecXqvagptBVBRAXvFEciWlaKhzX7emViVnAEcFscxrimFWrb8qDBvevaBmEFvOgyRfLo0kOGrD34efOcM0VNPOjcPbswHfiy0Tj6TbiIb32O-kCRPBveehagTseP2H1mCOaOT81M8LQ6sHiOefc-T4vXu9uXmoXx6vn-8uX4qDWerVPKGS1uvdM8NAHSWW-B12wqrDUrDrWiQSYu8axpBUYjaSmalkKLjzLZCsJPifOfrY3IqGpfQDMZPE5qkQDBJKcvQnx00B_93izGptd-GKedSNeWsFvWKQqaudpQJPsaAVs3BbXT4UkDV0r1aq5_dq6V7BaBy91l-t5NjfvfDYVjS4GSwd2EJ03v3O6P_esmWsA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2043252901</pqid></control><display><type>article</type><title>Vapor chambers with hydrophobic and biphilic evaporators in moderate to high heat flux applications</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Shaeri, Mohammad Reza ; Attinger, Daniel ; Bonner, Richard W.</creator><creatorcontrib>Shaeri, Mohammad Reza ; Attinger, Daniel ; Bonner, Richard W. ; Advanced Cooling Technologies, Inc., Lancaster, PA (United States)</creatorcontrib><description>•Feasibility of concurrent reducing thermal resistance and enhancing CHF is studied.•Engineered surfaces are leveraged to fabricate vapor chambers.•One vapor chamber is fabricated by a combined hydrophobicity and hydrophilicity.•One vapor chamber is fabricated by a biphilic evaporator. Two new types of vapor chambers were fabricated to investigate the influence of engineering the wettability of evaporators for possibility of simultaneously reducing the thermal resistances and increasing the critical heat flux (CHF). One vapor chamber was fabricated by pressing a hydrophilic screen mesh wick structure into a hydrophobic evaporator through support posts integral to the condenser portion of the vapor chamber. The second vapor chamber included a biphilic evaporator without an evaporator wick, as such, the superhydrophilic zone surrounding the central hydrophobic area directly above the heater provided the capillary forces. Despite their lower thermal performances compared with those of the baseline vapor chamber fabricated by sintering the hydrophilic copper particles onto a hydrophilic copper substrate, both novel vapor chambers exhibited promising performances, as such, the vapor chamber with a hydrophobic evaporator approached CHF at high heat fluxes around 105 W/cm2, and the one with a biphilic evaporator did not approach the incipience of CHF until 162 W/cm2. The mechanical contact between the screen mesh and the hydrophobic evaporator, and the patterning of the biphilic evaporator were identified as the key roles in thermal performances of the tested vapor chambers. Suggestions are given to improve the thermal performances of the proposed vapor chambers in this study. If successful, the fabrication cost of these vapor chambers will be reduced by skipping high-temperature sintering process on the evaporators, the method that is used to fabricate the commonly used sintered-powder vapor chambers.</description><identifier>ISSN: 1359-4311</identifier><identifier>EISSN: 1873-5606</identifier><identifier>DOI: 10.1016/j.applthermaleng.2017.11.051</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Biphilic ; Chambers ; Copper ; Critical heat flux ; Energy &amp; Fuels ; Engineering ; Evaporators ; Heat flux ; Heat transfer ; Hydrophilic ; Hydrophobic ; Mechanics ; Sintering ; Sintering (powder metallurgy) ; Substrates ; Temperature ; Thermal resistance ; Thermodynamics ; Vapor chamber ; Vapors ; Wettability</subject><ispartof>Applied thermal engineering, 2018-02, Vol.130 (C), p.83-92</ispartof><rights>2017 Elsevier Ltd</rights><rights>Copyright Elsevier BV Feb 5, 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c439t-4648f29ad4c111bf4f142775face8c4f56e38fe4b6650e552f83f8585b43f7553</citedby><cites>FETCH-LOGICAL-c439t-4648f29ad4c111bf4f142775face8c4f56e38fe4b6650e552f83f8585b43f7553</cites><orcidid>0000-0002-2382-1149 ; 0000000223821149</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.applthermaleng.2017.11.051$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/1538003$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Shaeri, Mohammad Reza</creatorcontrib><creatorcontrib>Attinger, Daniel</creatorcontrib><creatorcontrib>Bonner, Richard W.</creatorcontrib><creatorcontrib>Advanced Cooling Technologies, Inc., Lancaster, PA (United States)</creatorcontrib><title>Vapor chambers with hydrophobic and biphilic evaporators in moderate to high heat flux applications</title><title>Applied thermal engineering</title><description>•Feasibility of concurrent reducing thermal resistance and enhancing CHF is studied.•Engineered surfaces are leveraged to fabricate vapor chambers.•One vapor chamber is fabricated by a combined hydrophobicity and hydrophilicity.•One vapor chamber is fabricated by a biphilic evaporator. Two new types of vapor chambers were fabricated to investigate the influence of engineering the wettability of evaporators for possibility of simultaneously reducing the thermal resistances and increasing the critical heat flux (CHF). One vapor chamber was fabricated by pressing a hydrophilic screen mesh wick structure into a hydrophobic evaporator through support posts integral to the condenser portion of the vapor chamber. The second vapor chamber included a biphilic evaporator without an evaporator wick, as such, the superhydrophilic zone surrounding the central hydrophobic area directly above the heater provided the capillary forces. Despite their lower thermal performances compared with those of the baseline vapor chamber fabricated by sintering the hydrophilic copper particles onto a hydrophilic copper substrate, both novel vapor chambers exhibited promising performances, as such, the vapor chamber with a hydrophobic evaporator approached CHF at high heat fluxes around 105 W/cm2, and the one with a biphilic evaporator did not approach the incipience of CHF until 162 W/cm2. The mechanical contact between the screen mesh and the hydrophobic evaporator, and the patterning of the biphilic evaporator were identified as the key roles in thermal performances of the tested vapor chambers. Suggestions are given to improve the thermal performances of the proposed vapor chambers in this study. If successful, the fabrication cost of these vapor chambers will be reduced by skipping high-temperature sintering process on the evaporators, the method that is used to fabricate the commonly used sintered-powder vapor chambers.</description><subject>Biphilic</subject><subject>Chambers</subject><subject>Copper</subject><subject>Critical heat flux</subject><subject>Energy &amp; Fuels</subject><subject>Engineering</subject><subject>Evaporators</subject><subject>Heat flux</subject><subject>Heat transfer</subject><subject>Hydrophilic</subject><subject>Hydrophobic</subject><subject>Mechanics</subject><subject>Sintering</subject><subject>Sintering (powder metallurgy)</subject><subject>Substrates</subject><subject>Temperature</subject><subject>Thermal resistance</subject><subject>Thermodynamics</subject><subject>Vapor chamber</subject><subject>Vapors</subject><subject>Wettability</subject><issn>1359-4311</issn><issn>1873-5606</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNkM1L7TAQxYso-Pk_BJ_b1kyTtLngRsQvENyo25CmE5tLb9OX5Orzv38p1407VzMDv3M4c4riAmgFFJrLdaXneUwDho0ecXqvagptBVBRAXvFEciWlaKhzX7emViVnAEcFscxrimFWrb8qDBvevaBmEFvOgyRfLo0kOGrD34efOcM0VNPOjcPbswHfiy0Tj6TbiIb32O-kCRPBveehagTseP2H1mCOaOT81M8LQ6sHiOefc-T4vXu9uXmoXx6vn-8uX4qDWerVPKGS1uvdM8NAHSWW-B12wqrDUrDrWiQSYu8axpBUYjaSmalkKLjzLZCsJPifOfrY3IqGpfQDMZPE5qkQDBJKcvQnx00B_93izGptd-GKedSNeWsFvWKQqaudpQJPsaAVs3BbXT4UkDV0r1aq5_dq6V7BaBy91l-t5NjfvfDYVjS4GSwd2EJ03v3O6P_esmWsA</recordid><startdate>20180205</startdate><enddate>20180205</enddate><creator>Shaeri, Mohammad Reza</creator><creator>Attinger, Daniel</creator><creator>Bonner, Richard W.</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>OTOTI</scope><orcidid>https://orcid.org/0000-0002-2382-1149</orcidid><orcidid>https://orcid.org/0000000223821149</orcidid></search><sort><creationdate>20180205</creationdate><title>Vapor chambers with hydrophobic and biphilic evaporators in moderate to high heat flux applications</title><author>Shaeri, Mohammad Reza ; Attinger, Daniel ; Bonner, Richard W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c439t-4648f29ad4c111bf4f142775face8c4f56e38fe4b6650e552f83f8585b43f7553</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Biphilic</topic><topic>Chambers</topic><topic>Copper</topic><topic>Critical heat flux</topic><topic>Energy &amp; Fuels</topic><topic>Engineering</topic><topic>Evaporators</topic><topic>Heat flux</topic><topic>Heat transfer</topic><topic>Hydrophilic</topic><topic>Hydrophobic</topic><topic>Mechanics</topic><topic>Sintering</topic><topic>Sintering (powder metallurgy)</topic><topic>Substrates</topic><topic>Temperature</topic><topic>Thermal resistance</topic><topic>Thermodynamics</topic><topic>Vapor chamber</topic><topic>Vapors</topic><topic>Wettability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shaeri, Mohammad Reza</creatorcontrib><creatorcontrib>Attinger, Daniel</creatorcontrib><creatorcontrib>Bonner, Richard W.</creatorcontrib><creatorcontrib>Advanced Cooling Technologies, Inc., Lancaster, PA (United States)</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>OSTI.GOV</collection><jtitle>Applied thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shaeri, Mohammad Reza</au><au>Attinger, Daniel</au><au>Bonner, Richard W.</au><aucorp>Advanced Cooling Technologies, Inc., Lancaster, PA (United States)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Vapor chambers with hydrophobic and biphilic evaporators in moderate to high heat flux applications</atitle><jtitle>Applied thermal engineering</jtitle><date>2018-02-05</date><risdate>2018</risdate><volume>130</volume><issue>C</issue><spage>83</spage><epage>92</epage><pages>83-92</pages><issn>1359-4311</issn><eissn>1873-5606</eissn><abstract>•Feasibility of concurrent reducing thermal resistance and enhancing CHF is studied.•Engineered surfaces are leveraged to fabricate vapor chambers.•One vapor chamber is fabricated by a combined hydrophobicity and hydrophilicity.•One vapor chamber is fabricated by a biphilic evaporator. Two new types of vapor chambers were fabricated to investigate the influence of engineering the wettability of evaporators for possibility of simultaneously reducing the thermal resistances and increasing the critical heat flux (CHF). One vapor chamber was fabricated by pressing a hydrophilic screen mesh wick structure into a hydrophobic evaporator through support posts integral to the condenser portion of the vapor chamber. The second vapor chamber included a biphilic evaporator without an evaporator wick, as such, the superhydrophilic zone surrounding the central hydrophobic area directly above the heater provided the capillary forces. Despite their lower thermal performances compared with those of the baseline vapor chamber fabricated by sintering the hydrophilic copper particles onto a hydrophilic copper substrate, both novel vapor chambers exhibited promising performances, as such, the vapor chamber with a hydrophobic evaporator approached CHF at high heat fluxes around 105 W/cm2, and the one with a biphilic evaporator did not approach the incipience of CHF until 162 W/cm2. The mechanical contact between the screen mesh and the hydrophobic evaporator, and the patterning of the biphilic evaporator were identified as the key roles in thermal performances of the tested vapor chambers. Suggestions are given to improve the thermal performances of the proposed vapor chambers in this study. If successful, the fabrication cost of these vapor chambers will be reduced by skipping high-temperature sintering process on the evaporators, the method that is used to fabricate the commonly used sintered-powder vapor chambers.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.applthermaleng.2017.11.051</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-2382-1149</orcidid><orcidid>https://orcid.org/0000000223821149</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1359-4311
ispartof Applied thermal engineering, 2018-02, Vol.130 (C), p.83-92
issn 1359-4311
1873-5606
language eng
recordid cdi_osti_scitechconnect_1538003
source Elsevier ScienceDirect Journals Complete
subjects Biphilic
Chambers
Copper
Critical heat flux
Energy & Fuels
Engineering
Evaporators
Heat flux
Heat transfer
Hydrophilic
Hydrophobic
Mechanics
Sintering
Sintering (powder metallurgy)
Substrates
Temperature
Thermal resistance
Thermodynamics
Vapor chamber
Vapors
Wettability
title Vapor chambers with hydrophobic and biphilic evaporators in moderate to high heat flux applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T09%3A06%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Vapor%20chambers%20with%20hydrophobic%20and%20biphilic%20evaporators%20in%20moderate%20to%20high%20heat%20flux%20applications&rft.jtitle=Applied%20thermal%20engineering&rft.au=Shaeri,%20Mohammad%20Reza&rft.aucorp=Advanced%20Cooling%20Technologies,%20Inc.,%20Lancaster,%20PA%20(United%20States)&rft.date=2018-02-05&rft.volume=130&rft.issue=C&rft.spage=83&rft.epage=92&rft.pages=83-92&rft.issn=1359-4311&rft.eissn=1873-5606&rft_id=info:doi/10.1016/j.applthermaleng.2017.11.051&rft_dat=%3Cproquest_osti_%3E2043252901%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2043252901&rft_id=info:pmid/&rft_els_id=S1359431117334762&rfr_iscdi=true