Technique for insulated and non-insulated metal liner X-pinch radiography on a 1 MA pulsed power machine

Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2017-11, Vol.88 (11), p.113502-113502
Hauptverfasser: Atoyan, L., Shelkovenko, T. A., Pikuz, S. A., Hammer, D. A., Byvank, T., Greenly, J. B., Potter, W. M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 113502
container_issue 11
container_start_page 113502
container_title Review of scientific instruments
container_volume 88
creator Atoyan, L.
Shelkovenko, T. A.
Pikuz, S. A.
Hammer, D. A.
Byvank, T.
Greenly, J. B.
Potter, W. M.
description Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise time pulsed power generator, μm scale features were imaged in initially 16 μm thick Al foil cylindrical liners. Better resolution and contrast were obtained using an X-ray sensitive film than with image plate detectors because of the properties of the X-pinch X-ray source. We also discuss configuration variations that were made to the simple cylindrical liner geometry that appeared to maintain validity of the small-scale structure measurements while improving measurement quality.
doi_str_mv 10.1063/1.4989985
format Article
fullrecord <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1406389</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1971701931</sourcerecordid><originalsourceid>FETCH-LOGICAL-c445t-80421bae5104d7fca3909f953494d94a7c3f2ff2575a5c002079cbf37724a4243</originalsourceid><addsrcrecordid>eNp90U9LHDEUAPBQLHW1PfQLSNCLFcbmJZnN5ChiW0HxYqG3kM0kTmQmGZMZxW9vlt1WEGwugcfvPd4fhL4COQWyZN_hlMtGyqb-gBZAGlmJJWU7aEEI49VS8GYX7eV8T8qrAT6hXSpB1oyLBepuremCf5gtdjFhH_Lc68m2WIcWhxiq18hgJ93j3geb8J9q9MF0OOnWx7ukx-4Zx4A1Bnx9hse5zyVhjE-FDtp0Jecz-uh0CX_Z_vvo94-L2_Nf1dXNz8vzs6vKcF5PVUM4hZW2NRDeCmc0k0S6dbOSt5JrYZijztFa1Lo2hFAipFk5JgTlmlPO9tHhpm7Mk1fZ-KkMaGII1kwKeFlXIws63qAxxTJ6ntTgs7F9r4ONc1YgBQgCkkGhR2_ofZxTKCMoCrAkRFDKivq2USbFnJN1akx-0OlZAVHrGylQ2xsVe7CtOK8G2_6Tf49SwMkGrLvXk4_hv9XexY8xvUI1to69AF3XpXk</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2116007223</pqid></control><display><type>article</type><title>Technique for insulated and non-insulated metal liner X-pinch radiography on a 1 MA pulsed power machine</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Atoyan, L. ; Shelkovenko, T. A. ; Pikuz, S. A. ; Hammer, D. A. ; Byvank, T. ; Greenly, J. B. ; Potter, W. M.</creator><creatorcontrib>Atoyan, L. ; Shelkovenko, T. A. ; Pikuz, S. A. ; Hammer, D. A. ; Byvank, T. ; Greenly, J. B. ; Potter, W. M.</creatorcontrib><description>Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise time pulsed power generator, μm scale features were imaged in initially 16 μm thick Al foil cylindrical liners. Better resolution and contrast were obtained using an X-ray sensitive film than with image plate detectors because of the properties of the X-pinch X-ray source. We also discuss configuration variations that were made to the simple cylindrical liner geometry that appeared to maintain validity of the small-scale structure measurements while improving measurement quality.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.4989985</identifier><identifier>PMID: 29195347</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><subject>Broadband ; Foils ; Image contrast ; Linings ; Plates (structural members) ; Radiography ; Scientific apparatus &amp; instruments ; Structural stability ; X ray sources</subject><ispartof>Review of scientific instruments, 2017-11, Vol.88 (11), p.113502-113502</ispartof><rights>Author(s)</rights><rights>2017 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c445t-80421bae5104d7fca3909f953494d94a7c3f2ff2575a5c002079cbf37724a4243</citedby><cites>FETCH-LOGICAL-c445t-80421bae5104d7fca3909f953494d94a7c3f2ff2575a5c002079cbf37724a4243</cites><orcidid>0000-0002-6660-1816 ; 0000-0003-3956-6506 ; 0000-0002-6618-0580 ; 0000000266180580 ; 0000000266601816 ; 0000000339566506</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.4989985$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>230,314,780,784,794,885,4512,27924,27925,76384</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29195347$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/1406389$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Atoyan, L.</creatorcontrib><creatorcontrib>Shelkovenko, T. A.</creatorcontrib><creatorcontrib>Pikuz, S. A.</creatorcontrib><creatorcontrib>Hammer, D. A.</creatorcontrib><creatorcontrib>Byvank, T.</creatorcontrib><creatorcontrib>Greenly, J. B.</creatorcontrib><creatorcontrib>Potter, W. M.</creatorcontrib><title>Technique for insulated and non-insulated metal liner X-pinch radiography on a 1 MA pulsed power machine</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise time pulsed power generator, μm scale features were imaged in initially 16 μm thick Al foil cylindrical liners. Better resolution and contrast were obtained using an X-ray sensitive film than with image plate detectors because of the properties of the X-pinch X-ray source. We also discuss configuration variations that were made to the simple cylindrical liner geometry that appeared to maintain validity of the small-scale structure measurements while improving measurement quality.</description><subject>Broadband</subject><subject>Foils</subject><subject>Image contrast</subject><subject>Linings</subject><subject>Plates (structural members)</subject><subject>Radiography</subject><subject>Scientific apparatus &amp; instruments</subject><subject>Structural stability</subject><subject>X ray sources</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp90U9LHDEUAPBQLHW1PfQLSNCLFcbmJZnN5ChiW0HxYqG3kM0kTmQmGZMZxW9vlt1WEGwugcfvPd4fhL4COQWyZN_hlMtGyqb-gBZAGlmJJWU7aEEI49VS8GYX7eV8T8qrAT6hXSpB1oyLBepuremCf5gtdjFhH_Lc68m2WIcWhxiq18hgJ93j3geb8J9q9MF0OOnWx7ukx-4Zx4A1Bnx9hse5zyVhjE-FDtp0Jecz-uh0CX_Z_vvo94-L2_Nf1dXNz8vzs6vKcF5PVUM4hZW2NRDeCmc0k0S6dbOSt5JrYZijztFa1Lo2hFAipFk5JgTlmlPO9tHhpm7Mk1fZ-KkMaGII1kwKeFlXIws63qAxxTJ6ntTgs7F9r4ONc1YgBQgCkkGhR2_ofZxTKCMoCrAkRFDKivq2USbFnJN1akx-0OlZAVHrGylQ2xsVe7CtOK8G2_6Tf49SwMkGrLvXk4_hv9XexY8xvUI1to69AF3XpXk</recordid><startdate>201711</startdate><enddate>201711</enddate><creator>Atoyan, L.</creator><creator>Shelkovenko, T. A.</creator><creator>Pikuz, S. A.</creator><creator>Hammer, D. A.</creator><creator>Byvank, T.</creator><creator>Greenly, J. B.</creator><creator>Potter, W. M.</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope><scope>7X8</scope><scope>OTOTI</scope><orcidid>https://orcid.org/0000-0002-6660-1816</orcidid><orcidid>https://orcid.org/0000-0003-3956-6506</orcidid><orcidid>https://orcid.org/0000-0002-6618-0580</orcidid><orcidid>https://orcid.org/0000000266180580</orcidid><orcidid>https://orcid.org/0000000266601816</orcidid><orcidid>https://orcid.org/0000000339566506</orcidid></search><sort><creationdate>201711</creationdate><title>Technique for insulated and non-insulated metal liner X-pinch radiography on a 1 MA pulsed power machine</title><author>Atoyan, L. ; Shelkovenko, T. A. ; Pikuz, S. A. ; Hammer, D. A. ; Byvank, T. ; Greenly, J. B. ; Potter, W. M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c445t-80421bae5104d7fca3909f953494d94a7c3f2ff2575a5c002079cbf37724a4243</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Broadband</topic><topic>Foils</topic><topic>Image contrast</topic><topic>Linings</topic><topic>Plates (structural members)</topic><topic>Radiography</topic><topic>Scientific apparatus &amp; instruments</topic><topic>Structural stability</topic><topic>X ray sources</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Atoyan, L.</creatorcontrib><creatorcontrib>Shelkovenko, T. A.</creatorcontrib><creatorcontrib>Pikuz, S. A.</creatorcontrib><creatorcontrib>Hammer, D. A.</creatorcontrib><creatorcontrib>Byvank, T.</creatorcontrib><creatorcontrib>Greenly, J. B.</creatorcontrib><creatorcontrib>Potter, W. M.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><collection>OSTI.GOV</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Atoyan, L.</au><au>Shelkovenko, T. A.</au><au>Pikuz, S. A.</au><au>Hammer, D. A.</au><au>Byvank, T.</au><au>Greenly, J. B.</au><au>Potter, W. M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Technique for insulated and non-insulated metal liner X-pinch radiography on a 1 MA pulsed power machine</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2017-11</date><risdate>2017</risdate><volume>88</volume><issue>11</issue><spage>113502</spage><epage>113502</epage><pages>113502-113502</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise time pulsed power generator, μm scale features were imaged in initially 16 μm thick Al foil cylindrical liners. Better resolution and contrast were obtained using an X-ray sensitive film than with image plate detectors because of the properties of the X-pinch X-ray source. We also discuss configuration variations that were made to the simple cylindrical liner geometry that appeared to maintain validity of the small-scale structure measurements while improving measurement quality.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>29195347</pmid><doi>10.1063/1.4989985</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0002-6660-1816</orcidid><orcidid>https://orcid.org/0000-0003-3956-6506</orcidid><orcidid>https://orcid.org/0000-0002-6618-0580</orcidid><orcidid>https://orcid.org/0000000266180580</orcidid><orcidid>https://orcid.org/0000000266601816</orcidid><orcidid>https://orcid.org/0000000339566506</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2017-11, Vol.88 (11), p.113502-113502
issn 0034-6748
1089-7623
language eng
recordid cdi_osti_scitechconnect_1406389
source AIP Journals Complete; Alma/SFX Local Collection
subjects Broadband
Foils
Image contrast
Linings
Plates (structural members)
Radiography
Scientific apparatus & instruments
Structural stability
X ray sources
title Technique for insulated and non-insulated metal liner X-pinch radiography on a 1 MA pulsed power machine
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T09%3A51%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Technique%20for%20insulated%20and%20non-insulated%20metal%20liner%20X-pinch%20radiography%20on%20a%201%20MA%20pulsed%20power%20machine&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Atoyan,%20L.&rft.date=2017-11&rft.volume=88&rft.issue=11&rft.spage=113502&rft.epage=113502&rft.pages=113502-113502&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.4989985&rft_dat=%3Cproquest_osti_%3E1971701931%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2116007223&rft_id=info:pmid/29195347&rfr_iscdi=true