Short and long-term sensitivity of lab-scale thermocline based thermal storage to flow disturbances

Molten-salt thermocline-based systems are a low-cost option for single-tank thermal energy storage in concentrated solar power plants. Due to the high variability in solar energy availability, these energy storage devices are subject to transient heat loads during charging that can affect the storag...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied thermal engineering 2016-10, Vol.109 (PB), p.936-948
Hauptverfasser: Hatte, Sandeep, Mira-Hernández, Carolina, Advaith, S., Tinaikar, Aashay, Chetia, Utpal Kumar, Manu, K.V., Chattopadhyay, Kamanio, Weibel, Justin A., Garimella, Suresh V., Srinivasan, Vinod, Basu, Saptarshi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 948
container_issue PB
container_start_page 936
container_title Applied thermal engineering
container_volume 109
creator Hatte, Sandeep
Mira-Hernández, Carolina
Advaith, S.
Tinaikar, Aashay
Chetia, Utpal Kumar
Manu, K.V.
Chattopadhyay, Kamanio
Weibel, Justin A.
Garimella, Suresh V.
Srinivasan, Vinod
Basu, Saptarshi
description Molten-salt thermocline-based systems are a low-cost option for single-tank thermal energy storage in concentrated solar power plants. Due to the high variability in solar energy availability, these energy storage devices are subject to transient heat loads during charging that can affect the storage efficiency. Numerical simulations were conducted to analyze the stability characteristics of a lab-scale thermocline tank subject to a flow disturbance during charging under different operating temperatures. The charging process was first simulated at a constant Reynolds number for three different Atwood numbers; a stably stratified fluid layer develops inside the storage tank in all cases. A flow disturbance was then introduced at the inlet of the stratified thermocline tank by inserting colder fluid for a short period of time. The disturbance interacts with the thermocline and causes oscillations and mixing. The thermocline oscillations are under-damped and lead to an increase in thermocline region thickness. The transient behavior of the thermocline and the decay rate in its oscillations were analyzed; the damping time depends on the Atwood number. The persistence of flow disturbance effects during long-term cyclical operation was also investigated. Several charge/discharge cycles were simulated at constant Reynolds number to obtain a time-periodic thermal response for each Atwood number. The characteristic flow disturbance was introduced at the inlet during a single charging process, and the thermocline region was observed during several subsequent charge/discharge cycles to assess the long-term temporal attenuation of the disturbance. The thermocline almost fully recovers to the time-periodic behavior after a single cycle.
doi_str_mv 10.1016/j.applthermaleng.2016.04.138
format Article
fullrecord <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1397807</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1359431116306263</els_id><sourcerecordid>S1359431116306263</sourcerecordid><originalsourceid>FETCH-LOGICAL-c522t-cc2185fc5944bf098fa7664178f661a0001155aebf72af3101e9dfbf870602cb3</originalsourceid><addsrcrecordid>eNqNkE1PAyEYhDloYv34D8R43RV22YVNvJjGqkkTD-qZsOxLS7OFBrCm_17W9uLNE8mbmWeYQeiOkpIS2t5vSrXbjWkNYatGcKuyyteSsJLW4gzNaN10BaspvUCXMW4IoZXgbIb0-9qHhJUb8OjdqkjZjyO4aJPd23TA3uBR9UXUmYp_8V6P1gHuVYQBnwJxTD6oVVZ4bEb_jQcb01foldMQr9G5UWOEm9N7hT4XTx_zl2L59vw6f1wWuqmqVGhdUdEY3XSM9YZ0wijetoxyYdqWKpL_TJtGQW94pUydW0M3mN4ITlpS6b6-QrdHro_JyqhtAr3W3jnQSdK644LwLHo4inTwMQYwchfsVoWDpEROS8qN_LuknJaUhGWEyPbF0Q65yN5CmHIgtxxsmGIGb_8H-gHtU4lJ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Short and long-term sensitivity of lab-scale thermocline based thermal storage to flow disturbances</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Hatte, Sandeep ; Mira-Hernández, Carolina ; Advaith, S. ; Tinaikar, Aashay ; Chetia, Utpal Kumar ; Manu, K.V. ; Chattopadhyay, Kamanio ; Weibel, Justin A. ; Garimella, Suresh V. ; Srinivasan, Vinod ; Basu, Saptarshi</creator><creatorcontrib>Hatte, Sandeep ; Mira-Hernández, Carolina ; Advaith, S. ; Tinaikar, Aashay ; Chetia, Utpal Kumar ; Manu, K.V. ; Chattopadhyay, Kamanio ; Weibel, Justin A. ; Garimella, Suresh V. ; Srinivasan, Vinod ; Basu, Saptarshi</creatorcontrib><description>Molten-salt thermocline-based systems are a low-cost option for single-tank thermal energy storage in concentrated solar power plants. Due to the high variability in solar energy availability, these energy storage devices are subject to transient heat loads during charging that can affect the storage efficiency. Numerical simulations were conducted to analyze the stability characteristics of a lab-scale thermocline tank subject to a flow disturbance during charging under different operating temperatures. The charging process was first simulated at a constant Reynolds number for three different Atwood numbers; a stably stratified fluid layer develops inside the storage tank in all cases. A flow disturbance was then introduced at the inlet of the stratified thermocline tank by inserting colder fluid for a short period of time. The disturbance interacts with the thermocline and causes oscillations and mixing. The thermocline oscillations are under-damped and lead to an increase in thermocline region thickness. The transient behavior of the thermocline and the decay rate in its oscillations were analyzed; the damping time depends on the Atwood number. The persistence of flow disturbance effects during long-term cyclical operation was also investigated. Several charge/discharge cycles were simulated at constant Reynolds number to obtain a time-periodic thermal response for each Atwood number. The characteristic flow disturbance was introduced at the inlet during a single charging process, and the thermocline region was observed during several subsequent charge/discharge cycles to assess the long-term temporal attenuation of the disturbance. The thermocline almost fully recovers to the time-periodic behavior after a single cycle.</description><identifier>ISSN: 1359-4311</identifier><identifier>DOI: 10.1016/j.applthermaleng.2016.04.138</identifier><language>eng</language><publisher>United Kingdom: Elsevier Ltd</publisher><subject>Rayleigh–Taylor instability ; Solar thermal energy storage ; Thermal storage efficiency ; Thermocline</subject><ispartof>Applied thermal engineering, 2016-10, Vol.109 (PB), p.936-948</ispartof><rights>2016 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c522t-cc2185fc5944bf098fa7664178f661a0001155aebf72af3101e9dfbf870602cb3</citedby><cites>FETCH-LOGICAL-c522t-cc2185fc5944bf098fa7664178f661a0001155aebf72af3101e9dfbf870602cb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.applthermaleng.2016.04.138$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3548,27922,27923,45993</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/1397807$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Hatte, Sandeep</creatorcontrib><creatorcontrib>Mira-Hernández, Carolina</creatorcontrib><creatorcontrib>Advaith, S.</creatorcontrib><creatorcontrib>Tinaikar, Aashay</creatorcontrib><creatorcontrib>Chetia, Utpal Kumar</creatorcontrib><creatorcontrib>Manu, K.V.</creatorcontrib><creatorcontrib>Chattopadhyay, Kamanio</creatorcontrib><creatorcontrib>Weibel, Justin A.</creatorcontrib><creatorcontrib>Garimella, Suresh V.</creatorcontrib><creatorcontrib>Srinivasan, Vinod</creatorcontrib><creatorcontrib>Basu, Saptarshi</creatorcontrib><title>Short and long-term sensitivity of lab-scale thermocline based thermal storage to flow disturbances</title><title>Applied thermal engineering</title><description>Molten-salt thermocline-based systems are a low-cost option for single-tank thermal energy storage in concentrated solar power plants. Due to the high variability in solar energy availability, these energy storage devices are subject to transient heat loads during charging that can affect the storage efficiency. Numerical simulations were conducted to analyze the stability characteristics of a lab-scale thermocline tank subject to a flow disturbance during charging under different operating temperatures. The charging process was first simulated at a constant Reynolds number for three different Atwood numbers; a stably stratified fluid layer develops inside the storage tank in all cases. A flow disturbance was then introduced at the inlet of the stratified thermocline tank by inserting colder fluid for a short period of time. The disturbance interacts with the thermocline and causes oscillations and mixing. The thermocline oscillations are under-damped and lead to an increase in thermocline region thickness. The transient behavior of the thermocline and the decay rate in its oscillations were analyzed; the damping time depends on the Atwood number. The persistence of flow disturbance effects during long-term cyclical operation was also investigated. Several charge/discharge cycles were simulated at constant Reynolds number to obtain a time-periodic thermal response for each Atwood number. The characteristic flow disturbance was introduced at the inlet during a single charging process, and the thermocline region was observed during several subsequent charge/discharge cycles to assess the long-term temporal attenuation of the disturbance. The thermocline almost fully recovers to the time-periodic behavior after a single cycle.</description><subject>Rayleigh–Taylor instability</subject><subject>Solar thermal energy storage</subject><subject>Thermal storage efficiency</subject><subject>Thermocline</subject><issn>1359-4311</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqNkE1PAyEYhDloYv34D8R43RV22YVNvJjGqkkTD-qZsOxLS7OFBrCm_17W9uLNE8mbmWeYQeiOkpIS2t5vSrXbjWkNYatGcKuyyteSsJLW4gzNaN10BaspvUCXMW4IoZXgbIb0-9qHhJUb8OjdqkjZjyO4aJPd23TA3uBR9UXUmYp_8V6P1gHuVYQBnwJxTD6oVVZ4bEb_jQcb01foldMQr9G5UWOEm9N7hT4XTx_zl2L59vw6f1wWuqmqVGhdUdEY3XSM9YZ0wijetoxyYdqWKpL_TJtGQW94pUydW0M3mN4ITlpS6b6-QrdHro_JyqhtAr3W3jnQSdK644LwLHo4inTwMQYwchfsVoWDpEROS8qN_LuknJaUhGWEyPbF0Q65yN5CmHIgtxxsmGIGb_8H-gHtU4lJ</recordid><startdate>20161025</startdate><enddate>20161025</enddate><creator>Hatte, Sandeep</creator><creator>Mira-Hernández, Carolina</creator><creator>Advaith, S.</creator><creator>Tinaikar, Aashay</creator><creator>Chetia, Utpal Kumar</creator><creator>Manu, K.V.</creator><creator>Chattopadhyay, Kamanio</creator><creator>Weibel, Justin A.</creator><creator>Garimella, Suresh V.</creator><creator>Srinivasan, Vinod</creator><creator>Basu, Saptarshi</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>20161025</creationdate><title>Short and long-term sensitivity of lab-scale thermocline based thermal storage to flow disturbances</title><author>Hatte, Sandeep ; Mira-Hernández, Carolina ; Advaith, S. ; Tinaikar, Aashay ; Chetia, Utpal Kumar ; Manu, K.V. ; Chattopadhyay, Kamanio ; Weibel, Justin A. ; Garimella, Suresh V. ; Srinivasan, Vinod ; Basu, Saptarshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c522t-cc2185fc5944bf098fa7664178f661a0001155aebf72af3101e9dfbf870602cb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Rayleigh–Taylor instability</topic><topic>Solar thermal energy storage</topic><topic>Thermal storage efficiency</topic><topic>Thermocline</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hatte, Sandeep</creatorcontrib><creatorcontrib>Mira-Hernández, Carolina</creatorcontrib><creatorcontrib>Advaith, S.</creatorcontrib><creatorcontrib>Tinaikar, Aashay</creatorcontrib><creatorcontrib>Chetia, Utpal Kumar</creatorcontrib><creatorcontrib>Manu, K.V.</creatorcontrib><creatorcontrib>Chattopadhyay, Kamanio</creatorcontrib><creatorcontrib>Weibel, Justin A.</creatorcontrib><creatorcontrib>Garimella, Suresh V.</creatorcontrib><creatorcontrib>Srinivasan, Vinod</creatorcontrib><creatorcontrib>Basu, Saptarshi</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Applied thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hatte, Sandeep</au><au>Mira-Hernández, Carolina</au><au>Advaith, S.</au><au>Tinaikar, Aashay</au><au>Chetia, Utpal Kumar</au><au>Manu, K.V.</au><au>Chattopadhyay, Kamanio</au><au>Weibel, Justin A.</au><au>Garimella, Suresh V.</au><au>Srinivasan, Vinod</au><au>Basu, Saptarshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Short and long-term sensitivity of lab-scale thermocline based thermal storage to flow disturbances</atitle><jtitle>Applied thermal engineering</jtitle><date>2016-10-25</date><risdate>2016</risdate><volume>109</volume><issue>PB</issue><spage>936</spage><epage>948</epage><pages>936-948</pages><issn>1359-4311</issn><abstract>Molten-salt thermocline-based systems are a low-cost option for single-tank thermal energy storage in concentrated solar power plants. Due to the high variability in solar energy availability, these energy storage devices are subject to transient heat loads during charging that can affect the storage efficiency. Numerical simulations were conducted to analyze the stability characteristics of a lab-scale thermocline tank subject to a flow disturbance during charging under different operating temperatures. The charging process was first simulated at a constant Reynolds number for three different Atwood numbers; a stably stratified fluid layer develops inside the storage tank in all cases. A flow disturbance was then introduced at the inlet of the stratified thermocline tank by inserting colder fluid for a short period of time. The disturbance interacts with the thermocline and causes oscillations and mixing. The thermocline oscillations are under-damped and lead to an increase in thermocline region thickness. The transient behavior of the thermocline and the decay rate in its oscillations were analyzed; the damping time depends on the Atwood number. The persistence of flow disturbance effects during long-term cyclical operation was also investigated. Several charge/discharge cycles were simulated at constant Reynolds number to obtain a time-periodic thermal response for each Atwood number. The characteristic flow disturbance was introduced at the inlet during a single charging process, and the thermocline region was observed during several subsequent charge/discharge cycles to assess the long-term temporal attenuation of the disturbance. The thermocline almost fully recovers to the time-periodic behavior after a single cycle.</abstract><cop>United Kingdom</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.applthermaleng.2016.04.138</doi><tpages>13</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1359-4311
ispartof Applied thermal engineering, 2016-10, Vol.109 (PB), p.936-948
issn 1359-4311
language eng
recordid cdi_osti_scitechconnect_1397807
source ScienceDirect Journals (5 years ago - present)
subjects Rayleigh–Taylor instability
Solar thermal energy storage
Thermal storage efficiency
Thermocline
title Short and long-term sensitivity of lab-scale thermocline based thermal storage to flow disturbances
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T23%3A58%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Short%20and%20long-term%20sensitivity%20of%20lab-scale%20thermocline%20based%20thermal%20storage%20to%20flow%20disturbances&rft.jtitle=Applied%20thermal%20engineering&rft.au=Hatte,%20Sandeep&rft.date=2016-10-25&rft.volume=109&rft.issue=PB&rft.spage=936&rft.epage=948&rft.pages=936-948&rft.issn=1359-4311&rft_id=info:doi/10.1016/j.applthermaleng.2016.04.138&rft_dat=%3Celsevier_osti_%3ES1359431116306263%3C/elsevier_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=S1359431116306263&rfr_iscdi=true